Novel cardiac CT method for identifying the atrioventricular conduction axis by anatomic landmarks

被引:0
|
作者
Tretter, Justin T. [1 ]
Bedogni, Francisco [2 ]
Rodes-Cabau, Josep [3 ]
Regueiro, Ander [4 ]
Testa, Luca [2 ]
Eleid, Mackram F. [5 ]
Chen, Shmuel [6 ]
Galhardo, Attilio [3 ]
Ellenbogen, Kenneth A. [7 ]
Leon, Martin B. [8 ,9 ]
Ben-Haim, Shlomo [1 ]
机构
[1] Hobart Healthcare Res Inst, London, England
[2] Policlin San Donato, Milan, Italy
[3] Laval Univ, Quebec Heart & Lung Inst, Quebec City, PQ, Canada
[4] Hosp Clin Barcelona, Barcelona, Spain
[5] Mayo Clin, Rochester, MN USA
[6] NewYork Presbyterian Weill Cornell, New York, NY USA
[7] Virginia Commonwealth Univ, Sch Med, Richmond, VA USA
[8] Columbia Univ, Irving Med Ctr, NewYork Presbyterian Hosp, New York, NY USA
[9] Cardiovasc Res Fdn, New York, NY USA
关键词
Atrioventricular node; Conduction system; Pacing; Left bundle branch; Transcatheter aortic valve replacement;
D O I
10.1016/j.hrthm.2024.12.022
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND Understanding the conduction axis location aids in avoiding iatrogenic damage and guiding targeted heart rhythm therapy. OBJECTIVE Cardiac structures visible with clinical imaging have been demonstrated to correlate with variability in the conduction system course. We aimed to standardize and assess the reproducibility of predicting the location of the atrioventricular conduction axis by cardiac computed tomography. METHODS We evaluated 477 patients with acquired aortic valve disease by cardiac computed tomography to assess variability in cardiac structures established to relate to the conduction system. We standardized 3 points (points A-C) to estimate the course from the atrioventricular node to the nonbranching bundle and left bundle branch origin and further compared this with measures of variability in the aortic root and membranous septum. RESULTS The mean distances between the aortic valve virtual basal ring and points A, B, and C were 9.5 +/- 3.5 (0.3-20.1) mm, 5.0 +/- 2.6 (-1.7 to 15.9) mm, and 2.9 +/- 2.5 (-5.2 to 12.0) mm, respectively. The midpoint of the membranous septum deviated posteriorly a median of -4.4 (interquartile range, -12.4 to +3.0) degrees relative to the commissure between the right coronary and noncoronary leaflets. Intraclass coefficients for both intraobserver and interobserver variability for all measured points were of the atrioventricular components of the conduction axis, which may serve as a noninvasive means for estimating its location.
引用
收藏
页码:776 / 785
页数:10
相关论文
共 29 条
  • [21] Environmental Fe, Ti, Al, Cu, Hg, Bi, and Si Nanoparticles in the Atrioventricular Conduction Axis and the Associated Ultrastructural Damage in Young Urbanites: Cardiac Arrhythmias Caused by Anthropogenic, Industrial, E-Waste, and Indoor Nanoparticles
    Calderon-Garciduenas, Lilian
    Gonzalez-Maciel, Angelica
    Reynoso-Robles, Rafael
    Luis Rodriguez-Lopez, Jose
    Silva-Pereyra, Hector G.
    Labrada-Delgado, Gladis J.
    Perez-Guille, Beatriz
    Eugenia Soriano-Rosales, Rosa
    Jimenez-Bravo Luna, Miguel Angel
    Brito-Aguilar, Rafael
    Mukherjee, Partha S.
    Gayosso-Chavez, Carlos
    Delgado-Chavez, Ricardo
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2021, 55 (12) : 8203 - 8214
  • [22] A novel method for incorporating respiratory-matched attenuation correction in the motion correction of cardiac PET-CT studies
    McQuaid, Sarah J.
    Lambrou, Tryphon
    Hutton, Brian F.
    PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (10): : 2903 - 2915
  • [23] NOVEL METHOD FOR REAL-TIME CARDIAC CT AND CORONARY ANGIOGRAPHY IMAGE REGISTRATION AS A TOOL FOR PERCUTANEOUS CORONARY INTERVENTION OF CHRONIC TOTAL OCCLUSIONS
    Nomura, Yu
    Oyama, Kazuma
    Shishido, Koki
    Imori, Yoichi
    Osaka, Yumiko
    Yamanaka, Futoshi
    Okamura, Nobuhiro
    Mizuno, Shingo
    Suenaga, Hidetaka
    Murakami, Masato
    Matsumi, Junya
    Takeshita, Satoshi
    Saito, Shigeru
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 59 (13) : E1212 - E1212
  • [24] Novel method for real-time hybrid cardiac CT and coronary angiography image registration: visualising beyond luminology, proof-of-concept
    Roguin, Ariel
    Abadi, Sobhi
    Engel, Ahuva
    Beyar, Rafael
    EUROINTERVENTION, 2009, 4 (05) : 648 - 653
  • [25] CORRELATION OF CARDIO-ANKLE VASCULAR INDEX AND CARDIAC CT ANGIOGRAPHY MARKERS: A NOVEL NON-INVASIVE METHOD TO DETECT SUBCLINICAL ATHEROSCLEROSIS
    Rezaeian, Panteha
    Gavini, Frank
    Razipour, Aryabod
    Dailing, Christopher
    Flores, Ferdinand
    Luo, Yanting
    Budoff, Matthew
    CLINICAL CARDIOLOGY, 2016, 39 : 9 - 9
  • [26] Droplet Digital PCR Is a Novel Screening Method Identifying Potential Cardiac G-Protein-Coupled Receptors as Candidate Pharmacological Targets in a Rat Model of Pressure-Overload-Induced Cardiac Dysfunction
    Sayour, Nabil V.
    Toth, Viktoria E.
    Nagy, Regina N.
    Voros, Imre
    Gergely, Tamas G.
    Onodi, Zsofia
    Nagy, Noemi
    Bodor, Csaba
    Varadi, Barnabas
    Ruppert, Mihaly
    Radovits, Tamas
    Bleckwedel, Federico
    Zelarayan, Laura C.
    Pacher, Pal
    Agg, Bence
    Gorbe, Aniko
    Ferdinandy, Peter
    Varga, Zoltan V.
    INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2023, 24 (18)
  • [27] A novel approach to the selection of an appropriate pacing position for optimal cardiac resynchronization therapy using CT coronary venography and myocardial perfusion imaging: FIVE STaR method (fusion image using CT coronary venography and perfusion SPECT applied for cardiac resynchronization therapy)
    Tada, Tomohiro
    Osuda, Koichi
    Nakata, Tomoaki
    Muranaka, Ippei
    Himeno, Masafumi
    Muratsubaki, Shingo
    Murase, Hiromichi
    Sato, Kenji
    Hirose, Masanori
    Fukuma, Takayuki
    JOURNAL OF NUCLEAR CARDIOLOGY, 2021, 28 (04) : 1438 - 1445
  • [28] A novel approach to the selection of an appropriate pacing position for optimal cardiac resynchronization therapy using CT coronary venography and myocardial perfusion imaging: FIVE STaR method (fusion image using CT coronary venography and perfusion SPECT applied for cardiac resynchronization therapy)
    Tomohiro Tada
    Koichi Osuda
    Tomoaki Nakata
    Ippei Muranaka
    Masafumi Himeno
    Shingo Muratsubaki
    Hiromichi Murase
    Kenji Sato
    Masanori Hirose
    Takayuki Fukuma
    Journal of Nuclear Cardiology, 2021, 28 : 1438 - 1445
  • [29] A novel blind deconvolution method incorporated with anatomical-based filtering for partial volume correction: validations with 123I-mIBG cardiac SPECT/CT imaging
    Wu, Jing
    Liu, Hui
    Mohy-ud-Din, Hassan
    Thorn, Stephanie
    Stacy, Mitchel
    Zonouz, Taraneh Hashemi
    Liu, Chi
    Sinusas, Albert
    Lampert, Rachel
    Liu, Yi-Hwa
    JOURNAL OF NUCLEAR MEDICINE, 2016, 57