A comparative study of helical and spiral flow paths in solar air heaters: Experimental testing and CFD modeling

被引:0
|
作者
Ben Amara, Walid [1 ]
Bouabidi, Abdallah [1 ]
Chrigui, Mouldi [1 ]
Cuce, Erdem [2 ,3 ,4 ,5 ]
机构
[1] Univ Gabes, Natl Sch Engineers Gabes ENIG, Mech Modelling Energy & Mat Lab LM2EM, LR24ES23, Ave Omar Ib Elkhattab, Gabes 6023, Tunisia
[2] Recep Tayyip Erdogan Univ, Fac Engn & Architecture, Dept Mech Engn, Zihni Derin Campus, TR-53100 Rize, Turkiye
[3] Chandigarh Univ, Univ Ctr Res & Dev, Mohali 140413, Punjab, India
[4] Chitkara Univ, Ctr Res Impact & Outcome, Rajpura 140401, Punjab, India
[5] Saveetha Univ, Saveetha Inst Med & Tech Sci, Saveetha Sch Engn, Dept Mech Engn, Chennai, India
关键词
Experimental testing; Numerical model; Outlet air temperature; Pressure losses; Solar air heaters; Spiral and helical flow path; Thermal performance; THERMAL PERFORMANCE; COLLECTOR;
D O I
10.1016/j.renene.2025.122642
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This study conducted a comparative analysis of Solar Air Heaters (SAHs) with Spiral and Helical flow paths. It evaluates their thermal performance and pressure drop, providing new insights for SAH design and optimization. The prototypes were constructed and tested at the Mechanical Modelling, Energy & Materials (M2EM) Laboratory in Gabes, Tunisia. A numerical model was developed using ANSYS Fluent 2021 R1. The mesh independence was analyzed to ensure accuracy of the numerical results. The results demonstrated excellent agreement between numerical and experimental data, with an average deviation of 4.5 %. The experimental results indicated that the maximum air temperature attained 76.2 degrees C and 72 degrees C for the HSAH and the SSAH, respectively at a mass flow rate of 0.01 kg/s. The numerical results showed an increase in air temperature of 62 degrees C and 59.4 degrees C for the HSAH and SSAH, respectively, at a mass flow rate of 0.005 kg/s. At higher flow rates, both systems exhibited closer air temperature. Pressure loss analysis showed that the HSAH incurred higher losses (1797.7 Pa) compared to the SSAH (927 Pa) at a mass flow rate of 0.03 kg/s. Consequently, the pumping power was 22 W and 44 W for the SSAH and the HSAH, respectively. In addition, the thermal efficiencies of the two systems became identical at higher flow rates and reached 65 % at a mass flow rate of 0.03 kg/s. Therefore, this study highlights the superiority of the spiral flow path design in terms of thermal efficiency and lower pressure losses compared to the helical configuration.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] Modeling and experimental study of a triangular channel solar air heater
    Akhbari, Mitra
    Rahimi, Amir
    Hatamipour, Mohammad Sadegh
    APPLIED THERMAL ENGINEERING, 2020, 170
  • [32] Experimental study of the thermal performance of spiral flow solar water heating system
    Abdulsitar, Ahmed
    Hasan, Nofal
    Basem, Ali
    Daabo, Ahmed
    Yaseen, Abdulelah
    Hamzah, Hudhaifa
    MRS ENERGY & SUSTAINABILITY, 2024, 11 (02) : 554 - 564
  • [33] CFD modeling of contaminant capture with an air flow control valve in a full-scale kitchen: An experimental and numerical study
    Ozbakis, Yusuf
    Erzincanli, Fehmi
    SCIENTIA IRANICA, 2024, 31 (16) : 1374 - 1386
  • [34] Heat transfer and air flow friction in solar air heaters: A comprehensive computational and experimental investigation with wire-roughened absorber plate
    Abulkhair, Hani
    Alsaiari, Abdulmohsen O.
    Ahmed, Iqbal
    Almatrafi, Eydhah
    Madhukeshwara, N.
    Sreenivasa, B. R.
    CASE STUDIES IN THERMAL ENGINEERING, 2023, 48
  • [35] Numerical and experimental study of the heat transfer and hydraulic performance of solar air heaters with different baffle positions
    Bensaci, Charaf-Eddine
    Moummi, Abdelhafid
    Sanchez de la Flor, Francisco J.
    Rodriguez Jara, Enrique A.
    Rincon-Casado, Alejandro
    Ruiz-Pardo, Alvaro
    RENEWABLE ENERGY, 2020, 155 : 1231 - 1244
  • [36] Analytical and Experimental Study of Recycling Baffled Double-Pass Solar Air Heaters with Attached Fins
    Ho, Chii Dong
    Chang, Hsuan
    Wang, Rei Chi
    Lin, Chun Sheng
    ENERGIES, 2013, 6 (04): : 1821 - 1842
  • [37] Measurement and analysis of thermal-hydraulic performance of curved and plate flat solar air heaters; a comparative study
    Guellai F.
    Labed A.
    Moummi N.
    Mahboub C.
    Instrumentation Mesure Metrologie, 2019, 18 (06): : 553 - 558
  • [38] CFD modeling and experimental study of resin-bonded sand/air two-phase flow in sand coremaking process
    Bakhtiyarov, SI
    Overfelt, RA
    POWDER TECHNOLOGY, 2003, 133 (1-3) : 68 - 78
  • [39] Computional simulation and experimental study on air flow organization for spiral quick-freezer
    Huan, ZJ
    He, SS
    ENERGY CONVERSION AND APPLICATION, VOL I AND II, 2001, : 1123 - 1127
  • [40] Experimental study on laminar air flow through spiral channel packed with steel balls
    Mustafa Yasin Gökaslan
    Mustafa Özdemir
    Lütfullah Kuddusi
    Heat and Mass Transfer, 2021, 57 : 1453 - 1465