Investigation of heat and humidity regulation in air-to-air thermoelectric air conditioner with large cooling capacity

被引:0
|
作者
Zhang, Wenqian [1 ]
Liu, Zun [1 ]
Wang, Yunyi [1 ]
Chu, Leyao [1 ]
Shen, Limei [1 ]
机构
[1] Huazhong Univ Sci & Technol, Sch Energy & Power Engn, Wuhan 430074, Peoples R China
基金
中国国家自然科学基金;
关键词
Air-to-air heat transfer TEAC; Thermoelectric cooling; Heat and humidity regulation; Sensitivity analysis; PERFORMANCE;
D O I
10.1016/j.applthermaleng.2025.125944
中图分类号
O414.1 [热力学];
学科分类号
摘要
Thermoelectric Air Conditioner (TEAC) has gained increasing attention in recent years and has started to become a new design direction for large cooling capacity scenarios. This paper presents the investigation of temperature and humidity in air-to-air TEAC with large cooling capacity. The simulation model of thermoelectric cooling unit has been established to analyze the impact of temperature and humidity on the cooling performance. The results show that the impact of temperature on the cooling performance is linear, with an average increase of 32.6 W in Q(c) for every 2 degrees C increases in indoor temperature, and an average decrease of 23.0 W in Q(c) for every 2 degrees C increases in outdoor temperature. Moreover, the sensitivity of the cold-side outlet air temperature to indoor temperature is 5.7 times higher than the sensitivity to outdoor temperature. In contrast, the influence of humidity on cooling performance is nonlinear and complex. When humidity is low, the cooling performance is hardly affected. However, when humidity increases from 40 % to 60 %, due to the air condensation process, the cooling performance improves significantly, with an average increase of 50.8 W in Q(c). Also, the sensitivity of the outlet air temperature to high humidity air is significantly higher than that to low humidity air. Under various working conditions, by adjusting the current, the outlet air temperature of the TEAC can be maintained at 16 degrees C-20 degrees C, all of which meet the thermal comfort standard. Furthermore, the Q(c) of the system can reach similar to 2500 W under rated working condition and the COP is as high as 2.397 under low temperature condition. This study analyzes the heat and mass transfer and investigates the practicality of TEAC in a variety of complex and changing scenarios, providing a vital reference for the broader application of thermoelectric cooling technology.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] AIR-TO-AIR HEAT-EXCHANGERS FOR HOUSES
    SHURCLIFF, WA
    ANNUAL REVIEW OF ENERGY, 1988, 13 : 1 - 22
  • [22] AIR-TO-AIR HEAT-EXCHANGER PERFORMANCE
    DROST, MK
    ENERGY AND BUILDINGS, 1993, 19 (03) : 215 - 220
  • [23] Heat recovery in an air-conditioning system with air-to-air heat exchanger
    Papakostas, K.T.
    Kiosis, G.C.
    International Journal of Sustainable Energy, 2015, 34 : 221 - 231
  • [24] AIR CONDITIONER COOLING AND HEATING CAPACITY AND AIRFLOW CALCULATED BY COMPUTER
    SPOFFORD, WA
    ASHRAE JOURNAL, 1969, 11 (01): : 63 - &
  • [25] Experimental investigation on hybrid of thermoelectric air conditioner and water heater
    Du, H. L.
    Qi, Z. H.
    Kuang, X.
    Li, H. M.
    CRYOGENICS AND REFRIGERATION, PROCEEDINGS, 2008, : 432 - 436
  • [26] Investigation of audible sound waves on the heat transfer characteristics of air-to-air heat exchange systems
    Guo, Chang
    Wei, Wei
    Wang, Cong
    Liu, Zhigang
    Guo, Lin
    Gao, Ming
    PHYSICS OF FLUIDS, 2023, 35 (03)
  • [27] AIR-TO-AIR HEAT-EXCHANGERS AND THE INDOOR ENVIRONMENT
    VINE, E
    ENERGY, 1987, 12 (12) : 1209 - 1215
  • [28] Experimental investigation on thermoelectric air conditioner driven by solar cells
    Xu, Lizhen
    Li, Yan
    Qin, Feng
    Chen, Changhe
    PROCEEDINGS OF ISES SOLAR WORLD CONGRESS 2007: SOLAR ENERGY AND HUMAN SETTLEMENT, VOLS I-V, 2007, : 1914 - 1918
  • [29] Performance evaluation of a compact air-to-air heat pump
    Kent, EF
    ENERGY CONVERSION AND MANAGEMENT, 1997, 38 (04) : 341 - 345
  • [30] AIR-TO-AIR HEAT PUMPS: THE PROS AND CONS.
    Roth, Richard W.
    Energy Management Technology, 1986, 10 (01): : 20 - 22