Interval cancer in the Cordoba Breast Tomosynthesis Screening Trial (CBTST): comparison of digital breast tomosynthesis plus digital mammography to digital mammography alone

被引:0
|
作者
Pulido-Carmona, Cristina [1 ,2 ,3 ]
Romero-Martin, Sara [1 ,2 ,3 ]
Raya-Povedano, Jose Luis [1 ,2 ,3 ]
Cara-Garcia, Maria [1 ,2 ,3 ]
Font-Ugalde, Pilar [1 ,3 ,4 ]
Elias-Cabot, Esperanza [1 ,2 ,3 ]
Pedrosa-Garriguet, Margarita [1 ,2 ,3 ]
Alvarez-Benito, Marina [1 ,2 ,3 ]
机构
[1] Maimonides Biomed Res Inst Cordoba IMIBIC, Cordoba, Spain
[2] Reina Sofia Univ Hosp, Dept Diagnost Radiol, Breast Canc Unit, Ave Menendez Pidal S-N, Cordoba 14004, Spain
[3] Univ Cordoba, Cordoba, Spain
[4] Reina Sofia Univ Hosp, Dept Rheumatol, Ave Menendez Pidal S-N, Cordoba 14004, Spain
关键词
Breast neoplasms; Digital breast tomosynthesis; Mammography; Mass screening;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeThis work aims to compare the interval cancer rate and interval cancer characteristics between women screened with digital breast tomosynthesis (DBT)+digital mammography (DM) and those screened with DM alone.MethodsThe interval cancer rate and interval cancer characteristics of the study population included in the Cordoba Breast Tomosynthesis Screening Trial (CBTST) were compared to a contemporary control population screened with DM. The tumour characteristics of screen-detected and interval cancers were also compared. Contingency tables were used to compare interval cancer rates. The chi-square test and Fisher's exact test were used to compare the qualitative characteristics of the cancers whereas Student's t test and the Mann-Whitney U test were used to analyse quantitative features.ResultsA total of 16,068 screening exams with DBT+DM were conducted within the CBTST (mean age 57.595.9 [SD]) between January 2015 and December 2016 (study population). In parallel, 23,787 women (mean age 58.895.9 standard deviation [SD]) were screened with DM (control population). The interval cancer rate was lower in the study population than in the control population (15 [0.93; 95% confidence interval (CI): 0.73, 1.14] vs 43 [1.8; 95% CI: 1.58, 2.04] respectively; p=0.045). The difference in rate was more marked in women with dense breasts (0.95 in the study population vs 3.17 parts per thousand in the control population; p=0.031). Interval cancers were smaller in the study population than in the control population (p=0.031).ConclusionsThe interval cancer rate was lower in women screened with DBT+DM compared to those screened with DM alone. These differences were more pronounced in women with dense breasts.
引用
收藏
页码:5427 / 5438
页数:12
相关论文
共 50 条
  • [41] Comparison of digital mammography and digital breast tomosynthesis in the detection of architectural distortion
    Elizabeth H. Dibble
    Ana P. Lourenco
    Grayson L. Baird
    Robert C. Ward
    A. Stanley Maynard
    Martha B. Mainiero
    European Radiology, 2018, 28 : 3 - 10
  • [42] Breast tomosynthesis and digital mammography: a comparison of diagnostic accuracy
    Svahn, T. M.
    Chakraborty, D. P.
    Ikeda, D.
    Zackrisson, S.
    Do, Y.
    Mattsson, S.
    Andersson, I.
    BRITISH JOURNAL OF RADIOLOGY, 2012, 85 (1019): : E1074 - E1082
  • [43] MAMMA - Breast cancer screening: Mammography vs. digital breast tomosynthesis
    Graewert, Stephanie
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2024, 196 (02):
  • [44] Breast Cancer Screening Using Digital Breast Tomosynthesis Not All Mammography Is Equal
    Bahl, Manisha
    Lehman, Constance D.
    JAMA ONCOLOGY, 2019, 5 (05) : 642 - 643
  • [45] Comparison of digital mammography and digital breast tomosynthesis in the detection of architectural distortion
    Dibble, Elizabeth H.
    Lourenco, Ana P.
    Baird, Grayson L.
    Ward, Robert C.
    Maynard, A. Stanley
    Mainiero, Martha B.
    EUROPEAN RADIOLOGY, 2018, 28 (01) : 3 - 10
  • [46] Breast cancer screening in women with and without implants: retrospective study comparing digital mammography to digital mammography combined with digital breast tomosynthesis
    Ethan O. Cohen
    Rachel E. Perry
    Hilda H. Tso
    Kanchan A. Phalak
    Michele D. Lesslie
    Karen E. Gerlach
    Jia Sun
    Ashmitha Srinivasan
    Jessica W. T. Leung
    European Radiology, 2021, 31 : 9499 - 9510
  • [47] Digital Breast Tomosynthesis Plus Ultrasound Versus Digital Mammography Plus Ultrasound for Screening Breast Cancer in Women With Dense Breasts
    Ha, Su Min
    Yi, Ann
    Yim, Dahae
    Jang, Myoung-jin
    Kwon, Bo Ra
    Shin, Sung Ui
    Lee, Eun Jae
    Lee, Soo Hyun
    Moon, Woo Kyung
    Chang, Jung Min
    KOREAN JOURNAL OF RADIOLOGY, 2023, 24 (04) : 274 - 283
  • [48] Breast cancer screening in women with and without implants: retrospective study comparing digital mammography to digital mammography combined with digital breast tomosynthesis
    Cohen, Ethan O.
    Perry, Rachel E.
    Tso, Hilda H.
    Phalak, Kanchan A.
    Lesslie, Michele D.
    Gerlach, Karen E.
    Sun, Jia
    Srinivasan, Ashmitha
    Leung, Jessica W. T.
    EUROPEAN RADIOLOGY, 2021, 31 (12) : 9499 - 9510
  • [49] Digital breast tomosynthesis plus mammography, magnetic resonance imaging plus mammography and mammography alone: A comparison of diagnostic performance in symptomatic women
    Tang, Wei
    Hu, Fei-Xiang
    Zhu, Hui
    Wang, Qi-Feng
    Gu, Ya-Jia
    Peng, Wei-Jun
    CLINICAL HEMORHEOLOGY AND MICROCIRCULATION, 2017, 66 (02) : 105 - 116
  • [50] Addition of Screening Breast US to Digital Mammography and Digital Breast Tomosynthesis for Breast Cancer Screening in Women at Average Risk
    Yi, Ann
    Jang, Myoung-jin
    Yim, Dahae
    Kwon, Bo Ra
    Shin, Sung Ui
    Chang, Jung Min
    RADIOLOGY, 2021, 298 (03) : 568 - 575