Balloon-versus self-expandable transcatheter aortic valve implantation in small aortic annuli: a meta-analysis of randomized and propensity studies

被引:0
|
作者
Baudo, Massimo [1 ]
Sicouri, Serge [1 ]
Yamashita, Yoshiyuki [1 ,2 ]
Magouliotis, Dimitrios [1 ]
Cabrucci, Francesco [1 ]
Carnila, Sarah [1 ]
Ramlawi, Basel [1 ,2 ]
机构
[1] Lankenau Inst Med Res, Dept Cardiac Surg Res, Main Line Hlth, 100 E Lancaster Ave, Wynnewood, PA 19096 USA
[2] Lankenau Heart Inst, Dept Cardiac Surg, Main Line Hlth, Wynnewood, PA USA
关键词
Transcatheter aortic valve implantation; Small annulus; Balloon-expandable valve; Self-expandable valve; Meta-analysis; 5-YEAR OUTCOMES; REPLACEMENT; STENOSIS; MISMATCH;
D O I
10.1007/s12928-025-01105-w
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The hemodynamic and clinical differences between balloon- (BEV) and self-expandable valves (SEV) are critical for patients with a small aortic annulus (SAA). This meta-analysis aims to evaluate the clinical and hemodynamic performance of these two systems in patients with severe aortic stenosis and SAA. A systematic review was conducted from inception to June 2024 for randomized and propensity-score studies comparing BEV and SEV outcomes in patients with a SAA. Reconstructed individual patient data (IPD) from Kaplan Meier curves was pooled for overall survival and rehospitalization for heart failure. Nine studies with 2856 patients met our inclusion criteria: 1427 in the BEV group and 1429 in the SEV group. SEV demonstrated superior hemodynamic performance, including improved iEOA (Standardized Mead Difference [SMD]: 0.52, p = 0.0012), lower mean gradients (SMD: - 0.89, p < 0.0001), and reduced PPM (Odds Ratio [OR]: 0.38, p < 0.0001) compared to BEV. BEV presented lower new pacemaker rates compared to SEV (OR: 1.52, p = 0.0447). There were no significant differences between SEV and BEV in terms of rates of > mild paravalvular leaks, early stroke, and Valve Academic Research Consortium-defined outcomes. Reconstructed IPD showed no significant differences in overall survival (Hazard Ratio [HR]: 0.95, p = 0.584) and rehospitalization for heart failure (HR: 1.05, p = 0.828) during follow-up. In patients with SAA undergoing TAVI the use of BEV was associated with higher frequency of PPM and/or pressure gradients. Similar early stroke, survival and rehospitalization rates were reported. Pacemaker rates were higher with SEV. Long-term follow-up studies are required, especially with newer-generation devices. [GRAPHICS] .
引用
收藏
页数:12
相关论文
共 50 条
  • [41] Meta-analysis Comparing Valve-In-Valve Transcatheter Aortic Valve Implantation With Self-Expanding Versus Balloon-Expandable Valves
    Hamilton, Garry W.
    Koshy, Anoop N.
    Fulcher, Jordan
    Tang, Gilbert H. L.
    Bapat, Vinayak
    Murphy, Alexandra
    Horrigan, Mark
    Farouque, Omar
    Yudi, Matias B.
    AMERICAN JOURNAL OF CARDIOLOGY, 2020, 125 (10): : 1558 - 1565
  • [42] Outcomes of Self-Expanding vs Balloon-Expandable Transcatheter Aortic Valves in Patients With Small Aortic Annuli: A Meta-analysis
    Elseidy, Sheref
    Vorla, Mounica
    Hamed, Mohamed
    Rehan, Manahil
    Isaac, John
    Mohamad, Tamam
    Castiello, Teresa
    Mamas, Mamas
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2024, 84 (18) : B393 - B393
  • [43] Balloon Expandable Versus Self Expanding Transcatheter Aortic Valve Systems: A Bayesian Network Meta-Analysis
    Osman, Mohammed
    Ghaffar, Yasir Abdul
    Saleem, Maryam
    Kheiri, Babikir
    Osman, Khansa
    Munir, Muhamad
    Alkhouli, Mohamad
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2019, 74 (13) : B723 - B723
  • [44] Meta-analysis Comparing Outcomes of Self-Expanding Versus Balloon-Expandable Valves for Transcatheter Aortic Valve Implantation
    Elgendy, Islam Y.
    Gad, Mohamed M.
    Mahmoud, Ahmed N.
    Dvir, Danny
    Kapadia, Samir R.
    Alfonso, Fernando
    Capodanno, Davide
    AMERICAN JOURNAL OF CARDIOLOGY, 2020, 128 : 202 - 209
  • [45] Pacemaker implantation after balloon- or self-expandable transcatheter aortic valve replacement in patients with aortic stenosis
    Bodin, A.
    Bisson, A.
    Herbert, J.
    Lacour, T.
    Saint Etienne, C.
    Pierre, B.
    Deharo, P.
    Babuty, D.
    Clementy, N.
    Fauchier, L.
    EUROPEAN HEART JOURNAL, 2020, 41 : 714 - 714
  • [46] Transcatheter Aortic Valve Implantation of a Self-expandable Valve for Pure Aortic Regurgitation Without Aortic Valve Calcification
    Yin, Wei-Hsien
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 71 (16) : S63 - S64
  • [47] Pacemaker Implantation After Balloon- or Self-Expandable Transcatheter Aortic Valve Replacement in Patients With Aortic Stenosis
    Bisson, Arnaud
    Bodin, Alexandre
    Herbert, Julien
    Lacour, Thibaut
    Saint Etienne, Christophe
    Pierre, Bertrand
    Clementy, Nicolas
    Deharo, Pierre
    Babuty, Dominique
    Fauchier, Laurent
    JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2020, 9 (09):
  • [48] Aortic annulus eccentricity before and after transcatheter aortic valve implantation: comparison of balloon-expandable and self-expandable prostheses
    Schuhbaeck, A.
    Weingartner, C.
    Arnold, M.
    Schmid, J.
    Pflederer, T.
    Marwan, M.
    Nef, H.
    Uder, M.
    Weyand, M.
    Achenbach, S.
    EUROPEAN HEART JOURNAL, 2013, 34 : 31 - 32
  • [49] Comparison of outcomes of self-expanding versus balloon-expandable valves for transcatheter aortic valve replacement: a meta-analysis of randomized and propensity-matched studies
    Wang, Baiqiang
    Mei, Zeyuan
    Ge, Xiao
    Li, Yunyi
    Zhou, Quan
    Meng, Xiao
    An, Guipeng
    BMC CARDIOVASCULAR DISORDERS, 2023, 23 (01)
  • [50] Comparison of outcomes of self-expanding versus balloon-expandable valves for transcatheter aortic valve replacement: a meta-analysis of randomized and propensity-matched studies
    Baiqiang Wang
    Zeyuan Mei
    Xiao Ge
    Yunyi Li
    Quan Zhou
    Xiao Meng
    Guipeng An
    BMC Cardiovascular Disorders, 23