Fabrication of low-cost heterogeneous anthropomorphic thyroid neck phantom for CT

被引:0
|
作者
Akbar, Obaidullah Ehtesham [1 ]
Hameed, Kamran [1 ]
Jaffar, Hussain [1 ]
Yousef, Mauth [1 ]
Hashim, Maryam Al [2 ,3 ]
机构
[1] Department of Biomedical Engineering, Imam Abdulrahman Bin Faisal University, PO Box 1982, 31441, Saudi Arabia
[2] Radiology Department, College of Medicine, Imam Abdulrahman Bin Faisal University, PO Box 1982, 31441, Saudi Arabia
[3] Medical Imaging Services Center, King Fahad Specialist Hospital Dammam, Dammam,32253, Saudi Arabia
关键词
Bone - Computerized tomography - Dosimeters - Dosimetry - Electron density measurement - Muscle - Phantoms;
D O I
10.1016/j.radphyschem.2025.112752
中图分类号
学科分类号
摘要
This article details the creation of a low-cost, heterogeneous anthropomorphic neck phantom with thyroid carcinoma for CT imaging. The phantom was designed to enable academic researchers and imaging system manufacturers to test and calibrate imaging machines and calculate dosimetry using thermoluminescent dosimeters in the neck and thyroid region. It was constructed using tissue-mimicking materials representing the thyroid, carcinoma, trachea, esophagus, spinal bones, muscle tissue, and adipose tissue. These materials were developed based on the elemental compositions outlined in the International Commission on Radiation Units and Measurements (ICRU) Report 44 and the International Commission on Radiological Protection Report 110 (ICRP). The phantom was modeled and segmented from a CT scan of a 52-year-old female thyroid cancer patient using segmentation software. Segmented parts were 3D printed and molded with silicone caulking, followed by the fabrication of tissue-mimicking materials cast into a cylinder filled with muscle tissue material. Validation showed that the tissue-mimicking materials generally achieved appropriate ionizing radiation parameters, such as tissue density, electron density, and effective atomic number. However, notable discrepancies were observed in the densities of the muscle and spinal bone materials compared to reference values. Mass attenuation coefficient (μ/ρ) graphs generated via the XCOM database showed minimal deviations from reference data provided by the ICRU and the ICRP. Validation under a standard thyroid imaging protocol on a CT machine demonstrated reasonable anatomical accuracy and Hounsfield unit ratios between tissues. However, challenges in achieving consistent material properties for muscle and spinal bone materials were identified, suggesting areas for future improvement. © 2025 Elsevier Ltd
引用
收藏
相关论文
共 50 条
  • [41] Design and Fabrication of a Low-Cost Mobile Antenna for Low VHF
    Rafaei-Booket, Mahmood
    Hasibi-Taheri, Sina
    IETE JOURNAL OF RESEARCH, 2023, 69 (08) : 5701 - 5707
  • [42] The Development of Custom, Low-Cost, Anthropomorphic Phantoms Constructed Via Additive Manufacturing
    Pruett, J.
    Muller, L.
    Ahmad, S.
    Johnson, D.
    MEDICAL PHYSICS, 2017, 44 (06) : 2878 - 2878
  • [43] Analysis of a low-cost anthropomorphic sensory platform for the world first minibus test
    Stopforth, Riaan
    Proctor-Parker, Craig
    Davrajh, Shaniel
    JOURNAL OF ENGINEERING DESIGN AND TECHNOLOGY, 2019, 17 (02) : 434 - 455
  • [44] Design and Fabrication of a Multi-Functional Neck and Thyroid Phantom for Medical Dosimetry and Calibration
    Mehdizadeh, S.
    Sina, S.
    Karimipourfard, M.
    Lotfalizadeh, F.
    Faghihi, R.
    Babaei, A.
    MEDICAL PHYSICS, 2014, 41 (06)
  • [45] Cost-efficient anthropomorphic head phantom for quantitative image quality assessment in cone beam CT
    Wang, Yichao
    Dankelman, Jenny
    Ruijters, Danny
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2022, 8 (06)
  • [46] Fabrication of low-cost realistic three-dimensional static kidney phantom for ultrasound-guided biopsy applications
    Fohely, Firas
    Oglat, Ammar A.
    Sabarna, Khaled
    Shweiki, Zakaria
    Hamoudeh, Bayan
    Shalaan, Rulin
    JOURNAL OF MEDICAL ULTRASOUND, 2022, 30 (01) : 36 - 40
  • [47] Different approaches for fabrication of low-cost electrochemical sensors
    Stefano, Jessica Santos
    Orzari, Luiz Otavio
    Silva-Neto, Habdias Araujo
    de Ataide, Vanessa Neiva
    Mendes, Leticia Francine
    Tomazelli Coltro, Wendell Karlos
    Cesar Paixao, Thiago Regis Longo
    Janegitz, Bruno Campos
    CURRENT OPINION IN ELECTROCHEMISTRY, 2022, 32
  • [48] Low-cost 3D print - based phantom fabrication to facilitate interstitial prostate brachytherapy training program
    Chiu, Tsuicheng
    Xiong, Zhenyu
    Parsons, David
    Folkert, Michael R.
    Medin, Paul M.
    Hrycushko, Brian
    BRACHYTHERAPY, 2020, 19 (06) : 800 - 811
  • [49] Low-Cost QA Benchmark for Fused Filament Fabrication
    Akande, Stephen Oluwashola
    Dalgarno, Kenny W.
    Munguia, Javier
    3D PRINTING AND ADDITIVE MANUFACTURING, 2015, 2 (02) : 78 - 84
  • [50] Low-cost and cleanroom-free fabrication of microneedles
    Hojatollah Rezaei Nejad
    Aydin Sadeqi
    Gita Kiaee
    Sameer Sonkusale
    Microsystems & Nanoengineering, 4