Protective biomechanical and histological changes in the false lumen wall in chronic type B aortic dissection

被引:0
|
作者
Dong, Hai [1 ,2 ]
Liu, Minliang [3 ,4 ]
Cebull, Hannah L. [5 ]
Chhabra, Arshiya [2 ]
Zhou, Yumeng [2 ]
Piccinelli, Marina [5 ]
Oshinski, John N. [5 ]
Elefteriades, John A. [3 ,4 ,6 ]
Gleason, Rudolph L. [2 ]
Leshnower, Bradley G. [1 ]
机构
[1] Emory Univ, Sch Med, Div Cardiothorac Surg, Carlyle Fraser Cardiothorac Res Lab, 1365 Clifton Rd,Suite A 2213, Atlanta, GA 30322 USA
[2] Emory Univ, Sch Med, Dept Radiol & Imaging Sci, Atlanta, GA 30322 USA
[3] Georgia Inst Technol, George W Woodruff Sch Mech Engn, Atlanta, GA USA
[4] Georgia Inst Technol, Wallace H Coulter Dept Biomed Engn, Atlanta, GA USA
[5] Texas Tech Univ, Dept Mech Engn, Lubbock, TX USA
[6] Yale Univ, Yale New Haven Hosp, Aort Inst, Div Cardiac Surg,Sch Med, New Haven, CT USA
来源
JTCVS OPEN | 2025年 / 23卷
基金
美国国家卫生研究院;
关键词
aortic dissection; false lumen wall; biomechanical stiffness; histological analysis; COLLAGEN-FIBERS; THORACIC AORTA; ANEURYSM;
D O I
10.1016/j.xjon.2024.11.012
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: The outer false lumen wall (FLW) changes from thin/compliant to thick/ rigid as aortic dissection transitions from the acute to chronic phase. This study investigates biomechanical stiffness and histological changes of the FLW as the dissected aorta ages. Methods: The free outer FLW from human tissue was analyzed from chronic type B dissection (chronic-FLW) n = 10, acute type A dissection (acute-FLW) n = 10, and transplant donor descending aorta that was manually peeled into 2 layers (controlFLW) n = 17. Biaxial tension testing in the longitudinal and circumferential directions was performed and stress-strain curves were obtained. A lower and higher tangent modulus was determined to assess stiffness. Quantification of collagen and elastin was performed by calculating the fibers' volume fraction from Z-stack scans. Results: The higher tangent modulus of chronic-FLW is larger (P < .01) than the acute-FLW and control-FLW in longitudinal (5.09 +/- 0.9 MPa vs 1.72 +/- 0.56 MPa and 1.17 +/- 0.22 MPa) and circumferential (4.16 +/- 0.67 MPa vs 1.04 +/- 0.24 MPa and 1.07 +/- 0.16 MPa) directions. The lower tangent modulus of chronic-FLW is larger (P <.05) than acute-FLW and control-FLW in both directions (longitudinal: 0.72 +/- 0.24 MPa vs 0.13 +/- 0.02 MPa and 0.27 +/- 0.03 MPa circumferential:0.44 +/- 0.13 MPa vs 0.12 +/- 0.01 MPa and 0.21 +/- 0.02 MPa). The volume fraction of collagen was increased (P <.01) and the volume fraction of elastin was decreased (P <.001) when comparing chronic-FLW, acute-FLW, and controlFLW (collagen-volume fraction: 0.24 +/- 0.03 vs 0.12 +/- 0.03 and 0.08 +/- 0.02; elastinvolume fraction: 0.09 +/- 0.03 vs 0.28 +/- 0.03 and 0.39 +/- 0.04). Conclusions: As the acutely dissected aorta transitions to the chronic phase, the FL remodels by increasing collagen, decreasing elastin, and increasing aortic stiffness and thickness. This change in the chronic-FLW may be a protective adaptation to prevent FL enlargement and rupture in type B aortic dissection.
引用
收藏
页码:60 / 68
页数:9
相关论文
共 50 条
  • [1] Aortic Diameter, True Lumen, and False Lumen Growth Rates in Chronic Type B Aortic Dissection
    Blount, Kevin J.
    Hagspiel, Klaus D.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 192 (05) : W222 - W229
  • [2] Techniques and outcomes of false lumen embolization in chronic type B aortic dissection
    Rohlffs, Fiona
    Spanos, Konstantinos
    Tsilimparis, Nikolaos
    Debus, Eike S.
    Koelbel, Tilo
    JOURNAL OF CARDIOVASCULAR SURGERY, 2018, 59 (06): : 784 - 788
  • [3] The Knickerbocker Technique for Endovascular Exclusion of False Lumen in Chronic Type B Aortic Dissection
    Verzini, Fabio
    Loschi, Diletta
    Simonte, Gioele
    Farchioni, Luca
    Parlani, Gianbattista
    De Rango, Paola
    JOURNAL OF VASCULAR SURGERY, 2016, 63 (06) : 231S - 232S
  • [4] Placement of a branched stent graft into the false lumen of a chronic type B aortic dissection
    Simring, Dominic
    Raja, Jowad
    Morgan-Rowe, Luke
    Hague, Julian
    Harris, Peter L.
    Ivancev, Krassi
    JOURNAL OF VASCULAR SURGERY, 2011, 54 (06) : 1784 - 1787
  • [5] Aortic Arch False Lumen Embolisation in a Residual Chronic Type A Aortic Dissection
    Pellenc, Quentin
    Castier, Yves
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2019, 58 (04) : 600 - 601
  • [6] Volume changes in aortic true and false lumen after the "PETTICOAT" procedure for type B aortic dissection
    Melissano, Germano
    Bertoglio, Luca
    Rinaldi, Enrico
    Civilini, Efrem
    Tshomba, Yamume
    Kahlberg, Andrea
    Agricola, Eustachio
    Chiesa, Roberto
    JOURNAL OF VASCULAR SURGERY, 2012, 55 (03) : 641 - 651
  • [7] Intercostal Coil Embolization to Induce False Lumen Thrombosis in Chronic Type B Aortic Dissection
    Yi, Jeniann A.
    Magee, Gregory A.
    Eldeiry, Mohammed
    Reese, T. Brett
    Kuwayama, David P.
    JOURNAL OF VASCULAR SURGERY, 2019, 69 (06) : E207 - E207
  • [8] A Case Report of Type B Aortic Dissection With Ruptured False Lumen
    Suthar, Pokhraj P.
    Hussein, Mohamed Z.
    Gaddikeri, Ramya
    Shah, Palmi
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (07)
  • [9] Factors Affecting False Lumen Thrombosis In Type B Aortic Dissection
    Tang, Qian-hui
    Chen, Jing
    Yang, Han
    Qin, Zhong
    Lin, Qiu-ning
    Qin, Xiao
    ARQUIVOS BRASILEIROS DE CARDIOLOGIA, 2023, 120 (08)
  • [10] Coil Embolization of the False Lumen in Complicated Type B Aortic Dissection
    Hussain, Mohamad A.
    Lindsay, Thomas F.
    Tan, Kong T.
    Moloney, Tony
    ANNALS OF VASCULAR SURGERY, 2015, 29 (01)