Comparison of biodegradable and metallic tension-band fixation for paediatric lateral condyle fracture of the elbow

被引:1
|
作者
Kassai, Tamas [1 ]
Krupa, Zsofia [1 ]
Jozsa, Gergo [2 ]
Hanna, Daniel [3 ]
Varga, Marcell [1 ]
机构
[1] Manninger Jeno, Dept Pediat Trauma Surg, Baleseti Kozpont, Budapest, Hungary
[2] Univ Pecs, Sch Med, Div Paediat Surg Traumatol Urol & Paediat Otolary, Dept Paediat, Pecs, Hungary
[3] Univ Pecs, Med Sch Pecsi Tudomanyegyet, Pecs, Hungary
关键词
Biodegradable implants; Paediatric elbow; Lateral condyle fracture; Tension-band fixation; Fracture; Bioresorbable; FOREIGN-BODY REACTION; BIOABSORBABLE FIXATION; FOREARM FRACTURES; IMPLANTS; HUMERUS; SURGERY;
D O I
10.1016/j.injury.2024.111403
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Introduction: In our retrospective study we compared the outcomes of paediatric lateral condyle fractures of the elbow fixed by bioabsorbable pins and tension-band sutures or by metallic tension-band with K-wires. Materials and methods: We reviewed the data of children operated on for lateral condyle fractures between 2010 and 2020. Patients were classified as follows: 1. fractures treated with metallic (KW group), 2. fractures treated with resorbable implants (BR group). We compared the distribution of age, sex and fracture type in each group. Operative times of the two techniques were also recorded and compared. We analysed the X-rays taken one year after the injury and measured the following parameters: presence of possible non-union, varus or valgus deviation, lateral spur formation. Patients whose follow-up period was less than one year were excluded. For categorical data, group comparisons were performed with Chi-square test or Fisher's exact test, depending on the sample size. The evaluation of discrete variables was performed with Mann-Whitney U test. Results: 42 patients met the above criteria. We found 19 children in the Kirschner -wire + tansion band wire (KW) group and 23 in the Bioresorbable pin + tension band suture (BR) group. There were no significant differences between the study groups in terms of age, sex, left-right ratio, number of complications, operation time, number of Jacobs II and III cases or follow-up time. The operation time was on average 5 min longer in the bioresorbable group (K-wire mean = 62.1 min, Bioresorbable mean = 67 min), this difference, however, is not statistically significant (P = 0.177). In terms of minor and major complications, there was no statistically significant difference between the two groups. (P = 0.729). Conclusions: We did not notice any difference between the complication rates of the two methods, so the real advantage of the absorbable implant technique is that no second intervention is necessary. The benefits of using biodegradable implants in various osteosynthesis techniques need further confirmation by randomised trials.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] POSTEROLATERAL DISLOCATION OF THE ELBOW WITH CONCOMITANT FRACTURE OF THE LATERAL HUMERAL CONDYLE - CASE-REPORT
    VANHAAREN, ERM
    VANVUGT, AB
    BODE, PJ
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 1994, 36 (02): : 288 - 290
  • [42] Management of nail-bed fracture-lacerations using a tension-band suture
    Bindra, RR
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1996, 21A (06): : 1111 - 1113
  • [43] Elbow Dislocation With an Associated Lateral Condyle Fracture of the Humerus: A Rare Occurrence in the Pediatric Population
    Silva, Mauricio
    Cooper, Shannon D.
    Cha, Angela
    JOURNAL OF PEDIATRIC ORTHOPAEDICS, 2015, 35 (04) : 329 - 333
  • [44] Comparison of Kirschner wires and AO cannulated screw internal fixation for displaced lateral humeral condyle fracture in children
    Wen Chao Li
    Rui Jiang Xu
    International Orthopaedics, 2012, 36 : 1261 - 1266
  • [45] Tension band wire fixation for anterior cruciate ligament avulsion fracture: biomechanical comparison of four fixation techniques
    Gan, Yudong
    Xu, Dachuan
    Ding, Jing
    Xu, Yongqing
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2012, 20 (05) : 909 - 915
  • [46] Tension band wire fixation for anterior cruciate ligament avulsion fracture: biomechanical comparison of four fixation techniques
    Yudong Gan
    Dachuan Xu
    Jing Ding
    Yongqing Xu
    Knee Surgery, Sports Traumatology, Arthroscopy, 2012, 20 : 909 - 915
  • [47] Comparison of Kirschner wires and AO cannulated screw internal fixation for displaced lateral humeral condyle fracture in children
    Li, Wen Chao
    Xu, Rui Jiang
    INTERNATIONAL ORTHOPAEDICS, 2012, 36 (06) : 1261 - 1266
  • [48] Kirschner Wire Fixation with and without Tension Band Wiring for Treatment of Fracture of the Lateral Humeral Condylc in Children
    Tomori, Yuji
    Nanno, Mitsuhiko
    Takai, Shinro
    JOURNAL OF NIPPON MEDICAL SCHOOL, 2020, 87 (01) : 17 - 23
  • [49] Complications Following Tension-Band Fixation of Patellar Fractures with Cannulated Screws Compared with Kirschner Wires
    Hoshino, C. Max
    Tiberi, John V., III
    Black, Mary Helen
    Li, Bonnie H.
    Gold, Stuart M.
    Navarro, Ronald A.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2013, 95A (07): : 653 - 659
  • [50] Comparison of metal versus absorbable implants in tension-band wiring: A preliminary study
    Morgan, WJ
    Slowman, LAS
    Wotton, HM
    Nairus, J
    ORTHOPEDICS, 2001, 24 (04) : 383 - 384