Coronal preflaring's influence on the accuracy of root canal length determination by electronic apex locators

被引:0
|
作者
Batista, Larissa C. Novaes [1 ]
Janini, Ana Cristina Padilha [2 ]
Marciano, Marina A. [2 ]
Guimaraes, Tatiany G. F. Araujo
Guimaraes, Bruno Martini [1 ]
机构
[1] Univ Fed Alfenas, UNIFAL MG, Alfenas, MG, Brazil
[2] Univ Estadual Campinas, Fac Odontol Piracicaba, Piracicaba, Brazil
关键词
Cervical preflaring; Electronic apex locators; Root canal preparation; FORAMEN; DISTANCE; SIZE;
D O I
10.24873/j.rpemd.2024.10.1230
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: To evaluate the influence of preflaring using LA Axxess and ProTaper Shaping files on the accuracy of Root ZX mini, Mini Apex Locator, and Propex II electronic apex locators (EALs). Methods: Thirty mandibular incisors were accessed, and their root canal length (RCL) was determined with the aid of a stereomicroscope. Then, the specimens were randomly assigned into two groups according to the preflaring instrument: G1- LA Axxess; G2- ProTaper Shaping files. The root canal length was determined in the alginate model by EALs before and after preflaring. Data were classified as accurate (<= 0.5 mm) or inaccurate (> 0.5 mm or beyond the root canal length). McNemar's test was used to detect differences in the EALs' accuracy before and after preflaring, and Cochran's Q test was applied to detect differences in accuracy between the EALs. Results: McNemar's test identified differences in precision in the Propex II and Mini Apex Locator, with significantly increased accuracy after preflaring with ProTaper files. Cochrans' Q test showed no differences between EALs' accuracy (p>.05). Conclusions: Preflaring procedures increased accurate measurements for all the EALs, with statistical differences for Propex II and Mini Apex Locator when ProTaper instruments were used. All EALs showed similar accuracy. (Rev Port Estomatol Med Dent Cir Maxilofac. 2023;65(3):115-120) (c) 2024 Sociedade Portuguesa de Estomatologia e Medicina Dentaria. Published by SPEMD. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
引用
收藏
页码:115 / 120
页数:6
相关论文
共 50 条
  • [21] In vivo comparison of working length determination with two electronic apex locators
    Wrbas, K. T.
    Ziegler, A. A.
    Altenburger, M. J.
    Schirrmeister, J. F.
    INTERNATIONAL ENDODONTIC JOURNAL, 2007, 40 (02) : 133 - 138
  • [22] Comparison of working length determination with radiographs and four electronic apex locators
    Vieyra, J. P.
    Acosta, J.
    INTERNATIONAL ENDODONTIC JOURNAL, 2011, 44 (06) : 510 - 518
  • [23] Comparison of working length determination with radiographs and two electronic apex locators
    Vieyra, J. P.
    Acosta, J.
    Mondaca, J. M.
    INTERNATIONAL ENDODONTIC JOURNAL, 2010, 43 (01) : 16 - 20
  • [24] The influence of two forms of chlorhexidine on the accuracy of contemporary electronic apex locators
    Marek, Ewa
    Lagocka, Ryta
    Kot, Katarzyna
    Wozniak, Krzysztof
    Lipski, Mariusz
    BMC ORAL HEALTH, 2019, 20 (01)
  • [25] The influence of two forms of chlorhexidine on the accuracy of contemporary electronic apex locators
    Ewa Marek
    Ryta Łagocka
    Katarzyna Kot
    Krzysztof Woźniak
    Mariusz Lipski
    BMC Oral Health, 20
  • [26] Influence of Hand File Size on the Accuracy of Root ZX and iPex Electronic Apex Locators: An In Vitro Study
    Siddiqui, Amna Y.
    Alothmani, Osama S.
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (05)
  • [27] Influence of different sized files on the accuracy of two electronic apex locators
    Orosco, Fernando A.
    da Silva, Guilherme F.
    Weckwerth, Paulo H.
    Lopes, Maria Thereza M.
    Garcia, Alan M. R.
    Duarte, Marco Antonio H.
    de Moraes, Ivaldo G.
    AUSTRALIAN ENDODONTIC JOURNAL, 2018, 44 (03) : 251 - 254
  • [28] Comparative evaluation of the accuracy of electronic apex locators and cone-beam computed tomography in detection of root canal perforation and working length during endodontic retreatment
    Koc, Simay
    Harorli, Hatice
    Kustarci, Alper
    BMC ORAL HEALTH, 2024, 24 (01):
  • [29] Accuracy and Repeatability of 3 Apex Locators in Locating Root Canal Perforations: An Ex Vivo Study
    Cunha D'Assuncao, Fabio Luiz
    Nascimento Sousa, Julio Cezar
    Amaro Felinto, Kayo Cesar
    de Medeiros, Thiago Clistines
    Leite, Diego Tavares
    de Lucena, Raissa Bezerra
    Lima, Joab de Oliveira
    JOURNAL OF ENDODONTICS, 2014, 40 (08) : 1241 - 1244
  • [30] Determination of the Accuracy of 5 Electronic Apex Locators in the Function of Different Employment Protocols
    Oliveira, Tiago Nepomuceno
    Vivacqua-Gomes, Nilton
    Bernardes, Ricardo Affonso
    Vivan, Rodrigo Ricci
    Hungaro Duarte, Marco Antonio
    Vasconcelos, Bruno Carvalho
    JOURNAL OF ENDODONTICS, 2017, 43 (10) : 1663 - 1667