Opportunistic Bone Mineral Density Measurement Using Photon-Counting Detector CT Spectral Localizer Images: A Prospective Study

被引:0
|
作者
El Sadaney, Ahmed O. [1 ]
Ferrero, Andrea [1 ]
Rajendran, Kishore [1 ]
Jasper, Soren [1 ]
Mazza, Gina L. [2 ]
Broski, Stephen M. [1 ]
Shanblatt, Elisabeth [3 ]
Nowak, Tristan [3 ]
Fletcher, Joel G. [1 ]
Mccollough, Cynthia H. [1 ]
Baffour, Francis I. [1 ]
机构
[1] Mayo Clin, Dept Radiol, 2001st St SW, Rochester, MN 55905 USA
[2] Mayo Clin, Dept Quantitat Hlth Sci, Div Clin Trials & Biostat, Scottsdale, AZ USA
[3] Siemens Healthineers, Malvern, PA USA
关键词
bone mineral density; opportunistic imaging; photon-counting detector CT; spectral; localizer;
D O I
10.2214/AJR.24.31909
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BACKGROUND. Spectral localizer images from photon-counting detector (PCD) CT can be used for bone mineral density (BMD) evaluation given their 2D projectional nature and material decomposition capability. As all CTexaminations include localizer images, this approach could allow opportunistic osteoporosis screening of patients undergoing clinically indicated imaging with PCD CT. OBJECTIVE. The purpose of this study was to assess the use of PCD CT spectral localizer images for opportunistic derivation of areal BMD (aBMD) values and T-scores, with dual-energy x-ray absorptiometry (DEXA) used as the reference standard. METHODS. This prospective study included patients 18 years old or older who were scheduled for a clinically indicated lumbar spine CT examination between October 2023 and February 2024 and who underwent DEXA within the previous 13 months or were scheduled for DEXA within the subsequent 13 months. Participants underwent lumbar spine CT by PCD CT including spectral localizer images. The lumbar spine aBMD was extracted from clinical DEXA reports. ROIs were placed on lumbar vertebral bodies and background soft tissues to extract areal densities from spectral localizer images using material decomposition; areal densities were used to derive lumbar spine aBMD values. The aBMD values were used to derive T-scores, which were classified as representing normal (>= -1.0) orabnormal (< -1.0) bone mass. DEXA-derived and PCD CT-derived measurements were compared. RESULTS. The study included 51 participants (31 women and 20 men; mean age, 62 years [range, 28-83 years]). The mean DEXA-derived T-score was 0.4 +/- 1.6 [SD], and the mean PCD CT-derived T-score was 0.3 +/- 1.8 [SD] (p = .29). The Lin concordance correlation coefficient between DEXA-derived and PCD CT-derived T-scores was 0.90. The difference between DEXA-derived and PCD CT-derived T-scores showed a small correlation with patient age (r=-0.13), absolute interval between DEXA and PCD CT (r = 0.15), and BMI (r = 0.28); this difference in scores did not show a significant difference between men and women (0.08 vs 0.13, respectively; p = .81). PCD CT-derived T-scores had a sensitivity of 97%, specificity of 71%, PPV of 90%, and NPV of 91% for detecting abnormal bone mass, with DEXA-derived T-scores used as the reference standard. CONCLUSION. PCD CT spectral localizer images showed clinical utility in deriving aBMD values and, consequently, T-scores.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Quantification of breast density with spectral mammography based on a scanned multi-slit photon-counting detector: a feasibility study
    Ding, Huanjun
    Molloi, Sabee
    PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (15): : 4719 - 4738
  • [32] Editorial Comment: Another Chance to Think Opportunistically Using Photon-Counting Detector CT
    Roth, Trenton D.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2025, 224 (01)
  • [33] A comparative study on the utility and choice parameters of photon-counting CT for bone quantification
    McCabe, Cindy
    Bache, Steve
    Shi, Gengxin
    Breighner, Ryan
    Zbijewski, Wojciech
    Samei, Ehsan
    Abadi, Ehsan
    MEDICAL IMAGING 2024: PHYSICS OF MEDICAL IMAGING, PT 1, 2024, 12925
  • [34] Delineation of the brachial plexus by contrast-enhanced photon-counting detector CT and virtual monoenergetic images
    Nakashima, Masahiro
    Kawai, Tatsuya
    Matsumoto, Kazuhisa
    Kawaguchi, Takatsune
    Kitera, Nobuo
    Watanabe, Seita
    Itoh, Toshihide
    Hiwatashi, Akio
    EUROPEAN JOURNAL OF RADIOLOGY, 2025, 184
  • [35] Spectral metal artifact reduction after posterior spinal fixation in photon-counting detector CT datasets
    Popp, Daniel
    Sinzinger, Andrea X.
    Decker, Josua A.
    Braun, Franziska
    Bette, Stefanie
    Risch, Franka
    Haerting, Mark
    Garthe, Tarik
    Scheurig-Muenkler, Christian
    Kroencke, Thomas J.
    Schwarz, Florian
    EUROPEAN JOURNAL OF RADIOLOGY, 2023, 165
  • [36] Accuracy of bone mineral density quantification using dual-layer spectral detector CT: a phantom study
    van Hamersvelt, Robbert W.
    Schilham, Arnold M. R.
    Engelke, Klaus
    den Harder, Annemarie M.
    de Keizer, Bart
    Verhaar, Harald J.
    Leiner, Tim
    de Jong, Pim A.
    Willemink, Martin J.
    EUROPEAN RADIOLOGY, 2017, 27 (10) : 4351 - 4359
  • [37] Accuracy of bone mineral density quantification using dual-layer spectral detector CT: a phantom study
    Robbert W. van Hamersvelt
    Arnold M. R. Schilham
    Klaus Engelke
    Annemarie M. den Harder
    Bart de Keizer
    Harald J. Verhaar
    Tim Leiner
    Pim A. de Jong
    Martin J. Willemink
    European Radiology, 2017, 27 : 4351 - 4359
  • [38] Infrapopliteal Segments on Lower Extremity CTA: Prospective Intraindividual Comparison of Energy-Integrating Detector CT and Photon-Counting Detector CT
    Yalon, Mariana
    Inoue, Akitoshi
    Thorne, Jamison E.
    Lee, Yong S.
    Johnson, Matthew P.
    Esquivel, Andrea
    Leng, Shuai
    McCollough, Cynthia H.
    Fletcher, Joel G.
    Rajiah, Prabhakar Shantha
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2024, 222 (03)
  • [39] A Universal Protocol for Abdominal CT Examinations Performed on a Photon-Counting Detector CT System A Feasibility Study
    Zhou, Wei
    Michalak, Gregory J.
    Weaver, Jayse M.
    Gong, Hao
    Yu, Lifeng
    McCollough, Cynthia H.
    Leng, Shuai
    INVESTIGATIVE RADIOLOGY, 2020, 55 (04) : 226 - 232
  • [40] Measurement of enhanced vasa vasorum density in a porcine carotid model using photon counting detector CT
    Marsh, Jeffrey F.
    Vercnocke, Andrew J.
    Rajendran, Kishore
    Tao, Shengzhen
    Anderson, Jill L.
    Ritman, Erik L.
    Leng, Shuai
    McCollough, Cynthia H.
    JOURNAL OF MEDICAL IMAGING, 2023, 10 (01)