Acoustic Radiation Force Optical Coherence Elastography of the Crystalline Lens: Safety

被引:0
|
作者
Zevallos-Delgado, Christian [1 ]
Mekonnen, Taye Tolu [1 ]
Duvvuri, Chaitanya [2 ]
Rohman, Leana [3 ,4 ]
Schumacher, Justin [5 ]
Singh, Manmohan [1 ]
Aglyamov, Salavat R. [6 ]
Twa, Michael D. [2 ]
Parel, Jean-Marie [3 ,4 ]
Scarcelli, Giuliano [5 ]
Manns, Fabrice [3 ,4 ]
Larin, Kirill V. [1 ]
机构
[1] Univ Houston, Dept Biomed Engn, 2517 Cullen Blvd,Room 2027, Houston, TX 77204 USA
[2] Univ Houston, Coll Optometry, Houston, TX USA
[3] Univ Miami, Bascom Palmer Eye Inst, Ophtalm Biophys Ctr, Miller Sch Med, Miami, FL USA
[4] UNIV MIAMI, COLL ENGN, Dept Biomed Engn, MIAMI, FL USA
[5] Univ Maryland, Bioengn Brain & Behav Inst, Fischell Dept, College Pk, MD USA
[6] Univ Houston, Dept Mech Engn, Houston, TX USA
来源
基金
美国国家卫生研究院;
关键词
crystalline lens; acoustic radiation force; safety; optical coherence elastography; PROBE;
D O I
10.1167/tvst.13.12.36
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To assess the safety of acoustic radiation force optical coherence elastography in the crystalline lens in situ. Methods: Acoustic radiation force (ARF) produced by an immersion single-element ultrasound transducer (nominal frequency = 3.5 MHz) was characterized using a needle hydrophone and used for optical coherence elastography (OCE) of the crystalline lens. Preamplified signals at 50, 100, 250, 500, 750, 1000, and 1250 mV peak amplitude were tested on ex vivo porcine eyes (n = 21). Three-dimensional optical coherence tomography (OCT) and confocal microscopy images were acquired before and after ARF exposure to each signal amplitude to determine damage. Results: The acoustic intensity of the ultrasound transducer at 100-mV preamplified peak amplitude input demonstrated a signal-to-noise ratio high enough for tracking elastic wave propagation in the lens and spatial-peak pulse-average (SPPA) intensity of 24.1 W/cm(2) and mechanical index (MI) of 0.46. The SPPA intensity was lower than the U.S. Food and Drug Administration (FDA) safety limit (28 W/cm(2)), but the MI was twice the safety limit (0.23). OCT structural and confocal microscopy images showed damage only at levels exceeding 1150 W/cm(2) and 3.2 for SPPA intensity and MI, respectively. Conclusions: OCT and confocal microscopy showed that, even when the intensity exceeded FDA recommendations (>100 mV), no noticeable damage was observed. Although a further reduction in acoustic intensity is necessary to meet FDA safety limits, ARF-based elastography shows promise for safe clinical translation in quantitatively characterizing lenticular biomechanical properties. Translational Relevance: This work assessed the safety standards for acoustic radiation force to be used in human lens elastography according to the FDA safety limits.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Shear wave elastography method combining phase-sensitive optical coherence tomography and coded acoustic radiation force
    Thu-Mai Nguyen
    Song, Shaozhen
    Arnal, Bastien
    Wong, Emily Y.
    Wang, Ruikang K.
    O'Donnell, Matthew
    2014 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2014, : 651 - 654
  • [42] Tissue-mimicking bladder wall phantoms for evaluating acoustic radiation force-optical coherence elastography systems
    Ejofodomi, O'tega A.
    Zderic, Vesna
    Zara, Jason M.
    MEDICAL PHYSICS, 2010, 37 (04) : 1440 - 1448
  • [43] Multifocal acoustic radiation force-based reverberant optical coherence elastography for evaluation of ocular globe biomechanical properties
    Mekonnen, Taye
    Zevallos-Delgado, Christian
    Singh, Manmohan
    Aglyamov, Salavat R.
    Larin, Kirill V.
    JOURNAL OF BIOMEDICAL OPTICS, 2023, 28 (09)
  • [44] Acoustic radiation force optical coherence elastography for evaluating mechanical properties of soft condensed matters and its biological applications
    Liu, Hsiao-Chuan
    Kijanka, Piotr
    Urban, Matthew W.
    JOURNAL OF BIOPHOTONICS, 2020, 13 (03)
  • [45] Novel acoustic radiation force optical coherence elastography based on ultrasmall ultrasound transducer for biomechanics evaluation of in vivo cornea
    Zhu, Yirui
    Zhao, Yanzhi
    Shi, Jiulin
    Alvarez-arenas, Tomas E.
    Yang, Hongwei
    Cai, Hongling
    Zhang, Dong
    He, Xingdao
    Wu, Xiaoshan
    JOURNAL OF BIOPHOTONICS, 2023, 16 (08)
  • [46] Miniature probe for mechanical properties of vascular lesions using acoustic radiation force optical coherence elastography (Conference Presentation)
    Qu, Yueqiao
    Ma, Teng
    He, Youmin
    Yu, Mingyue
    Li, Rui
    Zhu, Jiang
    Dai, Cuixia
    Piao, Zhonglie
    Shung, K. Kirk
    Zhou, Qifa
    Chen, Zhongping
    OPTICAL ELASTOGRAPHY AND TISSUE BIOMECHANICS III, 2016, 9710
  • [47] Biomechanical properties of crystalline lens as a function of intraocular pressure assessed noninvasively by Optical Coherence Elastography
    Wu, Chen
    Aglyamov, Salavat R.
    Liu, Chih-Hao
    Han, Zhaolong
    Singh, Manmohan
    Larin, Kiri V.
    OPTHALMIC TECHNOLOGIES XXVII, 2017, 10045
  • [48] Assessing the biomechanical properties of the porcine crystalline lens as a function of intraocular pressure with optical coherence elastography
    Wu, Chen
    Aglyamov, Salavat R.
    Han, Zhaolong
    Singh, Manmohan
    Liu, Chih-Hao
    Larin, Kirill, V
    BIOMEDICAL OPTICS EXPRESS, 2018, 9 (12): : 6455 - 6466
  • [49] Lorentz Force Megahertz Optical Coherence Elastography
    Wu, Chen
    Singh, Manmohan
    Han, Zhaolong
    Raghunathan, Raksha
    Liu, Chih-Hao
    Lia, Jiasong
    Schill, Alexander
    Larin, Kirill V.
    OPTICAL ELASTOGRAPHY AND TISSUE BIOMECHANICS III, 2016, 9710
  • [50] Spectroscopic photonic force optical coherence elastography
    Lin, Yuechuan
    Leartprapun, Nichaluk
    Adie, Steven G.
    OPTICS LETTERS, 2019, 44 (19) : 4897 - 4900