Multi-mode high resolution TFM imaging of microdefects based on laser ultrasonic full matrix capture

被引:0
|
作者
Liu, Zenghua [1 ]
Chen, Long [2 ]
Zhu, Yanping [1 ]
Liu, Xiaoyu [2 ]
He, Cunfu [1 ]
机构
[1] Beijing Univ Technol, Sch Informat Sci & Technol, Beijing 100124, Peoples R China
[2] Beijing Univ Technol, Coll Mech & Energy Engn, Beijing 100124, Peoples R China
来源
基金
中国国家自然科学基金;
关键词
Laser ultrasonic; Multi-mode imaging; Microdefect; Full matrix capture; Multi-scale principal component analysis; DEFECTS;
D O I
10.1016/j.optlastec.2024.111913
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The identification and visualization of submillimeter microdefects have long been a critical focus within the realm of ultrasonic testing. The utilization of high-frequency signals is imperative due to the small acoustic interaction structure. An additional benefit of using lasers is their non-contact nature and ability to utilize multiple imaging modes, effectively reducing false or missed detections and enhancing credibility. This study proposes an advanced optimization algorithm for imaging and quantitative evaluation of submillimeter microdefects using laser ultrasonic full matrix capture (FMC) and total focusing method (TFM). The analysis of acoustic directionality under laser excitation and detection provides a foundation for mode selection. In preprocessing, the multi-scale principal component analysis (MSPCA) method is introduced to suppress coherent noise and blind spots. Moreover, phase coherence methods are implemented to further reduce mode artifacts, background noise, and residual surface acoustic wave (SAW). Additionally, multi-mode imaging and mode fusion are achieved using reflected longitudinal waves, reflected shear waves, converted longitudinal waves, and converted shear waves. Experiments were carried out on two different types of microdefects, namely side drilled holes (SDHs) and blind holes (BHs), resulting in high resolution TFM imaging with a minimum BH size of 0.3 mm. The outcomes demonstrate the efficacy of MSPCA in suppressing coherent noise, with further enhancement in imaging quality after phase coherence weighting. In addition, the -6 dB threshold of multi-mode images also provided the size information. This research is poised to contribute to the resolution of quality assessment challenges in powder metallurgy, welding, and additive manufacturing processes.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Design of a Multi-mode Block Adaptive Quantizer for High-Resolution Synthetic Aperture Radar Imaging
    Pei-Yun Tsai
    Meng-Yuan Huang
    Yu-Liang Tsai
    Ching-Horng Lee
    Li-Mei Chen
    Sz-Yuan Lee
    Journal of Signal Processing Systems, 2019, 91 : 673 - 683
  • [22] Multi-mode fibre laser Doppler anemometer (LDA) with high spatial resolution for the investigation of boundary layers
    L. Büttner
    J. Czarske
    Experiments in Fluids, 2004, 36 : 214 - 216
  • [23] Design of a Multi-mode Block Adaptive Quantizer for High-Resolution Synthetic Aperture Radar Imaging
    Tsai, Pei-Yun
    Huang, Meng-Yuan
    Tsai, Yu-Liang
    Lee, Ching-Horng
    Chen, Li-Mei
    Lee, Sz-Yuan
    JOURNAL OF SIGNAL PROCESSING SYSTEMS FOR SIGNAL IMAGE AND VIDEO TECHNOLOGY, 2019, 91 (06): : 673 - 683
  • [24] Multi-mode fibre laser Doppler anemometer (LDA) with high spatial resolution for the investigation of boundary layers
    Büttner, L
    Czarske, J
    EXPERIMENTS IN FLUIDS, 2004, 36 (01) : 214 - 216
  • [25] High-resolution multi-mode SAR system designing method
    Li, Wei
    Li, Chunsheng
    Chen, Jie
    Yu, Ze
    Beijing Hangkong Hangtian Daxue Xuebao/Journal of Beijing University of Aeronautics and Astronautics, 2010, 36 (01): : 104 - 109
  • [26] Preprocessing of the full matrix capture data for time-reversal-based super-resolution imaging
    Fan, Chengguang
    Yang, Lei
    Zhao, Yong
    INSIGHT, 2017, 59 (11) : 586 - 590
  • [27] Multi-mode ultrasonic visualization of porosity in composites using a focused transducer with high sensitivity and near-surface resolution
    Shi, Junwei
    Liu, Songping
    Liu, Feifei
    Xun, Guoli
    COMPOSITES PART C: OPEN ACCESS, 2021, 4
  • [28] Multi-mode reverse time migration damage imaging using ultrasonic guided waves
    He, Jiaze
    Leckey, Cara A. C.
    Leser, Patrick E.
    Leser, William P.
    ULTRASONICS, 2019, 94 : 319 - 331
  • [29] Ultrasonic Bubble Imaging in Molten Salt Using a Multi-Mode Waveguide and Time Reversal
    Grueter, Lars
    Nauber, Richard
    Czarske, Juergen W.
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2022, 71
  • [30] Multi Frequency Standing Wave Ultrasonic Imaging based Full-Field Laser Scanning
    Im, Seong Jin
    Jeon, Jun Young
    Park, Gyuhae
    Kang, To
    Han, Soon Woo
    JOURNAL OF THE KOREAN SOCIETY FOR NONDESTRUCTIVE TESTING, 2020, 40 (02) : 112 - 121