Collimated active spot-scanning IMPT vs VMAT for lung SBRT: Dosimetric and robustness comparison

被引:0
|
作者
Trombetta, Luca [1 ]
Faccenda, Valeria [2 ]
Magro, Giuseppe [1 ]
Panizza, Denis [2 ]
Russo, Stefania [1 ]
Bianchi, Sofia Paola [3 ,4 ]
Arcangeli, Stefano [3 ,4 ]
De Ponti, Elena [2 ,3 ]
Orlandi, Ester [5 ]
Ciocca, Mario [1 ]
机构
[1] Fdn CNAO, Med Phys Dept, Pavia, Italy
[2] Fdn IRCCS San Gerardo Tintori, Med Phys Dept, Monza, Italy
[3] Univ Milano Bicocca, Fac Med & Surg, Milan, Italy
[4] Fdn IRCCS San Gerardo Tintori, Radiotherapy Dept, Monza, Italy
[5] Fdn CNAO, Dept Radiotherapy, Pavia, Italy
关键词
IMPT; lung SBRT; collimated active spot-scanning;
D O I
暂无
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
1748
引用
收藏
页码:S4652 / S4653
页数:3
相关论文
共 32 条
  • [21] Dosimetric Robustness Comparisons of Treating Around and Through the Metallic-Ports Embedded Tissue Expanders of Post-Mastectomy Breast Patients Using Spot-Scanning Proton Beams
    Chen, C.
    Del Rosario, G.
    Han, Z.
    Rydquist, L.
    Liu, H.
    Zeng, C.
    Sine, K.
    Lee, C.
    Cahlon, O.
    Mah, D.
    MEDICAL PHYSICS, 2018, 45 (06) : E431 - E431
  • [22] Is proton beam therapy ready for single fraction spine SBRS? - a feasibility study to use spot-scanning proton arc (SPArc) therapy to improve the robustness and dosimetric plan quality
    Liu, Gang
    Li, Xiaoqiang
    Qin, An
    Zhou, Jun
    Zheng, Weili
    Zhao, Lewei
    Han, Jun
    Zhang, Sheng
    Yan, Di
    Stevens, Craig
    Grills, Inga
    Ding, Xuanfeng
    ACTA ONCOLOGICA, 2021, 60 (05) : 653 - 657
  • [23] NTCP modeling analysis of acute hematologic toxicity in whole pelvic radiation therapy for gynecologic malignancies - A dosimetric comparison of IMRT and spot-scanning proton therapy (SSPT)
    Yoshimura, Takaaki
    Kinoshita, Rumiko
    Onodera, Shunsuke
    Toramatsu, Chie
    Suzuki, Ryusuke
    Ito, Yoichi M.
    Takao, Seishin
    Matsuura, Taeko
    Matsuzaki, Yuka
    Umegaki, Kikuo
    Shirato, Hiroki
    Shimizu, Shinichi
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2016, 32 (09): : 1095 - 1102
  • [24] What is the appropriate size criterion for proton radiotherapy for hepatocellular carcinoma? A dosimetric comparison of spot-scanning proton therapy versus intensity-modulated radiation therapy
    Toramatsu, Chie
    Katoh, Norio
    Shimizu, Shinichi
    Nihongi, Hideaki
    Matsuura, Taeko
    Takao, Seishin
    Miyamoto, Naoki
    Suzuki, Ryusuke
    Sutherland, Kenneth
    Kinoshita, Rumiko
    Onimaru, Rikiya
    Ishikawa, Masayori
    Umegaki, Kikuo
    Shirato, Hiroki
    RADIATION ONCOLOGY, 2013, 8
  • [25] Spot-scanning beam proton therapy vs intensity-modulated radiation therapy for ipsilateral head and neck malignancies: A treatment planning comparison
    Kandula, Shravan
    Zhu, Xiaorong
    Garden, Adam S.
    Gillin, Michael
    Rosenthal, David I.
    Ang, Kie-Kian
    Mohan, Radhe
    Amin, Mayankkumar V.
    Garcia, John A.
    Wu, Richard
    Sahoo, Narayah
    Frank, Steven J.
    MEDICAL DOSIMETRY, 2013, 38 (04) : 390 - 394
  • [26] NTCP Modeling Analysis of Acute Hematologic Toxicity in Whole-Pelvic Radiation Therapy for Gynecologic Malignancies: A Dosimetric Comparison of IMRT and Spot-Scanning Proton Therapy
    Yoshimura, T.
    Kinoshita, R.
    Onodera, S.
    Toramatsu, C.
    Suzuki, R.
    Ito, Y. M.
    Takao, S.
    Matsuura, T.
    Matsuzaki, Y.
    Shimizu, S.
    Umegaki, K.
    Shirato, H.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2015, 93 (03): : E254 - E254
  • [27] Effectiveness of Using Spot-ScanningProton Arc (SPArc) Therapy to Mitigate the Motion Interplay Effect in Lung Stereotactic Bodyradiotherapy (SBRT): A Quantitative Comparison Study between IMPT Vs SPArc Based a Digital Phantom
    Liu, G.
    Li, X.
    Qin, A.
    Grills, I.
    Stevens, C.
    Yan, D.
    Zhang, S.
    Li, Q.
    Quan, H.
    Kabolizadeh, P.
    Ding, X.
    MEDICAL PHYSICS, 2019, 46 (06) : E249 - E249
  • [28] Comparison of organ-at-risk sparing and plan robustness for spot-scanning proton therapy and volumetric modulated arc photon therapy in head-and-neck cancer
    Barten, Danique L. J.
    Tol, Jim P.
    Dahele, Max
    Slotman, Ben J.
    Verbakel, Wilko F. A. R.
    MEDICAL PHYSICS, 2015, 42 (11) : 6589 - 6598
  • [29] Comparison of VMAT Vs Arc Treatment Plans for Patients Undergoing SBRT of Early-Stage Non-Small Cell Lung Cancer (NSCLC)
    Neicu, T.
    Chan, P.
    Valakh, V.
    Bizhan, M.
    Miyamoto, C.
    Li, S.
    MEDICAL PHYSICS, 2012, 39 (06) : 3855 - 3855
  • [30] High-dose hypofractionated pencil beam scanning carbon ion radiotherapy for lung tumors: Dosimetric impact of different spot sizes and robustness to interfractional uncertainties
    Mastella, Edoardo
    Mirandola, Alfredo
    Russo, Stefania
    Vai, Alessandro
    Magro, Giuseppe
    Molinelli, Silvia
    Barcellini, Amelia
    Vitolo, Viviana
    Orlandi, Ester
    Ciocca, Mario
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2021, 85 : 79 - 86