Reasons for Explantations of Posterior Chamber Phakic Intraocular Lenses in 1,490 Eyes

被引:0
|
作者
Coskunseven, Efekan [1 ,2 ]
Kayhan, Belma [3 ]
机构
[1] Zincirlikuyu Med Hosp, Refract Surg Dept, Istanbul, Turkiye
[2] Istanbul Yeni Yuzyil Univ, Fac Hlth Sci, Istanbul, Turkiye
[3] Univ Hlth Sci, Sultan II Abdulhamid Han Training & Res Hosp, Ophthalmol Dept, Istanbul, Turkiye
关键词
IMPLANTABLE COLLAMER LENS; OPTIMIZATION; MYOPIA;
D O I
10.3928/1081597X-20240913-03
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To investigate the reasons for the removal and/ or exchange of posterior chamber phakic intraocular lenses (PCPIOLs) and the outcomes of these procedures. METHODS: In this retrospective study, PCPIOL implantations performed between January 2015 and June 2023 in a single center were reviewed. The study group consisted of the files of eyes with removed and/or exchanged PCPIOL. Visual acuities, refraction errors, endothelial cell counts, and measurements of the vault before and after exchanges were recorded. Reasons for removal and/or exchange were evaluated. The tuck-and-pull technique was used in all explantations. RESULTS: Twenty-three of 1,490 eyes with PCPIOL implantation required removal and/or exchange. Of the explanted eyes, 17 were implanted with PCPIOLs for myopia (1.21% of all myopic corrections) and 6 were implanted with PCPIOLs for hyperopia (6.59% of all hyperopic corrections). The most common reason for removal and/or exchanges after implantation was inappropriate vault (10 of the 23 total removals and/or exchanges), followed by cataract development (7 of the 23 total removals and/or exchanges). A comparison of the biometric characteristics of eyes with PCPIOL removal and/ or exchange due to inappropriate vault with other PCPIOL implantations showed that anterior chamber depth, PCPIOL length, and white-to-white distance were significantly higher in the group of explanted eyes (P < .05). All eyes with high vault in myopic patients had a 13.2- or 13.7-mm length PCPIOL. CONCLUSIONS: The main reason for PCPIOL removal and/ or exchange is vault values outside the ideal limits and cataract development. Before ordering 13.2- and 13.7-mm long PCPIOLs, biometric data of both eyes and recommended PCPIOL sizes should be carefully reviewed.
引用
收藏
页码:e797 / e803
页数:7
相关论文
共 50 条
  • [1] Phakic posterior chamber intraocular lenses
    Kook, Daniel
    Mayer, Wolfgang J.
    Steinwender, Gernot
    Kohnen, Thomas
    SPEKTRUM DER AUGENHEILKUNDE, 2019, 33 (06) : 160 - 164
  • [2] Phakic posterior chamber intraocular lenses
    Werner, L
    Apple, DJ
    Pandey, SK
    Trivedi, RH
    Izak, AM
    Macky, TA
    INTERNATIONAL OPHTHALMOLOGY CLINICS, 2001, 41 (03) : 153 - 174
  • [3] Implantation of spheric phakic posterior chamber intraocular lenses in astigmatic eyes
    Bleckmann, H
    Keuch, RJ
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (05): : 805 - 809
  • [4] A review of posterior chamber phakic intraocular lenses
    Reinstein, Dan Z.
    MacGregor, Cheryl
    Archer, Timothy J.
    Gupta, Ruchi
    Potter, Joseph G.
    CURRENT OPINION IN OPHTHALMOLOGY, 2024, 35 (02) : 138 - 146
  • [5] Posterior chamber myopia lenses in phakic eyes
    Fechner, PU
    Haigis, W
    Wichmann, W
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1996, 22 (02): : 178 - 182
  • [6] Long-term endothelial changes in phakic eyes with posterior chamber intraocular lenses
    Dejaco-Ruhswurm, I
    Scholz, U
    Pieh, S
    Hanselmayer, G
    Lackner, B
    Italon, C
    Ploner, M
    Skorpik, C
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (09): : 1589 - 1593
  • [7] Dynamic Vaulting in Posterior Chamber Phakic Intraocular Lenses
    Gonzalez-Lopez, Felix
    Ortega-Usobiaga, Julio
    Bilbao-Calabuig, Rafael
    Mompean, Blas
    Bouza-Miguens, Carmen
    JOURNAL OF REFRACTIVE SURGERY, 2023, 39 (12) : 863 - 864
  • [9] Phakic posterior chamber intraocular lenses for the correction of high ametropia
    Belmont, SC
    Kim, DY
    Hatsis, AP
    Rozakis, GW
    Reinstein, DZ
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1997, 38 (04) : 2508 - 2508
  • [10] Posterior chamber phakic intraocular lenses after penetrating keratoplasty
    Alfonso, Jose F.
    Lisa, Carlos
    Abdelhamid, Abdelhamid
    Montes-Mico, Robert
    Poo-Lopez, Arancha
    Ferrer-Blasco, Teresa
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (07): : 1166 - 1173