2D Localisation Using Magneto-Inductive Waveguides

被引:0
|
作者
Dima, Georgiana [1 ]
Spanos, Ioannis [1 ]
Stevens, Christopher J. [1 ]
机构
[1] Univ Oxford, Dept Engn Sci, Pk Rd, Oxford OX1 3PJ, England
关键词
D O I
10.1109/Metamaterials62190.2024.10703237
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This study investigated a two-dimensional(2D) magneto-inductive waveguide as a sensing device for low-conductivity samples, which mimic the effect of touchscreen interactions. A neural network was trained to predict the 2D location of a sample with conductivity of 0.64 S/m, using spectral components obtained from a single, asymmetrical probing point as features. The model achieved an accuracy of 99% up to 12 mm away from the surface. This research advances the potential implementation of magneto-inductive waveguides in touchscreen arrays and biomedical applications.
引用
收藏
页数:3
相关论文
共 50 条
  • [31] Magneto-Inductive Magnetic Resonance Imaging Duodenoscope
    Syms, Richard R. A.
    Kardoulaki, Evdokia
    Rea, Marc
    Choonee, Kaushal
    Taylor-Robinson, Simon
    Wadsworth, Christopher
    Young, Ian R.
    PROGRESS IN ELECTROMAGNETICS RESEARCH-PIER, 2017, 159 : 125 - 138
  • [32] Magneto-Inductive (MI) navigation in littoral environments
    Wrathall, PN
    Dinn, DF
    Sojdehei, JJ
    INFORMATION SYSTEMS FOR DIVERS AND AUTONOMOUS UNDERWATER VEHICLES OPERATING IN VERY SHALLOW WATER AND SURF ZONE REGIONS II, 2000, 4039 : 104 - 111
  • [33] Underground Incrementally Deployed Magneto-Inductive 3-D Positioning Network
    Abrudan, Traian E.
    Xiao, Zhuoling
    Markham, Andrew
    Trigoni, Niki
    IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 2016, 54 (08): : 4376 - 4391
  • [34] Characterization of a 3D Underwater Magneto-Inductive Transmitter Coil Array
    Ravindran, S. R. Padyath
    Bousquet, J. -F.
    Gaoding, N.
    OCEANS 2018 MTS/IEEE CHARLESTON, 2018,
  • [35] Magneto-Inductive Catheter Receiver for Magnetic Resonance Imaging
    Syms, Richard R. A.
    Young, Ian R.
    Ahmad, Munir M.
    Taylor-Robinson, Simon D.
    Rea, Marc
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2013, 60 (09) : 2421 - 2431
  • [36] Magneto-inductive Passive Relaying in Arbitrarily Arranged Networks
    Dumphart, Gregor
    Slottke, Eric
    Wittneben, Armin
    2017 IEEE INTERNATIONAL CONFERENCE ON COMMUNICATIONS (ICC), 2017,
  • [37] Magneto-Inductive Underground Communications in a District Heating System
    Meybodi, Soroush Afkhami
    Nielsen, Jens
    Bendtsen, Jan
    Dohler, Mischa
    2011 IEEE INTERNATIONAL CONFERENCE ON COMMUNICATIONS (ICC), 2011,
  • [38] Experimental Study of Posture Detection Using Purely Passive Magneto-Inductive Tags
    Schulten, Henry
    Wittneben, Armin
    2022 IEEE WIRELESS COMMUNICATIONS AND NETWORKING CONFERENCE (WCNC), 2022, : 2643 - 2648
  • [39] Magneto-inductive cable arrays: Estimation and reduction of crosstalk
    Syms, R. R. A.
    Solymar, L.
    JOURNAL OF APPLIED PHYSICS, 2011, 109 (04)
  • [40] Effects of Metal Structures on Magneto-Inductive Coupled Coils
    Ahmed, Niaz
    Zheng, Yahong Rosa
    Pommerenke, David
    2016 IEEE THIRD UNDERWATER COMMUNICATIONS AND NETWORKING CONFERENCE (UCOMMS), 2016,