Reasons for Explantations of Posterior Chamber Phakic Intraocular Lenses in 1,490 Eyes

被引:0
|
作者
Coskunseven, Efekan [1 ,2 ]
Kayhan, Belma [3 ]
机构
[1] Zincirlikuyu Med Hosp, Refract Surg Dept, Istanbul, Turkiye
[2] Istanbul Yeni Yuzyil Univ, Fac Hlth Sci, Istanbul, Turkiye
[3] Univ Hlth Sci, Sultan II Abdulhamid Han Training & Res Hosp, Ophthalmol Dept, Istanbul, Turkiye
关键词
IMPLANTABLE COLLAMER LENS; OPTIMIZATION; MYOPIA;
D O I
10.3928/1081597X-20240913-03
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To investigate the reasons for the removal and/ or exchange of posterior chamber phakic intraocular lenses (PCPIOLs) and the outcomes of these procedures. METHODS: In this retrospective study, PCPIOL implantations performed between January 2015 and June 2023 in a single center were reviewed. The study group consisted of the files of eyes with removed and/or exchanged PCPIOL. Visual acuities, refraction errors, endothelial cell counts, and measurements of the vault before and after exchanges were recorded. Reasons for removal and/or exchange were evaluated. The tuck-and-pull technique was used in all explantations. RESULTS: Twenty-three of 1,490 eyes with PCPIOL implantation required removal and/or exchange. Of the explanted eyes, 17 were implanted with PCPIOLs for myopia (1.21% of all myopic corrections) and 6 were implanted with PCPIOLs for hyperopia (6.59% of all hyperopic corrections). The most common reason for removal and/or exchanges after implantation was inappropriate vault (10 of the 23 total removals and/or exchanges), followed by cataract development (7 of the 23 total removals and/or exchanges). A comparison of the biometric characteristics of eyes with PCPIOL removal and/ or exchange due to inappropriate vault with other PCPIOL implantations showed that anterior chamber depth, PCPIOL length, and white-to-white distance were significantly higher in the group of explanted eyes (P < .05). All eyes with high vault in myopic patients had a 13.2- or 13.7-mm length PCPIOL. CONCLUSIONS: The main reason for PCPIOL removal and/ or exchange is vault values outside the ideal limits and cataract development. Before ordering 13.2- and 13.7-mm long PCPIOLs, biometric data of both eyes and recommended PCPIOL sizes should be carefully reviewed.
引用
收藏
页码:e797 / e803
页数:7
相关论文
共 50 条
  • [21] Long-term results of implantation of phakic posterior chamber intraocular lenses
    Lackner, B
    Pieh, S
    Schmidinger, G
    Simader, C
    Franz, C
    Dejaco-Ruhswurm, I
    Skorpik, C
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2004, 30 (11): : 2269 - 2276
  • [22] Posterior chamber phakic intraocular lens
    Trindade, F
    JOURNAL OF REFRACTIVE SURGERY, 2001, 17 (02) : 155 - 155
  • [23] INCIDENCE OF POSTERIOR CAPSULE OPACIFICATION IN EYES WITH AND WITHOUT POSTERIOR CHAMBER INTRAOCULAR LENSES
    NISHI, O
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1986, 12 (05): : 519 - 522
  • [24] Changes of ocular biometry in eyes with posterior chamber phakic intraocular lens implantation
    Kayhan, B.
    Coskunseven, E.
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2022, 45 (04): : 377 - 383
  • [25] Collagen copolymer toric posterior chamber phakic intraocular lens in eyes with keratoconus
    Alfonso, Jose F.
    Fernandez-Vega, Luis
    Lisa, Carlos
    Fernandes, Paulo
    Gonzalez-Meijome, Jose M.
    Montes-Mico, Robert
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (06): : 906 - 916
  • [26] PHAKIC ANTERIOR-CHAMBER INTRAOCULAR LENSES
    BAIKOFF, G
    INTERNATIONAL OPHTHALMOLOGY CLINICS, 1991, 31 (01) : 75 - 86
  • [27] Choroidal neovascularization in phakic eyes with anterior chamber intraocular lenses to correct high myopia
    Ruiz-Moreno, JM
    de la Vega, C
    Ruiz-Moreno, O
    Alió, JL
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (02): : 270 - 274
  • [28] Retinal detachment in phakic eyes with anterior chamber intraocular lenses to correct severe myopia
    Ruiz-Moreno, JM
    Alió, JL
    Pérez-Santonja, JJ
    de la Hoz, F
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 1999, 127 (03) : 270 - 275
  • [29] Endothelial changes in phakic eyes with anterior chamber intraocular lenses to correct high myopia
    PerezSantonja, JJ
    Iradier, MT
    SanzIglesias, L
    Serrano, JM
    Zato, MA
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1996, 22 (08): : 1017 - 1022
  • [30] Retinal detachment in phakic eyes with anterior chamber intraocular lenses to correct severe myopia
    Kwok, AKH
    Young, AL
    Bhende, P
    Lam, DSC
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 1999, 128 (03) : 395 - 396