Fabrication of low-cost heterogeneous anthropomorphic thyroid neck phantom for CT
被引:0
|作者:
Akbar, Obaidullah Ehtesham
[1
]
Hameed, Kamran
[1
]
Jaffar, Hussain
[1
]
Yousef, Mauth
[1
]
Hashim, Maryam Al
[2
,3
]
机构:
[1] Department of Biomedical Engineering, Imam Abdulrahman Bin Faisal University, PO Box 1982, 31441, Saudi Arabia
[2] Radiology Department, College of Medicine, Imam Abdulrahman Bin Faisal University, PO Box 1982, 31441, Saudi Arabia
[3] Medical Imaging Services Center, King Fahad Specialist Hospital Dammam, Dammam,32253, Saudi Arabia
关键词:
Bone - Computerized tomography - Dosimeters - Dosimetry - Electron density measurement - Muscle - Phantoms;
D O I:
10.1016/j.radphyschem.2025.112752
中图分类号:
学科分类号:
摘要:
This article details the creation of a low-cost, heterogeneous anthropomorphic neck phantom with thyroid carcinoma for CT imaging. The phantom was designed to enable academic researchers and imaging system manufacturers to test and calibrate imaging machines and calculate dosimetry using thermoluminescent dosimeters in the neck and thyroid region. It was constructed using tissue-mimicking materials representing the thyroid, carcinoma, trachea, esophagus, spinal bones, muscle tissue, and adipose tissue. These materials were developed based on the elemental compositions outlined in the International Commission on Radiation Units and Measurements (ICRU) Report 44 and the International Commission on Radiological Protection Report 110 (ICRP). The phantom was modeled and segmented from a CT scan of a 52-year-old female thyroid cancer patient using segmentation software. Segmented parts were 3D printed and molded with silicone caulking, followed by the fabrication of tissue-mimicking materials cast into a cylinder filled with muscle tissue material. Validation showed that the tissue-mimicking materials generally achieved appropriate ionizing radiation parameters, such as tissue density, electron density, and effective atomic number. However, notable discrepancies were observed in the densities of the muscle and spinal bone materials compared to reference values. Mass attenuation coefficient (μ/ρ) graphs generated via the XCOM database showed minimal deviations from reference data provided by the ICRU and the ICRP. Validation under a standard thyroid imaging protocol on a CT machine demonstrated reasonable anatomical accuracy and Hounsfield unit ratios between tissues. However, challenges in achieving consistent material properties for muscle and spinal bone materials were identified, suggesting areas for future improvement. © 2025 Elsevier Ltd
引用
收藏
相关论文