Myocardium; Training; Optimization; Vectors; Robustness; Signal to noise ratio; Convolutional neural networks; Accuracy; Visualization; Stress; Deep learning; fermi-deconvolution; magnetic resonance imaging; myocardial perfusion quantification; CARDIOVASCULAR MAGNETIC-RESONANCE; EMISSION COMPUTED-TOMOGRAPHY; CORONARY-ARTERY-DISEASE; STATEMENT; IMPACT; NOISE; HEART;
D O I
10.1109/TBME.2024.3485233
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Stress perfusion cardiac magnetic resonance is an important technique for examining and assessing the blood supply of the myocardium. Currently, the majority of clinical perfusion scans are evaluated based on visual assessment by experienced clinicians. This makes the process subjective, and to this end, quantitative methods have been proposed to offer a more user-independent assessment of perfusion. These methods, however, rely on time-consuming deconvolution analysis and are susceptible to data outliers caused by artifacts due to cardiac or respiratory motion. In our work, we introduce a novel deep-learning method that integrates the commonly used Fermi function with a neural network architecture for fast, accurate, and robust myocardial perfusion quantification. This approach employs the Fermi model to ensure that the perfusion maps are consistent with measured data, while also utilizing a prior based on a 3D convolutional neural network to generalize spatio-temporal information across different patient data. Our network is trained within a self-supervised learning framework, which circumvents the need for ground-truth perfusion labels that are challenging to obtain. Furthermore, we extended this training methodology by adopting a technique that ensures estimations are resistant to data outliers, thereby improving robustness against motion artifacts. Our simulation experiments demonstrated an overall improvement in the accuracy and robustness of perfusion parameter estimation, consistently outperforming traditional deconvolution analysis algorithms across varying Signal-to-Noise Ratio scenarios in the presence of data outliers. For the in vivo studies, our method generated robust perfusion estimates that aligned with clinical diagnoses, while being approximately five times faster than conventional algorithms.
引用
收藏
页码:1031 / 1044
页数:14
相关论文
共 50 条
  • [31] Quantification of porcine myocardial perfusion with modified dual bolus MRI – a prospective study with a PET reference
    Minna Husso
    Mikko J. Nissi
    Antti Kuivanen
    Paavo Halonen
    Miikka Tarkia
    Jarmo Teuho
    Virva Saunavaara
    Pauli Vainio
    Petri Sipola
    Hannu Manninen
    Seppo Ylä-Herttuala
    Juhani Knuuti
    Juha Töyräs
    BMC Medical Imaging, 19
  • [32] 237 MRI myocardial perfusion quantification: effects from contrast dose, imaging plane and sequence
    Yi Wang
    Raphael Hazel
    Bin Luo
    Margerite Roth
    Jing Han
    William Schapiro
    Jie J Cao
    Nathaniel Reichek
    Journal of Cardiovascular Magnetic Resonance, 10 (Suppl 1)
  • [33] Safety and Efficacy of Regadenoson for Pediatric Stress Perfusion Cardiac MRI with Quantification of Myocardial Blood Flow
    Patel, Shivani G.
    Husain, Nazia
    Rigsby, Cynthia K.
    Robinson, Joshua D.
    CHILDREN-BASEL, 2022, 9 (09):
  • [34] An Empirical Method for Reducing Variability and Complexity of Myocardial Perfusion Quantification by Dual Bolus Cardiac MRI
    Chatterjee, Neil
    Benefield, Brandon C.
    Harris, Kathleen R.
    Fluckiger, Jacob U.
    Carroll, Timothy
    Lee, Daniel C.
    MAGNETIC RESONANCE IN MEDICINE, 2017, 77 (06) : 2347 - 2355
  • [35] Very early cardiac MRI for quantification of myocardial tissue perfusion in patients receiving tirofiban for ST elevation myocardial infariction
    Lehrke, S
    Steen, H
    Kuhlke, C
    Mertens, C
    Schuster, L
    Gehl, HB
    Giannitsis, E
    CIRCULATION, 2003, 108 (17) : 453 - 453
  • [36] A MRI myocardial perfusion analysis tool
    Nee, G.
    Jehan-Besson, S.
    Brun, L.
    Revenu, M.
    Hamon, M.
    Hamon-Kerautret, M.
    Perrin, M.
    2009 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-20, 2009, : 4387 - +
  • [37] Quantitative Assessment of Myocardial Perfusion MRI
    Ishida M.
    Morton G.
    Schuster A.
    Nagel E.
    Chiribiri A.
    Current Cardiovascular Imaging Reports, 2010, 3 (2) : 65 - 73
  • [38] Status of myocardial perfusion assessment by MRI
    Fischer, SE
    Lorenz, CH
    WHAT'S NEW IN CARDIOVASCULAR IMAGING?, 1998, 204 : 247 - 260
  • [39] Image registration in myocardial perfusion MRI
    Wong, K. K.
    Wu, E. X.
    Ng, M. C.
    Wu, Y.
    Tse, H. F.
    Lau, C. P.
    Yang, E. S.
    2005 27TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2005, : 453 - 454
  • [40] Myocardial perfusion modeling using MRI
    Larsson, HBW
    FritzHansen, T
    Rostrup, E
    Sondergaard, L
    Ring, P
    Henriksen, O
    MAGNETIC RESONANCE IN MEDICINE, 1996, 35 (05) : 716 - 726