Measurement Uncertainty and Validation for Quantification of Marijuana Metabolite: (-)-11-nor-9-Carboxy-Δ9-THC in Human Urine by GC-MS/MS

被引:0
|
作者
Maurya, Ashok Kumar [1 ]
Sahu, Puran Lal [1 ]
Sahu, Kapendra [1 ]
机构
[1] Govt India, Minist Youth Affairs & Sports MYAS, Natl Dope Testing Lab, New Delhi 110003, India
关键词
Cannabinoids; (-)-11-nor-9-Carboxy-Delta 9-THC; validation; ICH guidelines; GC-MS/MS; doping control; human urine; WADA; LC-MS/MS; THC-COOH; CONFIRMATION; SAMPLES;
D O I
10.2174/0115734129347983241023100539
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Background Since the International Olympic Committee (IOC) was established, sports doping control analyses have revealed a high rate of positive cases for cannabinoids. Cannabinoids were banned in all sports where they were used in competition as per the Prohibited List published annually. Further, it was also included in the threshold drug category. Consequently, developing a reliable method for urine Cannabinoids metabolite quantification plays a pivotal role in sports dope testing.Objective This work aimed to develop and validate a reliable, cost-effective, robust gas chromatography-tandem mass spectrometry method for detecting (-)-11-nor-9-Carboxy-Delta 9-THC component in human urine samples, in compliance with ICH and WADA guidelines.Method The sample preparation was done by enzymatic hydrolysis for deconjugation, further proceeded with solid phase extraction (SPE), liquid-liquid extraction (LLE), and using an XAD2 column, and N-methyl trimethylsilyl trifluoroacetamide (MSTFA) for derivatization.Results The linearity was obtained in a range of 50-300 ng/mL, and the correlation coefficient was found to be higher than 0.99. Throughout the entire validation study, the difference in Retention Time (RT) for the analyte, including the Internal Standard (IS), was shown to be less than 1.0%. The quantification limit (LOQ) was calculated at a level of 50 ng/mL in human urine samples for the 3 most abundant ion transitions. The detection limit (LOD) was established at 4 ng/mL.Conclusion The accuracy, precision, linearity, recovery, quantification limit, and selectivity by GC-MS/MS technique were found acceptable and well satisfactory while following the ICH guidelines. The developed method has been proven to be fit for purpose in accordance with the enforced Guidelines of WADA.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] 11-Nor-9-carboxy-∆9-tetrahydrocannabinol quantification in human oral fluid by liquid chromatography–tandem mass spectrometry
    Karl B. Scheidweiler
    Sarah K. Himes
    Xiaohong Chen
    Hua-Fen Liu
    Marilyn A. Huestis
    Analytical and Bioanalytical Chemistry, 2013, 405 : 6019 - 6027
  • [32] Conversion of 7-Carboxy-Cannabidiol (7-COOH-CBD) to 11-Nor-9-Carboxy-Tetrahydrocannabinol (THC-COOH) during Sample Preparation for GC-MS Analysis
    Hart, E. Dale
    Vikingsson, Svante
    Mitchell, John M.
    Winecker, Ruth E.
    Flegel, Ronald
    Hayes, Eugene D.
    JOURNAL OF ANALYTICAL TOXICOLOGY, 2021, 46 (05) : 573 - 576
  • [33] Determination of amphetamines, opioids, cocaine metabolites and 11-nor-9-carboxy-Δ9-tetrahydrocannabinol in urine using biocompatible solid-phase microextraction and ultra-performance LC-MS/MS
    Schneider, Anelise
    Feltraco Lizot, Lilian de Lima
    Reginatto, Gessica Carpes
    Hahn, Roberta Zilles
    Bastiani, Marcos F.
    Bondan, Amanda Pacheco
    Perassolo, Magda S.
    Linden, Rafael
    BIOANALYSIS, 2023, 15 (15) : 905 - 914
  • [34] A GC-MS METHOD FOR DETERMINATION OF DELTA-9-TETRAHYDROCANNABINOL-11-OIC ACID IN HUMAN URINE
    YAMAMOTO, I
    WATANABE, K
    NARIMATSU, S
    MATSUNAGA, T
    KIJIMA, T
    HIRAIWA, K
    YOSHIMURA, H
    EISEI KAGAKU-JAPANESE JOURNAL OF TOXICOLOGY AND ENVIRONMENTAL HEALTH, 1990, 36 (02): : 149 - 152
  • [35] Synthesis of [13C4]-labeled Δ9-Tetrahydrocannabinol and 11-nor-9-Carboxy-Δ9-tetrahydrocannabinol as Internal Standards for Reducing Ion Suppressing/Alteration Effects in LC/MS-MS Quantification
    Karlsen, Morten
    Liu, Huiling
    Johansen, Jon Eigill
    Hoff, Bard Helge
    MOLECULES, 2014, 19 (09) : 13526 - 13540
  • [36] 11-Nor-9-carboxy-Δ9-tetrahydrocannabinol quantification in human oral fluid by liquid chromatography-tandem mass spectrometry
    Scheidweiler, Karl B.
    Himes, Sarah K.
    Chen, Xiaohong
    Liu, Hua-Fen
    Huestis, Marilyn A.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2013, 405 (18) : 6019 - 6027
  • [37] 11-Nor-9-Carboxy-Δ9-Tetrahydrocannabinol Quantification in Human Oral Fluid by Liquid Chromatography-Tandem Mass Spectrometry
    Scheidweiler, K. B.
    Himes, S. K.
    Chen, X.
    Liu, H. F.
    Huestis, M. A.
    THERAPEUTIC DRUG MONITORING, 2013, 35 (05) : 687 - 687
  • [38] Rapid and robust confirmation and quantification of 11-nor-?9-tetrahydrocannabinol-9-carboxylic acid (THC-COOH) in urine by column switching LC-MS-MS analysis
    Zanchetti, Gabriele
    Floris, Ivan
    Piccinotti, Alberto
    Tameni, Silvia
    Polettini, Aldo
    JOURNAL OF MASS SPECTROMETRY, 2012, 47 (01): : 124 - 130
  • [39] GC-MS analysis of the total Δ9-THC content of both drug- and fiber-type cannabis seeds
    Ross, SA
    Mehmedic, Z
    Murphy, TP
    ElSohly, MA
    JOURNAL OF ANALYTICAL TOXICOLOGY, 2000, 24 (08) : 715 - 717
  • [40] Simultaneous determination of 11-nor-Δ9-carboxy-tetrahydrocannabinol and 11-nor- increment 9-carboxy-tetrahydrocannabinol-glucuronide in urine samples by LC-MS/MS and its application to forensic science
    Park, Meejung
    Kim, Sineun
    ANALYTICAL SCIENCE AND TECHNOLOGY, 2021, 34 (06): : 259 - 266