Haemodynamic measurements during hip hemiarthroplasty surgery for hip fracture AN OBSERVATIONAL STUDY

被引:0
|
作者
Fernandez, M. A. [1 ]
Henshaw, F. [1 ]
Carlos, W. J. [1 ]
Kelly, A. [1 ]
Griffin, X. L. [1 ]
Costa, M. L. [1 ]
机构
[1] Univ Hosp Coventry & Warwickshire NHS Trust, Coventry, England
来源
BONE & JOINT JOURNAL | 2025年 / 107B卷 / 01期
基金
美国国家卫生研究院;
关键词
UNCEMENTED HEMIARTHROPLASTY; CEMENTED HEMIARTHROPLASTY; ARTERIAL-PRESSURE; PERIOPERATIVE MORTALITY; CARDIAC-OUTPUT; RISK-FACTORS; ECHOCARDIOGRAPHY; ANESTHESIA; CNAP(TM); MONITOR;
D O I
10.1302/0301-620X.107B1.BJJ-2024-0548.R1
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Aims There is compelling evidence for the use of cemented hip hemiarthroplasty for displaced intracapsular hip fractures; however, the risks of cement are well reported and in rare cases may be associated with haemodynamic collapse. It is therefore important to improve our understanding of haemodynamic instability, intraoperative monitoring, and strategies to reduce the risk to patients. Methods We measured arterial blood pressure using the LiDCOrapid Continuous Non- invasive Arterial Pressure (CNAP) finger cuff during surgery in patients enrolled in the WHiTE 5 trial randomized to cemented or modern uncemented hip hemiarthroplasty at a single recruiting site. We observed the incidence, timing, and magnitude of haemodynamic instability at key stages of the surgical procedure. Results We obtained measurements from 56 patients, of whom 46 had complete recordings and were used in the analysis. Modest falls in systolic blood pressure (20% to 30%) occurred in four patients (15%) who received a cemented hemiarthroplasty and one patient (5%) in the uncemented group. The fall in blood pressure occurred either within five minutes of cementing or at final hip reduction. We observed concurrent drops in cardiac output (CO) and stroke volume (SV). Conclusion We observed the presence of two potential periods for haemodynamic instability during hip hemiarthroplasty surgery: the first was within five minutes of cementing the femoral canal and the second after final reduction of the prosthesis (observed in both cemented and uncemented hemiarthroplasty). The falls in blood pressure appeared to be driven by reduced CO and SV.
引用
收藏
页码:103 / 107
页数:5
相关论文
共 50 条
  • [31] Hip fracture predicts subsequent hip fracture: a retrospective observational study to support a call to early hip fracture prevention efforts in post-fracture patients
    Schemitsch, Emil
    Adachi, Jonathan D.
    Brown, Jacques P.
    Tarride, Jean-Eric
    Burke, Natasha
    Oliveira, Thiago
    Slatkovska, Lubomira
    OSTEOPOROSIS INTERNATIONAL, 2022, 33 (01) : 113 - 122
  • [32] Hip fracture predicts subsequent hip fracture: a retrospective observational study to support a call to early hip fracture prevention efforts in post-fracture patients
    Emil Schemitsch
    Jonathan D. Adachi
    Jacques P. Brown
    Jean-Eric Tarride
    Natasha Burke
    Thiago Oliveira
    Lubomira Slatkovska
    Osteoporosis International, 2022, 33 : 113 - 122
  • [33] Prospective study assessing quality-of-life after hemiarthroplasty for hip fracture
    Poulain, S
    Bauer, T
    Bégué, T
    Hardy, P
    REVUE DE CHIRURGIE ORTHOPEDIQUE ET REPARATRICE DE L APPAREIL MOTEUR, 2005, 91 (05): : 423 - 431
  • [34] Hypotension during hip fracture surgery and postoperative morbidity
    Beecham, Gabriel
    Cusack, Rachael
    Vencken, Sebastian
    Crilly, Grace
    Buggy, Donal J.
    IRISH JOURNAL OF MEDICAL SCIENCE, 2020, 189 (03) : 1087 - 1096
  • [35] Hypotension during hip fracture surgery and postoperative morbidity
    Gabriel Beecham
    Rachael Cusack
    Sebastian Vencken
    Grace Crilly
    Donal J. Buggy
    Irish Journal of Medical Science (1971 -), 2020, 189 : 1087 - 1096
  • [36] Fluid-responsiveness, blood volume and perfusion in preoperative haemodynamic optimisation of hip fracture patients; a prospective observational study
    Agerskov, Marianne
    Sorensen, Henrik
    Hojlund, Jakob
    Secher, Niels H.
    Foss, Nicolai Bang
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2022, 66 (06) : 660 - 673
  • [37] Shamrock Lumbar Plexus Block for Hip Hemiarthroplasty in a High Risk Elderly Patient with Hip Fracture
    Soulioti, Eleftheria
    Kavezou, Foteini
    Giannoulis, Dimitrios
    Sidiropoulou, Tatiana
    Altsitzioglou, Pavlos
    Bekos, Achilles
    Mavrogenis, Andreas F.
    Journal of Long-Term Effects of Medical Implants, 2022, 32 (01): : 73 - 76
  • [38] Effects of total hip arthroplasty and hemiarthroplasty on hip function in patients with traumatic femoral neck fracture
    Li, Xiangwei
    Zhao, Lin
    Chen, Rong
    Cao, Hong
    Wei, Yuxi
    Wu, Xue
    Zhu, Guijuan
    Jiang, Liangbo
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2023, 143 (02) : 873 - 878
  • [39] How necessary are hip restrictions for avoiding dislocation following hemiarthroplasty or total hip arthroplasty in older patients with a hip fracture?
    Stewart, Lisa S. P.
    McMillan, Ian R.
    BRITISH JOURNAL OF OCCUPATIONAL THERAPY, 2011, 74 (03) : 110 - 118
  • [40] Role of Tranexamic Acid in Controlling Blood Loss in Hemiarthroplasty of the Hip: A Prospective and Observational Study
    Ahamed, Hamdi Nizar
    Mohan, Sandeep
    Krishnan, Rahul
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (06)