Comparison of biodegradable and metallic tension-band fixation for paediatric lateral condyle fracture of the elbow

被引:1
|
作者
Kassai, Tamas [1 ]
Krupa, Zsofia [1 ]
Jozsa, Gergo [2 ]
Hanna, Daniel [3 ]
Varga, Marcell [1 ]
机构
[1] Manninger Jeno, Dept Pediat Trauma Surg, Baleseti Kozpont, Budapest, Hungary
[2] Univ Pecs, Sch Med, Div Paediat Surg Traumatol Urol & Paediat Otolary, Dept Paediat, Pecs, Hungary
[3] Univ Pecs, Med Sch Pecsi Tudomanyegyet, Pecs, Hungary
关键词
Biodegradable implants; Paediatric elbow; Lateral condyle fracture; Tension-band fixation; Fracture; Bioresorbable; FOREIGN-BODY REACTION; BIOABSORBABLE FIXATION; FOREARM FRACTURES; IMPLANTS; HUMERUS; SURGERY;
D O I
10.1016/j.injury.2024.111403
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Introduction: In our retrospective study we compared the outcomes of paediatric lateral condyle fractures of the elbow fixed by bioabsorbable pins and tension-band sutures or by metallic tension-band with K-wires. Materials and methods: We reviewed the data of children operated on for lateral condyle fractures between 2010 and 2020. Patients were classified as follows: 1. fractures treated with metallic (KW group), 2. fractures treated with resorbable implants (BR group). We compared the distribution of age, sex and fracture type in each group. Operative times of the two techniques were also recorded and compared. We analysed the X-rays taken one year after the injury and measured the following parameters: presence of possible non-union, varus or valgus deviation, lateral spur formation. Patients whose follow-up period was less than one year were excluded. For categorical data, group comparisons were performed with Chi-square test or Fisher's exact test, depending on the sample size. The evaluation of discrete variables was performed with Mann-Whitney U test. Results: 42 patients met the above criteria. We found 19 children in the Kirschner -wire + tansion band wire (KW) group and 23 in the Bioresorbable pin + tension band suture (BR) group. There were no significant differences between the study groups in terms of age, sex, left-right ratio, number of complications, operation time, number of Jacobs II and III cases or follow-up time. The operation time was on average 5 min longer in the bioresorbable group (K-wire mean = 62.1 min, Bioresorbable mean = 67 min), this difference, however, is not statistically significant (P = 0.177). In terms of minor and major complications, there was no statistically significant difference between the two groups. (P = 0.729). Conclusions: We did not notice any difference between the complication rates of the two methods, so the real advantage of the absorbable implant technique is that no second intervention is necessary. The benefits of using biodegradable implants in various osteosynthesis techniques need further confirmation by randomised trials.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Comparison of biodegradable and metallic tension-band fixation for patella fractures - 38 patients followed for 2 years
    Chen, AM
    Hou, CL
    Bao, JL
    Guo, SH
    ACTA ORTHOPAEDICA SCANDINAVICA, 1998, 69 (01): : 39 - 42
  • [2] TENSION-BAND PRINCIPLE IN FIXATION OF AN EQUINE ULNAR FRACTURE
    JOHNSON, JH
    BUTLER, HC
    VETERINARY MEDICINE & SMALL ANIMAL CLINICIAN, 1971, 66 (06): : 552 - &
  • [3] TENSION-BAND FIXATION OF OLECRANON FRACTURES - A CADAVER STUDY OF ELBOW EXTENSION
    COLEMAN, NP
    WARREN, PJ
    ACTA ORTHOPAEDICA SCANDINAVICA, 1991, 62 (01): : 58 - 59
  • [4] Elbow Fracture in Children, Lateral Condyle Fracture
    Ruche, V.
    Gouverneur, J.
    Mongiat, R.
    ANNALES FRANCAISES DE MEDECINE D URGENCE, 2018, 8 (01): : 55 - 56
  • [5] Paediatric lateral condyle fracture with a posterolateral elbow dislocation: an atypical injury in a preadolescent
    Wiekrykas, Bradley D.
    Campbell, Nancy
    Greenhill, Dustin A.
    BMJ CASE REPORTS, 2021, 14 (05)
  • [6] Biomechanical comparison of pin and tension-band wire fixation with a prototype locking plate fixation in a transverse canine patellar fracture model
    Gibert, Sophie
    Kowaleski, Michael P.
    Matthys, Romano
    Nuetzi, Reto
    Serck, Boris
    Boudrieau, Randy J.
    VETERINARY AND COMPARATIVE ORTHOPAEDICS AND TRAUMATOLOGY, 2016, 29 (01) : 20 - 28
  • [7] TENSION-BAND WIRE FIXATION OF OLECRANON FRACTURES
    Carter, Tom H.
    Molyneux, Samuel G.
    Reid, Jeffrey T.
    White, Timothy O.
    Duckworth, Andrew D.
    JBJS ESSENTIAL SURGICAL TECHNIQUES, 2018, 8 (03):
  • [8] TENSION-BAND WIRING AND LAG SCREW FIXATION OF A TRANSVERSE, COMMINUTED FRACTURE OF A PATELLA IN A HORSE
    HUNT, RJ
    BAXTER, GM
    ZAMOS, DT
    JOURNAL OF THE AMERICAN VETERINARY MEDICAL ASSOCIATION, 1992, 200 (06) : 819 - 820
  • [9] A Tension-Band Wiring Technique for Direct Fixation of a Chaput Tubercle Fracture: Technical Note
    Yeo, Eui-Dong
    Jung, Ki-Jin
    Hong, Yong-Cheol
    Hong, Chang-Hwa
    Lee, Hong-Seop
    Won, Sung-Hun
    Yoon, Sung-Joon
    Kim, Sung-Hwan
    Ji, Jae-Young
    Lee, Dhong-Won
    Kim, Woo-Jong
    MEDICINA-LITHUANIA, 2022, 58 (08):
  • [10] Fractures of the olecranon: An in vitro study of elbow joint stresses after tension-band wire fixation versus proximal fracture fragment excision
    Moed, BR
    Ede, DE
    Brown, TD
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2002, 53 (06): : 1088 - 1093