Non-contact Temperature Measurement of Micro-heaters with Two-color Method Using a Single Photon Detector

被引:0
|
作者
Zhang, Wenyi [1 ]
Zhang, Enbo [1 ]
Bain, James A. [1 ]
机构
[1] Carnegie Mellon Univ, ECE Dept, Pittsburgh, PA 15213 USA
关键词
Temperature measurement; HAMR; thermal radiation; two-color pyrometry;
D O I
10.1109/TMRC62973.2024.10713989
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We present a contactless measurement method to characterize the temperature of on-chip micro-heaters through thermal radiation detection. These micro-heaters have widths ranging from 1 to 5 mu m and lengths ranging from 10 to 15 mu m. The temperature is determined by the thermal radiation power ratio within two different wavelength bands, known as the two-color method. A single photon detector (SPD) is employed to enhance the capability of detecting sub-pW radiation signals. This method can accurately measure the temperature of tungsten heaters as low as 700 K. Initial attempts to use this method to measure realistically sized HAMR NFTs temperature have not yet been successful due the signal to background limitations. We present measurements on optically heated NFTs that quantify the required radiation collection efficiency and scattered pump light suppression at the detector that would be necessary to achieve a sufficient signal-to-noise ratio (SNR) to allow NFT temperature measurement using this method.
引用
收藏
页数:2
相关论文
共 50 条
  • [21] Modeling of non-contact temperature measurement system using multiwavelength pyrometry
    Mazikowski, A
    Hypszer, R
    Jedrzejewska-Szczerska, M
    OPTOELECTRONIC AND ELCTRONIC SENSORS IV, 2001, 4516 : 120 - +
  • [22] Temperature Measurement of Photovoltaic Modules Using Non-Contact Infrared System
    Jovanovic, Ugljesa
    Mancic, Dragan
    Jovanovic, Igor
    Petrusic, Zoran
    JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, 2017, 12 (02) : 904 - 910
  • [23] Non-contact respiration rate measurement using a single thermal camera
    Hwang, Hyeonsang
    Lee, Eui Chul
    BASIC & CLINICAL PHARMACOLOGY & TOXICOLOGY, 2018, 124 : 8 - 8
  • [24] Temperature measurement by two-color LIF technique using Nd:YAG lasers
    Y. Watanabe
    Y. Hashizume
    N. Fujisawa
    Journal of Visualization, 2007, 10 : 343 - 344
  • [25] Temperature measurement by two-color LIF technique using Nd:YAG lasers
    Watanabe, Y.
    Hashizume, Y.
    Fujisawa, N.
    JOURNAL OF VISUALIZATION, 2007, 10 (04) : 343 - 344
  • [26] Non-contact temperature measurement method for dynamic rating of overhead power lines
    Lecuna, Ramon
    Castro, Pablo
    Manana, Mario
    Laso, Alberto
    Domingo, Rodrigo
    Arroyo, Alberto
    Martinez, Raquel
    ELECTRIC POWER SYSTEMS RESEARCH, 2020, 185
  • [27] The method of non-contact measurement temperature in the process of high frequency induction heating
    Sun, WL
    Wang, ZH
    Yi, JG
    ICEMI'99: FOURTH INTERNATIONAL CONFERENCE ON ELECTRONIC MEASUREMENT & INSTRUMENTS, VOLS 1 AND 2, CONFERENCE PROCEEDINGS, 1999, : 119 - 122
  • [28] Non-contact measurement of surface flow velocity using photoelectric method
    Wu, Jun
    Ding, Shen-Qi
    Yu, Kui
    Li, Xiao-Biao
    Guangxue Jingmi Gongcheng/Optics and Precision Engineering, 2010, 18 (02): : 349 - 356
  • [29] Two-color Method for Steel Temperature Measurement Unaffected by Water-induced Obstructions
    Sugiura, Masato
    Morioka, Kohsuke
    Tsuchiya, Masaki
    Takaya, Shin
    Tanaka, Ryuji
    Chikita, Daiki
    Sunaga, Kaho
    ISIJ INTERNATIONAL, 2023, 63 (02) : 346 - 353
  • [30] Non-Contact Oxygen Saturation Measurement Using YCgCr Color Space with an RGB Camera
    Kim, Na Hye
    Yu, Su-Gyeong
    Kim, So-Eui
    Lee, Eui Chul
    SENSORS, 2021, 21 (18)