A combined automatic MR OAR contouring and synthetic CT solution for prostate MR-only radiotherapy

被引:0
|
作者
Wyatt, Jonathan J. [1 ,2 ]
Kaushik, Sandeep [3 ,4 ]
Cozzini, Cristina [3 ]
Kolozsvari, Bernadett [5 ]
Deak-Karancsi, Borbala [5 ]
Pearson, Rachel A. [1 ,2 ]
Petit, Steven [6 ]
Capala, Marta [6 ]
Hernandez-Tamames, Juan A. [7 ]
Hideghety, Katalin [8 ]
Maxwell, Ross J. [1 ]
Rusko, Laszlo [5 ]
Wiesinger, Florian [3 ]
McCallum, Hazel M. [1 ,2 ]
机构
[1] Newcastle Univ, Translat & Clin Res Inst, Newcastle Upon Tyne, Tyne & Wear, England
[2] Newcastle Upon Tyne Hosp NHS Fdn Trust, Northern Ctr Canc Care, Newcastle Upon Tyne, Tyne & Wear, England
[3] GE Healthcare, Res, Munich, Germany
[4] Univ Zurich, Dept Quantitat Biomed, Zurich, Switzerland
[5] GE Healthcare, Res, Budapest, Hungary
[6] Erasmus MC Canc Inst, Dept Radiotherapy, Rotterdam, Netherlands
[7] Erasmus MC, Dept Radiol & Nucl Med, Rotterdam, Netherlands
[8] Univ Szeged, Dept Oncotherapy, Szeged, Hungary
关键词
MR-only; prostate; synthetic CT;
D O I
暂无
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
2967
引用
收藏
页码:S3144 / S3147
页数:5
相关论文
共 50 条
  • [31] Dosimetric evaluation of synthetic CT image generated using a neural network for MR-only brain radiotherapy
    Tang, Bin
    Wu, Fan
    Fu, Yuchuan
    Wang, Xianliang
    Wang, Pei
    Orlandini, Lucia Clara
    Li, Jie
    Hou, Qing
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2021, 22 (03): : 55 - 62
  • [32] Dosimetric Evaluation of Dose Calculation Uncertainties for MR-Only Approaches in Prostate MR-Guided Radiotherapy
    Coric, Ivan
    Shreshtha, Kumar
    Roque, Thais
    Paragios, Nikos
    Gani, Cihan
    Zips, Daniel
    Thorwarth, Daniela
    Nachbar, Marcel
    FRONTIERS IN PHYSICS, 2022, 10
  • [33] Bony structure enhanced synthetic CT generation using Dixon sequences for pelvis MR-only radiotherapy
    Liang, Xiao
    Yen, Allen
    Bai, Ti
    Godley, Andrew
    Shen, Chenyang
    Wu, Junjie
    Meng, Boyu
    Lin, Mu-Han
    Medin, Paul
    Yan, Yulong
    Owrangi, Amir
    Desai, Neil
    Hannan, Raquibul
    Garant, Aurelie
    Jiang, Steve
    Deng, Jie
    MEDICAL PHYSICS, 2023, 50 (12) : 7368 - 7382
  • [34] Evaluation of first 20 patients treated with MR-Only prostate radiotherapy with MR-CBCT matching
    Wyatt, J.
    Pearson, R. A.
    Frew, J.
    Walker, C.
    Richmond, N.
    Wilkinson, M.
    Wilkes, K.
    Driver, S.
    West, S.
    Pilling, K.
    Brooks, R. L.
    Ainslie, D.
    Wilkins, E.
    McCallum, H. M.
    RADIOTHERAPY AND ONCOLOGY, 2020, 152 : S265 - S265
  • [35] Dosimetric Evaluation of Magnetic Resonance-Generated Synthetic CT for MR-Only Rectal Cancer Radiotherapy
    Wang, H.
    Du, K.
    Qu, J.
    Chandarana, H.
    Das, I.
    MEDICAL PHYSICS, 2017, 44 (06)
  • [36] Synthetic CT reconstruction using a deep spatial pyramid convolutional framework for MR-only breast radiotherapy
    Olberg, Sven
    Zhang, Hao
    Kennedy, William R.
    Chun, Jaehee
    Rodriguez, Vivian
    Zoberi, Imran
    Thomas, Maria A.
    Kim, Jin Sung
    Mutic, Sasa
    Green, Olga L.
    Park, Justin C.
    MEDICAL PHYSICS, 2019, 46 (09) : 4135 - 4147
  • [37] Dosimetric consistency between MR-only and deformed CT for MR-guided online adaptive radiotherapy
    Santurio, G. Valdes
    Edmund, J.
    Nousiainen, K. I.
    RADIOTHERAPY AND ONCOLOGY, 2022, 170 : S693 - S694
  • [38] Dosimetric Evaluation of Multi-sequence MR Image-based Synthetic CT Generation for Head and Neck MR-only Radiotherapy
    Li, Y.
    Qi, M.
    Wu, A.
    Zhou, L.
    Deng, X.
    Song, T.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2020, 108 (03): : E291 - E292
  • [39] IMPROVING SPATIAL ACCURACY IN EXTERNAL RADIOTHERAPY OF THE PROSTATE - INVESTIGATION OF A MR-ONLY WORKFLOW
    Nyholm, T.
    Karlsson, M.
    Karlsson, M.
    Zackrisson, B.
    RADIOTHERAPY AND ONCOLOGY, 2009, 92 : S181 - S181
  • [40] Brain MR-Only Using a Hybrid CT
    Paulson, E. S.
    Eliason, A.
    Boyd, Z.
    Mickevicius, N.
    Prah, D. E.
    Bovi, J. A.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2017, 99 (02): : E709 - E709