Laboratory-based molecular test alternatives to RT-PCR for the diagnosis of SARS-CoV-2 infection

被引:1
|
作者
Arevalo-Rodriguez, Ingrid [1 ,2 ]
Mateos-Haro, Miriam [3 ,4 ]
Dinnes, Jacqueline [5 ,6 ,7 ]
Ciapponi, Agustin [8 ]
Davenport, Clare [5 ,6 ,7 ]
Buitrago-Garcia, Diana [9 ,10 ]
Bennouna-Dalero, Tayeb [11 ]
Roque-Figuls, Marta [12 ]
Van den Bruel, Ann [13 ]
von Eije, Karin J. [14 ]
Emperador, Devy [15 ]
Hooft, Lotty [16 ]
Spijker, Rene [16 ]
Leeflang, Mariska M. G. [17 ]
Takwoingi, Yemisi [5 ,6 ,7 ]
Deeks, Jonathan J. [5 ,6 ,7 ]
机构
[1] Hosp Univ Ramon y Cajal IRYCIS, Clin Biostat Unit, CIBER Epidemiol & Publ Hlth CIBERESP, Madrid, Spain
[2] Evidence Prod & Methods Directorate, London, England
[3] Hosp Univ Ramon y Cajal IRYCIS, Clin Biostat Unit, Madrid, Spain
[4] Univ Granada, Doctoral Programme Clin Med & Publ Hlth, Granada, Spain
[5] Univ Birmingham, Sch Hlth Sci, Dept Appl Hlth Sci, Coll Med & Hlth, Birmingham, W Midlands, England
[6] Univ Hosp Birmingham NHS Fdn Trust, NIHR Birmingham Biomed Res Ctr, Birmingham, W Midlands, England
[7] Univ Birmingham, Birmingham, W Midlands, England
[8] Inst Clin Efectiveness & Hlth Policy IECS CONICET, Argentine Cochrane Ctr, Buenos Aires, DF, Argentina
[9] Univ Bern, Inst Social & Prevent Med, Bern, Switzerland
[10] Univ Rosario, Hosp Univ Mayor Mederi, Bogota, Colombia
[11] Hosp Univ Ramon y Cajal IRYCIS, Prevent Med & Publ Hlth Dept, Madrid, Spain
[12] CIBER Epidemiol & Salud Publ CIBERESP, Inst Recerca St Pau IR SANT PAU, Iberoamer Cochrane Ctr, Barcelona, Spain
[13] Katholieke Univ Leuven, Acad Ctr Gen Practice, Leuven, Belgium
[14] Univ Med Ctr, Dept Virosci, ErasmusMC, Rotterdam, Netherlands
[15] FIND, Geneva, Switzerland
[16] Univ Utrecht, Univ Med Ctr Utrecht, Julius Ctr Hlth Sci & Primary Care, Cochrane Netherlands, Utrecht, Netherlands
[17] Univ Amsterdam, Amsterdam Univ Med Ctr, Dept Clin Epidemiol Biostat & Bioinformat, Amsterdam, Netherlands
关键词
ACUTE RESPIRATORY SYNDROME; DROPLET DIGITAL PCR; POLYMERASE-CHAIN-REACTION; REAL-TIME PCR; RAPID DETECTION; ISOTHERMAL AMPLIFICATION; CLINICAL-EVALUATION; ENZYMATIC AMPLIFICATION; COVID-19; DETECTION; IN-VITRO;
D O I
10.1002/14651858.CD015618
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Diagnosing people with a SARS-CoV-2 infection played a critical role in managing the COVID-19 pandemic and remains a priority for the transition to long-term management of COVID-19. Initial shortages of extraction and reverse transcription polymerase chain reaction (RTPCR) reagents impaired the desired upscaling of testing in many countries, which led to the search for alternatives to RNA extraction/purification and RT-PCR testing. Reference standard methods for diagnosing the presence of SARS-CoV-2 infection rely primarily on real-time reverse transcription-polymerase chain reaction (RT-PCR). Alternatives to RT-PCR could, if sufficiently accurate, have a positive impact by expanding the range of diagnostic tools available for the timely identification of people infected by SARS-CoV-2, access to testing and the use of resources. Objectives To assess the diagnostic accuracy of alternative (to RT-PCR assays) laboratory-based molecular tests for diagnosing SARS-CoV-2 infection. Search methods We searched the COVID-19 Open Access Project living evidence database from the University of Bern until 30 September 2020 and the WHO COVID-19 Research Database until 31 October 2022. We did not apply language restrictions. Selection criteria We included studies of people with suspected or known SARS-CoV-2 infection, or where tests were used to screen for infection, and studies evaluating commercially developed laboratory-based molecular tests for the diagnosis of SARS-CoV-2 infection considered as alternatives to RT-PCR testing. We also included all reference standards to define the presence or absence of SARS-CoV-2, including RT-PCR tests and established clinical diagnostic criteria. Data collection and analysis Two authors independently screened studies and resolved disagreements by discussing them with a third author. Two authors independently extracted data and assessed the risk of bias and applicability of the studies using the QUADAS-2 tool. We presented sensitivity and specificity, with 95% confidence intervals (CIs), for each test using paired forest plots and summarised results using average sensitivity and specificity using a bivariate random-effects meta-analysis. We illustrated the findings per index test category and assay brand compared to the WHO's acceptable sensitivity and specificity threshold for diagnosing SARS-CoV-2 infection using nucleic acid tests. Main results We included data from 64 studies reporting 94 cohorts of participants and 105 index test evaluations, with 74,753 samples and 7517 confirmed SARS-CoV-2 cases. We did not identify any published or preprint reports of accuracy for a considerable number of commercially produced NAAT assays. Most cohorts were judged at unclear or high risk of bias in more than three QUADAS-2 domains. Around half of the cohorts were considered at high risk of selection bias because of recruitment based on COVID status. Three quarters of 94 cohorts were at high risk of bias in the reference standard domain because of reliance on a single RT-PCR result to determine the absence of SARS-CoV-2 infection or were at unclear risk of bias due to a lack of clarity about the time interval between the index test assessment and the reference standard, the number of missing results, or the absence of a participant flow diagram. For index tests categories with four or more evaluations and when summary estimations were possible, we found that: a) For RT-PCR assays designed to omit/adapt RNA extraction/purification, the average sensitivity was 95.1% (95% CI 91.1% to 97.3%), and the average specificity was 99.7% (95% CI 98.5% to 99.9%; based on 27 evaluations, 2834 samples and 1178 SARS-CoV-2 cases); b) For RT-LAMP assays, the average sensitivity was 88.4% (95% CI 83.1% to 92.2%), and the average specificity was 99.7% (95% CI 98.7% to 99.9%; 24 evaluations, 29,496 samples and 2255 SARS-CoV-2 cases); c) for TMA assays, the average sensitivity was 97.6% (95% CI 95.2% to 98.8%), and the average specificity was 99.4% (95% CI 94.9% to 99.9%; 14 evaluations, 2196 samples and 942 SARS-CoV-2 cases); d) for digital PCR assays, the average sensitivity was 98.5% (95% CI 95.2% to 99.5%), and the average specificity was 91.4% (95% CI 60.4% to 98.7%; five evaluations, 703 samples and 354 SARS-CoV-2 cases); e) for RT-LAMP assays omitting/adapting RNA extraction, the average sensitivity was 73.1% (95% CI 58.4% to 84%), and the average specificity was 100% (95% CI 98% to 100%; 24 evaluations, 14,342 samples and 1502 SARS-CoV-2 cases). Only two index test categories fulfil the WHO-acceptable sensitivity and specificity requirements for SARS-CoV-2 nucleic acid tests: RT-PCR assays designed to omit/adapt RNA extraction/purification and TMA assays. In addition, WHO-acceptable performance criteria were met for two assays out of 35 when tests were used according to manufacturer instructions. At 5% prevalence using a cohort of 1000 people suspected of SARS-CoV-2 infection, the positive predictive value of RT-PCR assays omitting/adapting RNA extraction/purification will be 94%, with three in 51 positive results being false positives, and around two missed cases. For TMA assays, the positive predictive value of RT-PCR assays will be 89%, with 6 in 55 positive results being false positives, and around one missed case. Authors' conclusions Alternative laboratory-based molecular tests aim to enhance testing capacity in different ways, such as reducing the time, steps and resources needed to obtain valid results. Several index test technologies with these potential advantages have not been evaluated or have been assessed by only a few studies of limited methodological quality, so the performance of these kits was undetermined. Only two index test categories with enough evaluations for meta-analysis fulfil the WHO set of acceptable accuracy standards for SARS-CoV-2 nucleic acid tests: RT-PCR assays designed to omit/adapt RNA extraction/purification and TMA assays. These assays might prove to be suitable alternatives to RT-PCR for identifying people infected by SARS-CoV-2, especially when the alternative would be not having access to testing. However, these findings need to be interpreted and used with caution because of several limitations in the evidence, including reliance on retrospective samples without information about the symptom status of participants and the timing of assessment. No extrapolation of found accuracy data for these two alternatives to any test brands using the same techniques can be made as, for both groups, one test brand with high accuracy was overrepresented with 21/26 and 12/14 included studies, respectively. Although we used a comprehensive search and had broad eligibility criteria to include a wide range of tests that could be alternatives to RT-PCR methods, further research is needed to assess the performance of alternative COVID-19 tests and their role in pandemic management.
引用
收藏
页数:427
相关论文
共 50 条
  • [41] SARS-CoV-2 RT-PCR: at least 2 viral targets are needed
    Farfour, Eric
    Jolly, Emilie
    Pascreau, Tiffany
    Asso-Bonnet, Marianne
    Mazaux, Laurence
    Vasse, Marc
    INFECTIOUS DISEASES, 2020, 52 (08) : 583 - 584
  • [42] Diagnosis of infection by SARS-COV-2: Is one molecular test enough?
    Mencacci, Antonella
    Vedovati, Maria Cristina
    Camilloni, Barbara
    Cenci, Elio
    Becattini, Cecilia
    EUROPEAN JOURNAL OF INTERNAL MEDICINE, 2021, 87 : 109 - 111
  • [43] Comparison of SARS-CoV-2 antigen electrochemiluminescence immunoassay to RT-PCR assay for laboratory diagnosis of COVID-19 in Peshawar
    Iqbal, Bilal
    Khan, Maria
    Shah, Noman
    Dawood, Mirza Muhammad
    Jehanzeb, Valeed
    Shafi, Mohsin
    DIAGNOSIS, 2022, 9 (03) : 364 - 368
  • [44] Validation of a Saliva-Based Test for the Molecular Diagnosis of SARS-CoV-2 Infection
    Bulfoni, Michela
    Sozio, Emanuela
    Marcon, Barbara
    De Martino, Maria
    Cesselli, Daniela
    De Carlo, Chiara
    Martinella, Romina
    Migotti, Angelica
    Vania, Eleonora
    Zanus-Fortes, Agnese
    De Piero, Jessica
    Nencioni, Emanuele
    Tascini, Carlo
    Isola, Miriam
    Curcio, Francesco
    DISEASE MARKERS, 2022, 2022
  • [45] Performance of Chip Based Real Time RT-PCR (Truenat) and Conventional Real Time RT-PCR for Detection of SARS-CoV-2
    Sahoo, Amiyabala
    Shulania, Anuradha
    Chhabra, Mala
    Kansra, Stuti
    Achra, Arvind
    Nirmal, Kirti
    Katiyar, Supriya
    Duggal, Nandini
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2021, 15 (11) : DC25 - DC28
  • [46] Evaluation of SARS-CoV-2 Positivity by RT-PCR in a Clinical Laboratory in Sao Paulo during 2022
    Silva, E. M.
    Tada, M. T.
    Melo, N. C.
    Silva, J. S. L.
    Nociti, D. A.
    Pereira, C. R. M.
    Cavalcanti, C. F. A.
    Coudry, R. A.
    JOURNAL OF MOLECULAR DIAGNOSTICS, 2023, 25 (06): : S40 - S40
  • [47] Comparison of FTD SARS-CoV-2 Assay and RealStar RT-PCR kit 1.0 for the detection of SARS-CoV-2
    Di Carlo, Daniele
    Mazzuti, Laura
    Sciandra, Ilaria
    Guerrizio, Giuliana
    Oliveto, Giuseppe
    Cabral, Rodolfo J. Riveros
    Zingaropoli, Maria Antonella
    Turriziani, Ombretta
    JOURNAL OF VIROLOGICAL METHODS, 2021, 298
  • [48] Evaluation of self-collected nasal, urine, and saliva samples for molecular detection of SARS-CoV-2 using an EUA approved RT-PCR assay and a laboratory developed LAMP SARS-CoV-2 test
    Purcell-Wiltz, Ana
    Zamuner, Fernando Tadeu
    Caraballo, Karem
    De Jesus, Lorena
    Miranda, Yaima
    Ortiz, Denise
    Negron, Amanda Garcia
    Ortiz, Andrea Cortes
    Baez, Adriana
    Romaguera, Josefina
    Jimenez, Ivonne
    Ortiz, Alberto
    Acevedo, Jorge
    Viera, Liliana
    Sidransky, David
    Guerrero-Preston, Rafael
    IMMUNITY INFLAMMATION AND DISEASE, 2024, 12 (06)
  • [49] Comparison of SARS-CoV-2 detection from nasopharyngeal swab samples by the Roche cobas 6800 SARS-CoV-2 test and a laboratory-developed real-time RT-PCR test
    Pujadas, Elisabet
    Ibeh, Nnaemeka
    Hernandez, Matthew M.
    Waluszko, Aneta
    Sidorenko, Tatyana
    Flores, Vanessa
    Shiffrin, Biana
    Chiu, Numthip
    Young-Francois, Alicia
    Nowak, Michael D.
    Paniz-Mondolfi, Alberto E.
    Sordillo, Emilia M.
    Cordon-Cordo, Carlos
    Houldsworth, Jane
    Gitman, Melissa R.
    JOURNAL OF MEDICAL VIROLOGY, 2020, 92 (09) : 1695 - 1698
  • [50] Detection of SARS-CoV-2 using a laboratory-developed ultra-fast NextGenPCR test versus a conventional RT-PCR test
    Curova, Katarina
    Lovayova, Viera
    Nagyova, Maria
    Siegfried, Leonard
    Donic, Viliam
    de Vos, Gert
    ACTA VIROLOGICA, 2023, 67