Integrated 3D-Printed Hollow Microneedle Array and Lateral Flow Immunoassay for Point-of-Care Wound Healing Monitoring

被引:0
|
作者
Sena-Torralba, Amadeo [1 ]
Parrilla, Marc [2 ,3 ]
Hernanz-Grimalt, Ana [1 ]
Steijlen, Annemarijn [2 ,3 ]
Ortiz-Zapater, Elena [4 ,5 ]
Cabaleiro-Otero, Cristina [6 ]
Lopez-Riquelme, Natividad [6 ]
Cervero-Ferragut, Salvador [6 ]
Maquieira, Angel [1 ,7 ]
De Wael, Karolien [2 ,3 ]
Morais, Sergi [1 ,7 ]
机构
[1] Univ Valencia, Univ Politecn Valencia, Inst Interuniv Invest Reconocimiento Mol & Desarr, Camino Vera S-N, Valencia 46022, Spain
[2] Univ Antwerp, A Sense Lab, B-2020 Antwerp, Belgium
[3] Univ Antwerp, NANOlab Ctr Excellence, B-2010 Antwerp, Belgium
[4] Univ Valencia, Dept Biochem & Mol Biol, Valencia 46010, Spain
[5] Inst Invest Hosp Clin INCLIVA, Valencia 46010, Spain
[6] Hosp Gen Univ Elche, Elche 03203, Alicante, Spain
[7] Univ Politecn Valencia, Dept Quim, Valencia 46022, Spain
基金
荷兰研究理事会;
关键词
PERIODONTAL-DISEASE; BIOMARKERS; MMP-8;
D O I
10.1021/acs.analchem.4c05688
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Chronic wound management requires continuous monitoring to assess healing and guide treatment. We developed a hollow microneedle array patch integrated with a lateral flow immunoassay strip to address the need for convenient, home-based diagnostics. This device extracts wound exudate directly from the wound matrix, overcoming the limitations of conventional swab sampling, which relies on surface exudate collection. The patch provides a minimally invasive, rapid solution to assess the wound healing phase. The immunoassay delivers a colorimetric signal visible to the naked eye, facilitating straightforward interpretation by clinicians within 10 min. In a clinical study involving 90 patients, matrix metalloproteinase 8 (MMP-8) was identified as a critical biomarker, achieving 80.3% sensitivity in detecting the proliferative phase. A specific lateral flow immunoassay for MMP-8 was developed with a detection limit of 0.7 ng/mL, lower than the threshold level for the proliferative healing phase (164.7 ng/mL). The hollow microneedle array patch was 3D-printed for cost-efficiency (less than <euro>0.10 per patch) with a height of 865 +/- 6 mu m, allowing for a painless, easy sampling. Mechanical tests confirmed the durability of the patch, while cytotoxicity assays demonstrated its biocompatibility. Prevalidation using an ex vivo skin model showed the patch could extract 61 +/- 6 mu L of exudate, with a 122% recovery rate for MMP-8 detection, highlighting its efficiency in biomarker extraction. This approach represents a significant advance in decentralized wound care, offering a low-cost, user-friendly tool for at-home monitoring of chronic wounds, potentially improving early intervention and reducing hospital visits.
引用
收藏
页码:20684 / 20692
页数:9
相关论文
共 50 条
  • [21] Development of a smartphone integrated 3D-printed point of care platform for sensitive detection of bilirubin
    Nath, Prathul
    Dey, Ankan
    Kundu, Tathagata
    Chatterjee, Manisha
    Roy, Partha
    Liu, Zhiyi
    Satapathi, Soumitra
    TALANTA, 2025, 286
  • [22] 3D-printed microfluidic manipulation device integrated with magnetic array
    Jie Wu
    Yiwen Cui
    Shouhu Xuan
    Xinglong Gong
    Microfluidics and Nanofluidics, 2018, 22
  • [23] Development and Bioequivalence of 3D-Printed Medication at the Point-of-Care: Bridging the Gap Toward Personalized Medicine
    Lyousoufi, Maryam
    Lafeber, Iris
    Kweekel, Dinemarie
    de Winter, Brenda C. M.
    Swen, Jesse J. J.
    Le Brun, Paul P. H.
    Bijleveld-Olierook, Erica C. M.
    van Gelder, Teun
    Guchelaar, Henk-Jan
    Moes, Dirk Jan A. R.
    Schimmel, Kirsten J. M.
    CLINICAL PHARMACOLOGY & THERAPEUTICS, 2023, 113 (05) : 1125 - 1131
  • [24] 3D-printed microfluidic manipulation device integrated with magnetic array
    Wu, Jie
    Cui, Yiwen
    Xuan, Shouhu
    Gong, Xinglong
    MICROFLUIDICS AND NANOFLUIDICS, 2018, 22 (09)
  • [25] Characteristics of a rapid, point-of-care lateral flow immunoassay for the diagnosis of sickle cell disease
    McGann, Patrick T.
    Schaefer, Beverly A.
    Paniagua, Mary
    Howard, Thad A.
    Ware, Russell E.
    AMERICAN JOURNAL OF HEMATOLOGY, 2016, 91 (02) : 205 - 210
  • [26] DEVELOPMENT AND EVALUATION OF A QUANTITATIVE LATERAL FLOW IMMUNOASSAY FOR THE DETECTION OF FERRITIN AS POINT-OF-CARE TESTING
    Kimura, Fumiaki
    Miyoshi, Sanami
    Mishima, Yasuo
    Shigeto, Nobuyuki
    Fukuda, Tomoko
    Yamahara, Shigehiro
    Matsumura, Tadashi
    Fujii, Shinji
    Tanimoto, Mitsune
    AMERICAN JOURNAL OF HEMATOLOGY, 2013, 88 (05) : E173 - E173
  • [27] Upconversion nanoparticles-based lateral flow immunoassay for point-of-care diagnosis of periodontitis
    He, Wanghong
    You, Minli
    Li, Zedong
    Cao, Lei
    Xu, Feng
    Li, Fei
    Li, Ang
    SENSORS AND ACTUATORS B-CHEMICAL, 2021, 334
  • [28] Ratiometric Fluorescent Lateral Flow Immunoassay for Point-of-Care Testing of Acute Myocardial Infarction
    Wang, Jing
    Jiang, Chenxing
    Jin, Jiening
    Huang, Liang
    Yu, Wenbo
    Su, Bin
    Hu, Jun
    ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2021, 60 (23) : 13042 - 13049
  • [29] Point-of-Care 3-D Printed Spectrophotometer for Therapeutic Drug Monitoring in Tuberculosis Patients
    Hooda, Pragya
    Sami, Muhammad A.
    Hassan, Umer
    IEEE SENSORS LETTERS, 2021, 5 (09)
  • [30] An Integrated Approach to Control the Penetration Depth of 3D-Printed Hollow Microneedles
    Defelippi, Kendall Marie
    Kwong, Allyson Yuuka Saumei
    Appleget, Julia Rose
    Altay, Rana
    Matheny, Maya Bree
    Dubus, Mary Margaret
    Eribes, Lily Marie
    Mobed-Miremadi, Maryam
    APPLIED MECHANICS, 2024, 5 (02): : 233 - 259