3D printed titanium banana interbody cages versus titanium-coated PEEK bullet cages for TLIF

被引:0
|
作者
Jacob, Connor C. [1 ,3 ]
Eaton, Ryan [2 ]
Ward, Jacob [1 ]
Sette, Katelyn [1 ]
Wilson, Seth [1 ]
Weber, Matthieu D. [1 ]
Duru, Olivia [1 ]
Keister, Alexander [1 ]
Harrigan, Markus E. [1 ]
Grossbach, Andrew J. [2 ]
Viljoen, Stephanus [2 ]
机构
[1] OHIO STATE UNIV, Coll Med, 1645 Neil Ave, COLUMBUS, OH 43210 USA
[2] Ohio State Univ, Dept Neurosurg, 410 W 10th Ave, Columbus, OH 43210 USA
[3] Ohio State Univ, Coll Med, Columbus, OH 43210 USA
关键词
TLIF; 3D printed titanium; PEEK; fusion; subsidence; LUMBAR FUSION SURGERY; STENOSIS; SPONDYLOLISTHESIS; METAANALYSIS; ROUGHNESS; DISEASE; LEVEL;
D O I
10.1016/j.clineuro.2025.108731
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Introduction: Lumbar degenerative spinal disease is a common, major cause of pain and disability. Titanium and polyetheretherketone (PEEK) are popular materials for interbody implants although evidence is mixed on which material is superior in terms of fusion and subsidence. The purpose of this study was to evaluate the clinical outcome of 3D printed titanium (3DPT) cages in patients undergoing TLIFs, as well as complication profiles based on widely used outcome metrics and reoperation events. Methods: A retrospective review was conducted for patients receiving 1- or 2-level TLIF at an academic medical center between January 2018 and May 2022. Patients were divided into two cohorts according to the material of interbody cage(s), either 3DPT banana or titanium-coated PEEK bullet. Radiographs, patient-reported outcome measures (PROMs), and complications were analyzed and compared. All included patients had radiographic and clinical follow-up of at least one year. Results: 200 patients with 277 interbody cage-implanted levels were included. Patients received either 3DPT (n = 140) or PEEK (n = 60) interbody cages with 202 and 75 instrumented vertebral levels per cohort, respectively. At one year, the 3DPT cohort demonstrated a higher fusion rate of 93.3 % compared to the PEEK cohort's fusion rate of 73.2 % (p < 0.0001). Subsidence rates were 6.0 % and 25.0 % for the 3DPT and PEEK groups, respectively (p < 0.0001). Conclusion: While 3DPT and PEEK interbody cages demonstrated few adverse events at short- and long-term follow-up, 3DPT exhibited a higher rate of fusion and lower rate of subsidence at one year.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Subsidence Rates Associated With Porous 3D-Printed Versus Solid Titanium Cages in Transforaminal Lumbar Interbody Fusion
    Toop, Nathaniel
    Dhaliwal, Joravar
    Grossbach, Andrew
    Gibbs, David
    Reddy, Nihaal
    Keister, Alexander
    Mallory, Noah
    Xu, David
    Viljoen, Stephanus
    GLOBAL SPINE JOURNAL, 2024, 14 (07) : 1889 - 1898
  • [22] Titanium (Ti) cages may be superior to polyetheretherketone (PEEK) cages in lumbar interbody fusion: a systematic review and meta-analysis of clinical and radiological outcomes of spinal interbody fusions using Ti versus PEEK cages
    Jun-Hao Tan
    Chin Kai Cheong
    Hwee Weng Dennis Hey
    European Spine Journal, 2021, 30 : 1285 - 1295
  • [23] Distractable titanium cages versus PEEK cages versus iliac crest bone grafts for the replacement of cervical vertebrae
    Koenig, Stefan Alexander
    Spetzger, Uwe
    MINIMALLY INVASIVE THERAPY & ALLIED TECHNOLOGIES, 2014, 23 (02) : 102 - 105
  • [24] Titanium coated Polyether-ether-ketone - Cages versus full Titanium
    Altorfer, Franziska
    Laux, Christoph J.
    Graf, Dimitri
    Farshad, Mazda
    Spirig, Jose Miguel
    SWISS MEDICAL WEEKLY, 2023, 153 : 70S - 71S
  • [25] Titanium Cages versus Polyetheretherketone Cages in Interbody Fusions: A Meta-Analysis of Clinical and Radiographic Outcomes
    Daher, Mohammad
    Aoun, Marven
    Farhat, Charbel
    Kreichati, Gaby
    Kharrat, Khalil
    Daniels, Alan H.
    Sebaaly, Amer
    WORLD NEUROSURGERY, 2025, 193 : 15 - 25
  • [26] Radiological Outcomes of Posterior Lumbar Interbody Fusion Using a Titanium-coated PEEK Cage
    Manabe, Hiroaki
    Sakai, Toshinori
    Morimoto, Masatoshi
    Tezuka, Fumitake
    Yamashita, Kazuta
    Takata, Yoichiro
    Sairyo, Koichi
    JOURNAL OF MEDICAL INVESTIGATION, 2019, 66 (1-2): : 119 - 122
  • [27] Early Fusion Status after Posterior Lumbar Interbody Fusion with Cortical Bone Trajectory Screw Fixation: A Comparison of Titanium-Coated Polyetheretherketone Cages and Carbon Polyetheretherketone Cages
    Sakaura, Hironobu
    Ohnishi, Atsunori
    Yamagishi, Akira
    Ohwada, Tetsuo
    ASIAN SPINE JOURNAL, 2019, 13 (02) : 248 - 253
  • [28] Advancements in Custom 3D-Printed Titanium Interbody Spinal Fusion Cages and Their Relevance in Personalized Spine Care
    Lewandrowski, Kai-Uwe
    Vira, Shaleen
    Elfar, John C.
    Lorio, Morgan P.
    JOURNAL OF PERSONALIZED MEDICINE, 2024, 14 (08):
  • [29] Comparison between Three-Dimensional Printed Titanium and PEEK Cages for Cervical and Lumbar Interbody Fusion: A Prospective Controlled Trial
    Deng, Zhipeng
    Zou, Qiang
    Wang, Lei
    Wang, Liang
    Xiu, Peng
    Feng, Ganjun
    Song, Yueming
    Yang, Xi
    ORTHOPAEDIC SURGERY, 2023, 15 (11) : 2889 - 2900
  • [30] Trabecular Bone Remodeling After Posterior Lumbar Interbody Fusion: Comparison of Three-Dimensional Porous Tantalum and Titanium-Coated Polyetheretherketone Interbody Cages
    Segi, Naoki
    Nakashima, Hiroaki
    Shinjo, Ryuichi
    Kagami, Yujiro
    Machino, Masaaki
    Ito, Sadayuki
    Ouchida, Jun
    Morishita, Kazuaki
    Oishi, Ryotaro
    Yamauchi, Ippei
    Imagama, Shiro
    GLOBAL SPINE JOURNAL, 2024, 14 (07) : 2106 - 2115