Structure Optimization of 3-D ECT Sensor With a High Height-to-Diameter Ratio

被引:0
|
作者
Guo, Aofang [1 ]
Yang, Daoye [1 ]
Zhang, Shuxian [1 ]
机构
[1] Nanjing Tech Univ, Coll Elect Engn & Control Sci, Nanjing 211816, Jiangsu, Peoples R China
基金
中国国家自然科学基金;
关键词
Sensors; Imaging; Electrodes; Image reconstruction; Image sensors; Capacitance; Shape; Three-dimensional displays; Accuracy; Inverse problems; Adaptive total variation regularized-projected gradient descent (ATV-PGD); capacitive sensors; electrical capacitance tomography; electrode shape; height-to-diameter ratio (HDR); ELECTRICAL CAPACITANCE TOMOGRAPHY; IMAGE-RECONSTRUCTION ALGORITHM; SOLIDS; SIMULATION; RISER;
D O I
10.1109/JSEN.2024.3520968
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The axial flow characteristics are crucial for studying flow in pneumatic conveying systems and fluidized beds. The main challenge in electrical capacitance tomography (ECT) axial imaging is the limited number of electrodes, which typically results in only 2-4 planes of axial coverage, leading to a restricted imaging range. This limitation significantly hampers the ability to achieve comprehensive axial imaging, constraining the overall monitoring range in the system. To enhance the axial imaging capability of 3-D ECT, the structure of a 32-electrode, eight-plane ECT sensor is optimized to increase its axial length, thereby extending the imaging range while maintaining imaging quality. Simulations were conducted for three different height-to-diameter ratios (HDRs) of 7.8, 14.3, and 20.7. The sensor structure is optimized in terms of electrode shape, length, spacing, and arrangement. Adaptive total variation regularized-projected gradient descent (ATV-PGD) image reconstruction algorithm is proposed to capture internal structural details accurately while effectively suppressing noise and artifacts. This is achieved by optimizing an objective function that integrates data consistency and image smoothness, and the algorithm is designed to maximize the axial imaging length while ensuring that the overall imaging quality along the sections is maintained. The imaging effectiveness of the sensor for continuous and intermittent flows is validated using predetermined cylinder flow and uniformly spaced sphere flow. Final experiments confirm the efficacy of the proposed algorithm and sensor structure in achieving high-quality axial imaging.
引用
收藏
页码:6511 / 6521
页数:11
相关论文
共 50 条
  • [1] Optimization of height-to-diameter ratio for an accelerator-driven system
    Kim, Y
    Park, WS
    Song, TY
    Park, CK
    NUCLEAR SCIENCE AND ENGINEERING, 2003, 143 (02) : 141 - 157
  • [2] The Fabrication Method of High Height-to-Diameter Ratio Micro-Wineglass Resonators
    Xie, Jianbing
    Ren, Sen
    Shen, Qiang
    Chen, Lei
    Xie, Hui
    Yuan, Weizheng
    2018 IEEE 8TH INTERNATIONAL NANOELECTRONICS CONFERENCES (INEC), 2018, : 45 - 46
  • [3] Virtual Orthogonal Optimization in Upsetting of Cone End Billet with Large Height-To-Diameter Ratio
    Wang, Chengpeng
    Fan, Junkai
    Zhao, Wu
    Liu, Wei
    MATERIALS SCIENCE-MEDZIAGOTYRA, 2023, 29 (01): : 21 - 26
  • [4] Influence of Digester Height-to-Diameter Ratio on Biomethanation of Market Vegetable Wastes
    Ganas, Dennis E.
    MINDANAO JOURNAL OF SCIENCE AND TECHNOLOGY, 2022, 20 (02): : 142 - 156
  • [5] Influence of the height-to-diameter ratio on turbulent mixed convection in vertical cylinders
    Gyeong-Uk Kang
    Bum-Jin Chung
    Heat and Mass Transfer, 2012, 48 : 1183 - 1191
  • [6] Influence of the height-to-diameter ratio on turbulent mixed convection in vertical cylinders
    Kang, Gyeong-Uk
    Chung, Bum-Jin
    HEAT AND MASS TRANSFER, 2012, 48 (07) : 1183 - 1191
  • [7] INFLUENCE OF HEIGHT-TO-DIAMETER RATIO SAMPLES AND HUMIDITY ON THE STRENGTH PROPERTIES OF SANDSTONES
    Bukowska, Miroslawa
    SCIENCE AND TECHNOLOGIES IN GEOLOGY, EXPLORATION AND MINING, SGEM 2015, VOL III, 2015, : 391 - 398
  • [8] TALL LIQUID PILLAR WITH A HEIGHT-TO-DIAMETER RATIO ABOVE PI - HYDRODYNAMIC STABILITY RATIO
    GROSSE, AV
    JOURNAL OF INORGANIC & NUCLEAR CHEMISTRY, 1971, 33 (03): : 777 - &
  • [9] Height-to-Diameter Ratio and Porosity Strongly Influence Bulk Compressive Mechanical Properties of 3D-Printed Polymer Scaffolds
    Contreras Raggio, Jose, I
    Toro Arancibia, Carlos
    Millan, Carola
    Ploeg, Heidi-Lynn
    Aiyangar, Ameet
    Vivanco, Juan F.
    POLYMERS, 2022, 14 (22)
  • [10] SOLID FEEDING MECHANISM AND ITS APPLICATION ON CASTINGS WITH LARGE HEIGHT-TO-DIAMETER RATIO
    Chen Longfei
    Luan Yikun
    Li Dianzhong
    Li Yiyi
    ACTA METALLURGICA SINICA, 2016, 52 (12) : 1510 - 1516