Evaluating the Accuracy of Smartphone-Based Photogrammetry and Videogrammetry in Facial Asymmetry Measurement

被引:0
|
作者
Coelho, Luiz Carlos Teixeira [1 ,2 ]
Pinho, Matheus Ferreira Coelho [1 ]
de Carvalho, Flavia Martinez
Franco, Ana Luiza Meneguci Moreira
Quispe-Enriquez, Omar C. [2 ]
Altonaga, Francisco Airasca [1 ]
Lerma, Jose Luis [2 ]
机构
[1] Univ Estado Rio De Janeiro, Sch Engn, Photogrammetry & Remote Sensing Lab, Lab Fotogrametria & Sensoriamento Remoto LFSR, Rua Sao Francisco Xavier 524,PJLF Sala 4044F, BR-20550013 Rio De Janeiro, RJ, Brazil
[2] Univ Politecn Valencia, Dept Cartog Engn Geodesy & Photogrammetry, Photogrammetry & Laser Scanner Res Grp GIFLE, Camino Vera S-N, Valencia 46022, Spain
来源
SYMMETRY-BASEL | 2025年 / 17卷 / 03期
关键词
smartphone-based photogrammetry; 3D scanning; cell phone; facial landmarks; facial anthropometry; dysmorphology; SEXUAL-DIMORPHISM; SYMMETRY; DESIGN; AGE;
D O I
10.3390/sym17030376
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Facial asymmetry presents a significant challenge for health practitioners, including physicians, dentists, and physical therapists. Manual measurements often lack the precision needed for accurate assessments, highlighting the appeal of imaging technologies like structured light scanners and photogrammetric systems. However, high-end commercial systems remain cost prohibitive, especially for public health services in developing countries. This study aims to evaluate cell-phone-based photogrammetric methods for generating 3D facial models to detect facial asymmetries. For this purpose, 15 patients had their faces scanned with the ACADEMIA 50 3D scanner, as well as with cell phone images and videos using photogrammetry and videogrammetry, resulting in 3D facial models. Each 3D model (coming from a 3D scanner, photogrammetry, and videogrammetry) was half-mirrored to analyze dissimilarities between the two ideally symmetric face sides using Hausdorff distances between the two half-meshes. These distances were statistically analyzed through various measures and hypothesis tests. The results indicate that, in most cases, both photogrammetric and videogrammetric approaches are as reliable as 3D scanning for detecting facial asymmetries. The benefits and limitations of using images, videos, and 3D scanning are also presented.
引用
收藏
页数:25
相关论文
共 50 条
  • [31] Smartphone-Based Visual Acuity Measurement for Screening and Clinical Assessment
    Brady, Christopher J.
    Eghrari, Allen O.
    Labrique, Alain B.
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2015, 314 (24): : 2682 - +
  • [32] Assessment of a smartphone-based application for diabetic foot ulcer measurement
    Kuang, Beatrice
    Pena, Guilherme
    Szpak, Zygmunt
    Edwards, Suzanne
    Battersby, Ruth
    Cowled, Prue
    Dawson, Joseph
    Fitridge, Robert
    WOUND REPAIR AND REGENERATION, 2021, 29 (03) : 460 - 465
  • [33] Development of Smartphone-based Non-Invasive Hemoglobin Measurement
    Dewantoro, Putut
    Gandana, Clinton Elian
    Zakaria, Resti Oktia Rahman Hasballah
    Irawan, Yoke Saadia
    2018 INTERNATIONAL SYMPOSIUM ON ELECTRONICS AND SMART DEVICES (ISESD 2018): SMART DEVICES FOR BIG DATA ANALYTIC AND MACHINE LEARNING, 2018, : 28 - 33
  • [34] Systematic investigation of the measurement error structure in a smartphone-based spectrophotometer
    Matinrad, Fereshteh
    Kompany-Zareh, Mohsen
    Omidikia, Nematollah
    Dadashi, Mahsa
    ANALYTICA CHIMICA ACTA, 2020, 1129 : 98 - 107
  • [35] Accuracy of smartphone-based evaluation of Emergent Large Vessel Occlusion on CTA
    Hidlay, Douglas T.
    McTaggart, Ryan A.
    Baird, Grayson
    Yaghi, Shadi
    Hemendinger, Morgan
    Tung, Eric L.
    Dibiasio, Eleanor L.
    Haas, Richard A.
    Jayaraman, Mahesh, V
    CLINICAL NEUROLOGY AND NEUROSURGERY, 2018, 171 : 135 - 138
  • [36] Accuracy Of A Smartphone-based "App" For The Assessement Of Sedentary And More Active Behaviors
    Toledo, Meynard John L.
    Hekler, Eric
    Hollingshead, Kevin
    Epstein, Dana R.
    Ainsworth, Barbara A.
    Buman, Matthew P.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2016, 48 (05): : 327 - 327
  • [37] Design and Implementation of Smartphone-Based Tear Volume Measurement System
    Okazaki, Yoshiro
    Takenaga, Tatsuki
    Miyake, Taku
    Iwabuchi, Mamoru
    Okubo, Toshiyuki
    Yokoi, Norihiko
    INTERNET OF THINGS TECHNOLOGIES FOR HEALTHCARE, HEALTHYIOT 2016, 2016, 187 : 155 - 158
  • [38] Smartphone-based digital colorimetric measurement of dimethyl sulfide in wastewater
    Santiago, Jamila B.
    Sevilla, Fortunato B., III
    MICROCHEMICAL JOURNAL, 2022, 172
  • [39] Validation of diagnostic accuracy of a handheld, smartphone-based rhythm recording device
    Nordin, Astrid Paul
    Carnlof, Carina
    Insulander, Per
    Ali, Amina Mohammad
    Jensen-Urstad, Mats
    Saluveer, Ott
    Drca, Nikola
    EXPERT REVIEW OF MEDICAL DEVICES, 2023, 20 (01) : 55 - 61
  • [40] Accuracy of a Smartphone-based Autorefractor Compared with Criterion-standard Refraction
    Jeganathan, V. Swetha E.
    Valikodath, Nita
    Niziol, Leslie M.
    Hansen, Sean
    Apostolou, Hannah
    Woodward, Maria A.
    OPTOMETRY AND VISION SCIENCE, 2018, 95 (12) : 1135 - 1141