Type of D-dimer assay determines the diagnostic yield of computed tomography in patients suspected for pulmonary embolism

被引:0
|
作者
Assmann, Jorn L. J. C. [1 ]
Gammeren, Adriaan J. van [2 ]
Sprenger, Reinier A. [3 ]
de Wit, Saskia [4 ]
Ceelie, Huib [5 ]
Leebeek, Frank W. G. [6 ]
Schellings, Mark W. M. [1 ]
机构
[1] Maasstad Hosp, Clin Chem, MaasstadLab, Maasstadweg 21, NL-3079 DZ Rotterdam, Netherlands
[2] Amphia Hosp, Dept Clin Chem & Hematol, Breda, Netherlands
[3] Maasstad Hosp, Dept Internal Med, Rotterdam, Netherlands
[4] Amphia Hosp, Dept Business Intelligence, Breda, Netherlands
[5] Franciscus Gasthuis & Vlietland, Dept Clin Chem, Rotterdam, Netherlands
[6] Erasmus MC, Dept Hematol, Rotterdam, Netherlands
关键词
D-dimer; computed tomography; pulmonary embolism; Wells; YEARS; RULE; ANGIOGRAPHY; MANAGEMENT; EXCLUSION;
D O I
10.1016/j.rpth.2024.102638
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Pulmonary embolism (PE) is a life-threatening condition with high morbidity and mortality. The diagnosis of PE is challenging due to nonspecific symptoms, making reliable diagnostic tools essential. This study addresses the clinical impact of interassay variability in D-dimer measurements on the utilization and diagnostic yield of computed tomography pulmonary angiography (CTPA). Objectives: To investigate the effect of different D-dimer assays on the decision to perform CTPA and the subsequent diagnostic yield in patients with suspected PE. Methods: This retrospective, multicenter cohort study analyzed data from 3 teaching hospitals in the southwest region of the Netherlands, covering the years 2018, 2019, 2022, and 2023. The study included data from 40,096 clinically requested D-dimer results and 11,372 CTPA records of patients with suspected PE. The D-dimer assays used were the Roche Tina-quant and Siemens INNOVANCE. Results: The study found significant differences in CTPA utilization and diagnostic yield based on the D-dimer assay used. In 2018 to 2019, hospitals using the Roche Tinaquant assay ordered 21% fewer CTPA scans and had a 9% higher positivity rate compared with those using the Siemens INNOVANCE assay. Conclusion: The findings highlight the necessity for assay-specific cutoff values or, ideally, the standardization of the D-dimer assay to optimize the accuracy and efficiency of PE diagnosis. This study demonstrates that the choice of D-dimer assay significantly influences the clinical management of suspected PE, affecting both the number of CTPA scans performed and the positivity rate of these scans. Implementing assay-specific cutoff values or standardization of the D-dimer assay could reduce unnecessary CTPA scans, minimize patient exposure to radiation, and lower healthcare costs. These results advocate enhanced collaboration between clinicians and laboratory specialists to accurately interpret D-dimer results within the context of the specific assay used. Future research should validate these findings in prospective studies and explore standardized protocols that account for interassay variability.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Inappropriate Use of D-Dimer Assay and Pulmonary CT Angiography in the Evaluation of Suspected Acute Pulmonary Embolism
    Yin, Fang
    Wilson, Thomas
    Della Fave, Albert
    Larsen, Moira
    Yoon, Jenni
    Nugusie, Binyam
    Freeland, Howard
    Chow, Robert Dobbin
    AMERICAN JOURNAL OF MEDICAL QUALITY, 2012, 27 (01) : 74 - 79
  • [42] The place of D-dimer testing in an integrated approach of patients suspected of pulmonary embolism
    de Moerloose, P
    Michiels, JJ
    Bounameaux, H
    SEMINARS IN THROMBOSIS AND HEMOSTASIS, 1998, 24 (04): : 409 - 412
  • [43] D-dimer test for suspected pulmonary embolism in inpatients.
    Cocci, F
    Monti, S
    Bauleo, C
    Prediletto, R
    Pistolesi, M
    Marini, C
    Di Ricco, G
    Formichi, B
    Rizzello, L
    Tonelli, L
    Allescia, G
    Carrozzi, L
    Dainelli, A
    Miniati, M
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1999, 159 (03) : A456 - A456
  • [44] Capnometry in suspected pulmonary embolism with positive D-dimer in the field
    Rumpf, Tadeja Hernja
    Krizmaric, Miljenko
    Grmec, Stefek
    CRITICAL CARE, 2009, 13 (06): : R196
  • [45] Capnometry in suspected pulmonary embolism with positive D-dimer in the field
    Tadeja Hernja Rumpf
    Miljenko Križmarić
    Štefek Grmec
    Critical Care, 13
  • [46] Validation of a new D-dimer microparticle enzyme immunoassay (AxSYM D-Dimer) in patients with suspected pulmonary embolism (PE)
    Ghanima, W.
    Sandset, P. M.
    THROMBOSIS RESEARCH, 2007, 120 (04) : 471 - 476
  • [47] The Increasing Use of D-Dimer Testing in Suspected Pulmonary Embolism
    Hoo, Guy Soo
    Barack, Bruce
    Vazirani, Sondra
    Li, Zhaoping
    Wu, Carol
    CHEST, 2015, 148 (04)
  • [48] Clinical decision support increases diagnostic yield of computed tomography for suspected pulmonary embolism
    Mills, Angela M.
    Ip, Ivan K.
    Langlotz, Curtis P.
    Raja, Ali S.
    Zafar, Hanna M.
    Khorasani, Ramin
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2018, 36 (04): : 540 - 544
  • [49] Prospective study of the diagnostic accuracy of the simplify D-dimer assay for pulmonary embolism in emergency department patients
    Kline, Jeffrey A.
    Runyon, Michael S.
    Webb, William B.
    Jones, Alan E.
    Mitchell, Alice M.
    CHEST, 2006, 129 (06) : 1417 - 1423
  • [50] Concentration of D-DIMER in patients with pulmonary embolism
    Golubovic, M
    MajkicSingh, N
    Vukosavljevic, D
    Maksic, N
    Durdevic, V
    JUGOSLOVENSKA MEDICINSKA BIOHEMIJA-YUGOSLAV MEDICAL BIOCHEMISTRY, 1996, 15 (04): : 302 - 302