Evaluating the liquid egg white freshness: Development, mechanistic analysis and application of a novel electrochemical method-based rapid detection technique

被引:0
|
作者
Yang, Shuo [1 ]
Yang, Fuming [1 ]
Chi, Yuan [2 ]
Chi, Yujie [1 ]
机构
[1] Northeast Agr Univ, Coll Food Sci, Harbin 150030, Peoples R China
[2] Northeast Agr Univ, Coll Engn, Harbin 150030, Peoples R China
关键词
Electrochemical Haugh unit; Liquid egg white freshness; Detection technique; Nonlinear; Logistic; Model validation; Model application; RHEOLOGICAL PROPERTIES; INFRARED-SPECTROSCOPY; HAUGH UNIT; QUALITY;
D O I
10.1016/j.cej.2024.158183
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Globally, liquid eggs are gradually replacing shell eggs as the primary fresh eggs in market, yet no techniques for assessing their freshness. This study aims to establish E-HU (electrochemical Haugh units) models for detecting LEW's (liquid egg white) freshness: a Nonlinear regression model (M-1) for predicting Haugh units, and a Logistic regression model (M-2) for predicting freshness grade. Both models were validated, mechanistically analyzed, and applied. Validation: M-1 passed joint hypothesis test, regression coefficient test, correlation coefficient test (R2: 0.92), and accuracy test (92.9%). M-2 passed categorical hypothesis test (chi 2: 72.8), goodness-of-fit test (PR2: 0.93), and accuracy test (89.1%, for unfresh LEW: 95.2%), indicating E-HU model is reasonable. Mechanistic analysis: FT-IR and particle size demonstrate changes in proteins' structure (side chains, beta-turns, and aggregated beta-sheets increased; intramolecular beta-sheets and random coils decreased). Water activity, contact angle (86.0 degrees- 64.4 degrees to 91.0 degrees-68.3 degrees), surface tension (47.1-45.0 to 54.1-49.9 mN & sdot;m 1 ), LF-NMR (relaxation time T1: 383 to 333 ms; T2: 542-581 to 440-506 ms), and magnetic resonance imaging, indicate changes in hydration capacity. Briefly, proteins' structural changes and water migration during storage alter the LEW's electrochemical properties. Application (10 varieties): M-1 has high accuracy (brown-shelled eggs: 68.4%). M-2 has higher accuracy (total: 80.0%; pink-shelled eggs: 75.0%; brown-shelled eggs: 100%). In summary, a novel non-destructive and rapid detection technology (E-HU) was developed, demonstrating high accuracy in predicting Haugh unit and freshness grade of LEW. This innovation fills a gap in liquid egg detection technology and offers a valuable reference for future research.
引用
收藏
页数:19
相关论文
共 50 条
  • [31] Development of a 6-hydroxychroman-based derivatization reagent: application to the analysis of 5-hydroxytryptamine and catecholamines by using high-performance liquid chromatography with electrochemical detection
    Sasaki, Tsukasa
    Fukushima, Takeshi
    Ohishi, Madoka
    Toyo'oka, Toshimasa
    BIOMEDICAL CHROMATOGRAPHY, 2008, 22 (08) : 888 - 899
  • [32] Development and Application of an RPA-Based Rapid Point-of-Care Testing (POCT) Method for the Detection of Feline Panleukopenia Virus
    Hong, Liang
    Huang, Qian
    Zhou, Yuhang
    Zheng, Qi
    Wang, Shipeng
    Chen, Fangfang
    Chang, Xinyue
    Jiang, Guosheng
    Zha, Lisha
    TRANSBOUNDARY AND EMERGING DISEASES, 2024, 2024
  • [33] Development of Novel and Highly Specific ssDNA-Aptamer-Based Electrochemical Biosensor for Rapid Detection of Mercury (II) and Lead (II) Ions in Water
    Abu-Ali, Hisham
    Nabok, Alexei
    Smith, Thomas J.
    CHEMOSENSORS, 2019, 7 (02)
  • [34] Development of a novel liquid chromatography-tandem mass spectrometric method for aristolochic acids detection: Application in food and agricultural soil analyses
    Chan, Chi-Kong
    Pavlovic, Nikola M.
    Chan, Wan
    FOOD CHEMISTRY, 2019, 289 : 673 - 679
  • [35] A rapid and recyclable analysis method for sulfadimethoxine detection based on molecularly imprinted electrochemical sensor reinforced by GQDs/ZIF-8 nanocomposite
    Hatamluyi, Behnaz
    Sadeghzadeh, Samira
    Zehi, Zakiyeh Balouch
    Rezayi, Majid
    Sany, Seyedeh Belin Tavakoly
    MICROCHEMICAL JOURNAL, 2023, 185
  • [36] A novel defect detection method with eliminating dust for specular surfaces based on structured-light modulation analysis technique
    Huang, Yiyang
    Wang, Jie
    Song, Yiping
    Yue, Huimin
    Fang, Yuyao
    Liu, Yong
    OPTICS AND LASER TECHNOLOGY, 2021, 141
  • [37] Rapid, Sensitive, and Validated HPLC Method for Analysis of Metronidazole and Tinidazole under Identical Chromatographic Conditions with UV Detection and Liquid-Liquid Extraction: Application in Bioequivalence Studies
    Emami, J.
    Rezazadeh, M.
    ACTA CHROMATOGRAPHICA, 2013, 25 (01) : 111 - 125
  • [38] Development of a Novel Lateral Flow Biosensor Combined With Aptamer-Based Isolation: Application for Rapid Detection of Grouper Nervous Necrosis Virus
    Liu, Jiaxin
    Qin, Qiwei
    Zhang, Xinyue
    Li, Chen
    Yu, Yepin
    Huang, Xiaohong
    Mukama, Omar
    Zeng, Lingwen
    Wang, Shaowen
    FRONTIERS IN MICROBIOLOGY, 2020, 11
  • [39] Development of Head Space Method Based on Rapid Vapor-Liquid Equilibrium with Ink-Jet and Its Application to On-Line Analysis for Volatile Organic Compounds in Water
    Seino, Nobuko
    Kaneko, Yuji
    Nakajima, Hizuru
    Uchiyama, Katsumi
    BUNSEKI KAGAKU, 2010, 59 (07) : 619 - 625
  • [40] DEVELOPMENT OF A SIMPLE ANALYTICAL METHOD TO DETERMINE THE SERUM CONCENTRATION OF DENOPAMINE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH ELECTROCHEMICAL DETECTION AND ITS CLINICAL-APPLICATION
    MORIKAWA, N
    HIGUCHI, K
    TSUKAMOTO, T
    NAKANO, M
    TERADA, H
    YAKUGAKU ZASSHI-JOURNAL OF THE PHARMACEUTICAL SOCIETY OF JAPAN, 1989, 109 (11): : 858 - 864