Evaluation of a semi-automated test for quantification of von Willebrand multimers

被引:0
|
作者
Peronino, Christophe [1 ]
Rivet, Nadia [1 ,2 ]
Itzhar-Baikian, Nathalie [3 ,4 ]
Philippe, Aurelien [1 ,2 ]
Joly, Berangere S. [3 ,4 ]
Bezieux, Joseph Roux de [1 ]
Luneau, Sophie [1 ,2 ]
Martin, Anne-Celine [1 ,5 ]
Veyradier, Agnes [3 ,4 ]
Gaussem, Pascale [1 ,2 ]
Gendron, Nicolas [1 ,2 ]
Smadja, David M. [1 ,2 ]
机构
[1] Univ Paris Cite, Innovat Therapies Haemostasis, INSERM, UMR S1140, F-75006 Paris, France
[2] Hop Europeen Georges Pompidou, AP HP, Serv Hematol Biol, F-75015 Paris, France
[3] Univ Paris Cite, Hop Lariboisiere, AP HP Nord, Serv hematol Biol, F-75010 Paris, France
[4] Univ Paris Cite, Inst Rech St Louis, EA3518, Paris, France
[5] Hop Europeen Georges Pompidou, AP HP, Serv Chirurg Cardiaque, UMICS, F-75015 Paris, France
关键词
von Willebrand Factor; von Willebrand factor multimers; electrophoresis; Mechanical Circulatory Device; Acquired von Willebrand Syndrome;
D O I
10.1684/abc.2024.1903
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Context: The assessment of von Willebrand factor (VWF) multimer distribution, particularly following the implantation of circulatory support devices, is a crucial parameter in hemostasis. Our study aimed to evaluate the semi-automated quantification of VWF multimers using the Sebia Hydrasys analyzer. Methods: Our analysis focused on quantifying high molecular weight, intermediate weight, and low molecular weight VWF multimers. Electrophoretic migration was performed using the Hydrasys 2 scan, and interpretation was carried out using densitometric analysis with the Phoresis software. Results: The Hydrasys scan 2 successfully separated all the expected VWF multimer profiles based on the type of von Willebrand disease. The analysis revealed that in patients with circulatory support devices, elevated levels of plasma VWF rendered multimer migration unanalyzable using the methodology recommended by the manufacturer. Therefore, adjustment to a 100 % VWF antigenic level improved gel precision. We also suggest using as a standardized control the CryocheckTM plasma, and have established reference values. Conclusion: Overall, this semi-automated, standardized, and optimized VWF multimer analysis system allows for an effective assessment of the VWF multimeric profile.
引用
收藏
页码:361 / 375
页数:15
相关论文
共 50 条
  • [21] Simultaneous and semi-automated evaluation of three variable tandem repeats within von Willebrand factor gene by capillary electrophoresis with multicolour fluorescent detection
    Habart, D
    Vorlová, Z
    ACTA HAEMATOLOGICA, 2003, 110 (01) : 41 - 42
  • [22] An empirical evaluation of RAIDE: A semi-automated approach for test smells detection and refactoring
    Santana, Railana
    Martins, Luana
    Virginio, Tassio
    Rocha, Larissa
    Costa, Heitor
    Machado, Ivan
    SCIENCE OF COMPUTER PROGRAMMING, 2024, 231
  • [23] Observer evaluation of semi-automated mesothelioma measurements
    Armato, S
    Oxnard, G
    Kocherginsky, M
    Vogelzang, N
    Kindler, H
    MacMahon, H
    MEDICAL PHYSICS, 2005, 32 (06) : 2121 - 2121
  • [24] Evaluation of mixed semi-automated/manual traffic
    Bose, A
    Ioannou, P
    PROCEEDINGS OF THE 1998 IEEE INTERNATIONAL CONFERENCE ON CONTROL APPLICATIONS, VOLS 1 AND 2, 1996, : 868 - 872
  • [25] Evaluation of Semi-automated Ontology Instance Migration
    Davidovsky, Maxim
    Ermolayev, Vadim
    Matzke, Wolf-Ekkehard
    Tolok, Vyacheslay
    INTELLIGENT DISTRIBUTED COMPUTING IV, 2010, 315 : 179 - +
  • [26] Semi-automated evaluation tool for retinal vasculopathy
    Benavent, X.
    Martinez-Costa, L.
    Ayala, G.
    Domingo, J.
    Marco, P.
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2009, 95 (03) : 288 - 299
  • [27] Evaluation of semi-automated testing in a transfusion service
    Tretter, C
    Johnson, DO
    Crandall, D
    Domkowski, T
    Redmond, W
    Kaeding, C
    TRANSFUSION, 1999, 39 (10) : 138S - 139S
  • [28] Evaluation of a Semi-Automated Workflow for Fragment Growing
    Pirard, Bernard
    Ertl, Peter
    JOURNAL OF CHEMICAL INFORMATION AND MODELING, 2015, 55 (01) : 180 - 193
  • [29] Evaluation of a Semi-Automated Method for Washing Platelets
    Madrid, Fatima
    Tse, Lok
    TRANSFUSION, 2017, 57 : 83A - 83A
  • [30] EVALUATION OF A SEMI-AUTOMATED ENZYME IMMUNOASSAY FOR DIGOXIN
    PRUNSTER, G
    HILDEBRAND, R
    SAMPSON, DC
    HENSLEY, WJ
    PATHOLOGY, 1978, 10 (04) : 398 - 399