Unbiased Euclidean Direction Search Algorithm for Partial Discharge Location in Cable Systems

被引:0
|
作者
Wang, Jie [1 ]
Lu, Lu [1 ]
Zhu, Guangya [2 ]
Yin, Kai-Li [3 ]
Zhou, Kai [2 ]
Chen, Badong [4 ]
机构
[1] Sichuan Univ, Coll Elect & Informat Engn, Chengdu 610065, Peoples R China
[2] Sichuan Univ, Coll Elect Engn, High Voltage Lab, Chengdu 610065, Peoples R China
[3] Qingdao Univ Sci & Technol, Coll Automat & Elect Engn, Qingdao 266520, Peoples R China
[4] Xi An Jiao Tong Univ, Inst Artificial Intelligence & Robot IAIR, Xian 710049, Peoples R China
基金
中国国家自然科学基金;
关键词
Noise measurement; Signal processing algorithms; Noise; Power cables; Cable insulation; Accuracy; Estimation; Cable shielding; Vectors; Transient analysis; Cable systems; location; normalized Euclidean direction search (EDS); partial discharge (PD); transient behavior; TOTAL LEAST-SQUARES; LOCALIZATION; KERNEL;
D O I
10.1109/TIM.2025.3538076
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Utilizing the unbiasedness criterion, this article proposes a bias-compensated normalized Euclidean direction search (BC-NEDS) algorithm with noisy inputs, which can effectively mitigate the impact of the bias by estimating the statistical properties of inputs. Moreover, the theoretical analysis of the BC-NEDS algorithm is conducted in a transient regime. Simulations verify the validity of the theoretical analysis and showcase the improved performance of the BC-NEDS algorithm. Partial discharge (PD) location techniques can be utilized to effectively monitor the condition of the electrical apparatus. Considering the performance of the conventional location algorithms based on the time difference of arrival (TDOA) method may notably degrade with noisy inputs. Hitherto, scarce literature concentrates on the PD location problem by leveraging adaptive filtering techniques. Such problem is essentially characterized by a noisy input model. This work aims to propose a new one-step algorithm to simultaneously denoise and achieve improved location accuracy with noisy input. The BC-NEDS algorithm is employed for solving the PD location problem. The BC-NEDS algorithm demonstrates the effectiveness in mitigating the bias arising from noisy inputs in both the direct and reflected PD signals and estimating the time difference to locate the PD signal of cable systems. Simulations and experimental studies exhibit that the BC-NEDS algorithm verifies the effectiveness and achieves enhanced location accuracy for cable systems.
引用
收藏
页数:13
相关论文
共 50 条
  • [11] Partial Discharge Detection and Defect Location Method in GIS Cable Terminal
    Li, Songyuan
    Song, Pengxian
    Wei, Zhanpeng
    Li, Xu
    Tang, Qinghua
    Meng, Zhengzheng
    Li, Ji
    Liu, Songtao
    Wang, Yuhuai
    Li, Jin
    ENERGIES, 2023, 16 (01)
  • [12] Error Analysis of Location Algorithm for Partial Discharge in Substation
    Hou Hui-juan
    Sheng Ge-hao
    Jiang Xiu-chen
    Guan Hong
    Shao Yu-ying
    PROCEEDINGS OF 2012 IEEE INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS (IEEE CMD 2012), 2012, : 782 - 785
  • [13] An algorithm for partial discharge location in distribution power transformers
    Wang, ZD
    Crossley, PA
    Cornick, KJ
    Zhu, DH
    2000 IEEE POWER ENGINEERING SOCIETY WINTER MEETING - VOLS 1-4, CONFERENCE PROCEEDINGS, 2000, : 2217 - 2222
  • [14] FAST EUCLIDEAN DIRECTION SEARCH ALGORITHM IN ADAPTIVE NOISE CANCELLATION AND SYSTEM IDENTIFICATION
    Hosseini, Seyed Abolfazl
    Hadei, Sayed Aref
    Menhaj, Mohammad Bagher
    Azmi, Paeiz
    INTERNATIONAL JOURNAL OF INNOVATIVE COMPUTING INFORMATION AND CONTROL, 2013, 9 (01): : 191 - 206
  • [15] Performance Evaluation of the Fast Euclidean Direction Search Algorithm for Adaptive Beamforming Applications
    Jamel, Thamer M.
    2016 AL-SADIQ INTERNATIONAL CONFERENCE ON MULTIDISCIPLINARY IN IT AND COMMUNICATION TECHNIQUES SCIENCE AND APPLICATIONS (AIC-MITCSA), 2016,
  • [16] Partial Discharge localization on cross-bonded cable systems
    Mahdipour, Mahdi
    Akbari, Asghar
    Werle, Peter
    Borsi, Hossein
    ELECTRIC POWER SYSTEMS RESEARCH, 2020, 178
  • [17] A new approach to partial discharge testing of HV cable systems
    Montanari, GC
    Cavallini, A
    Pulettli, F
    IEEE ELECTRICAL INSULATION MAGAZINE, 2006, 22 (01) : 14 - 23
  • [18] Euclidean direction search algorithm with maximum correntropy criterion for active noise control system
    Wang, Jie
    Lu, Lu
    Zheng, Zongsheng
    Yin, Kai-Li
    Yu, Yi
    Shi, Long
    SIGNAL PROCESSING, 2025, 229
  • [19] Transformer Partial Discharge Location by Optimized Ultrasonic Propagation Path Search
    Shi, Guang-Yu
    Wang, Kang
    Wang, Guo-Bin
    Xu, Xiao-Lin
    2024 THE 7TH INTERNATIONAL CONFERENCE ON ENERGY, ELECTRICAL AND POWER ENGINEERING, CEEPE 2024, 2024, : 121 - 125
  • [20] Multi-end Partial Discharge Location Algorithm based on Trimmed Mean Data Filtering Technique for MV Underground Cable
    Yii, C. C.
    Rohani, M. N. K. H.
    Isa, M.
    Hassan, S. I. S.
    Ismail, B.
    Hussin, N.
    2015 IEEE STUDENT CONFERENCE ON RESEARCH AND DEVELOPMENT (SCORED), 2015, : 345 - 350