Point-of-Care Tests for Preeclampsia: Systematic Review and Meta-Analysis of Diagnostic Test Accuracy Studies

被引:0
|
作者
Elbarbary, Nouran [1 ]
Pritsini, Filippa [2 ]
Kazi, Ayisha [1 ]
Wang, Chao [3 ]
Thilaganathan, Baskaran [1 ]
Bhide, Amarnath [1 ]
机构
[1] St Georges Univ Hosp, Fetal Med Unit, London, England
[2] Kings Coll Univ Hosp, Obstet & Gynaecol Dept, LONDON, England
[3] Kingston Univ, Fac Hlth Sci Social Care & Educ, London, England
关键词
glycosylated fibronectin; point of care; preeclampsia; PLACENTAL GROWTH-FACTOR; ANGIOGENIC FACTORS; WOMEN; SPECIFICITY; SENSITIVITY; MODEL;
D O I
10.1111/1471-0528.18040
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
BackgroundPreeclampsia is a common condition associated with significant maternal and foetal complications. The diagnosis of preeclampsia is based on clinical criteria, with recent introduction of angiogenic markers as an aid to clinical triage. Several biomarkers are now available in a point-of-care test format, which provide swift results to support clinical decision-making.ObjectivesTo determine sensitivity and specificity of available point-of-care tests used for preeclampsia prediction.Search StrategySystematic searches of databases (PubMed/Medline, Ovid Embase) from inception till May 2024 were done to identify relevant studies. Selection criteria: we included studies reporting on the diagnostic test accuracy of any point-of-care test for short-term prediction of preeclampsia in the second or third trimester.Data Collection and AnalysisData were extracted using pre-designed template, and statistical analysis was performed to pool sensitivity and specificity and a hierarchal summary receiver operating characteristic curve model was used. Quality of included studies and risk of bias were assessed following the QUADAS-2 tool.Main ResultsWe identified 17 studies that met the inclusion criteria, six of which described the use of glycosylated fibronectin, five with Congo red, two with placental growth factor (PlGF) and one study each investigated nephrin, misfolded protein, CD44/FKBPL ratio and inositol phosphoglycan-P. Meta-analysis was possible only for glycosylated fibronectin with a pooled sensitivity of 0.80 (95% CI: 0.51-0.94) and a specificity of 0.84 (95% CI: 0.71-0.93). Five studies were included in meta-analysis, all of which had a low risk of bias on the QUADAS assessment.ConclusionsThese findings suggest that the point-of-care glycosylated fibronectin testing might be beneficial in clinical triage for preeclampsia in an at-risk population.
引用
收藏
页码:414 / 425
页数:12
相关论文
共 50 条
  • [21] Diagnostic accuracy of point-of-care lung ultrasound for COVID-19: a systematic review and meta-analysis
    Matthies, Ashley
    Trauer, Michael
    Chopra, Karl
    Jarman, Robert David
    EMERGENCY MEDICINE JOURNAL, 2023, 40 (06) : 407 - +
  • [22] Impact of point-of-care panel tests in ambulatory care: a systematic review and meta-analysis
    Goyder, Clare
    Tan, Pui San
    Verbakel, Jan
    Ananthakumar, Thanusha
    Lee, Joseph J.
    Hayward, Gail
    Turner, Philip J.
    Van Den Bruel, Ann
    BMJ OPEN, 2020, 10 (02):
  • [23] Impact of point-of-care tests in community pharmacies: a systematic review and meta-analysis
    Albasri, Ali
    Van den Bruel, Ann
    Hayward, Gail
    McManus, Richard J.
    Sheppard, James Peter
    Verbakel, Jan Yvan Jos
    BMJ OPEN, 2020, 10 (05):
  • [24] A systematic review and meta-analysis of studies evaluating the performance of point-of-care tests for human papillomavirus screening
    Kelly, Helen
    Mayaud, Philippe
    Segondy, Michel
    Pai, Nitika Pant
    Peeling, Rosanna W.
    SEXUALLY TRANSMITTED INFECTIONS, 2017, 93 : S36 - S45
  • [25] Diagnostic Accuracy of Point-of-Care Ultrasound (POCUS) in Patients With Respiratory Tract Disorders - A Systematic Review and Meta-analysis
    Malik, F. A.
    Raheem, A.
    Selvam, S.
    Patel, U. K.
    Mahmood, S.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2023, 207
  • [26] Diagnostic Accuracy of Point-of-Care HCV Viral Load Assays for HCV Diagnosis: A Systematic Review and Meta-Analysis
    Tang, Weiming
    Tao, Yusha
    Fajardo, Emmanuel
    Reipold, Elena Ivanova
    Chou, Roger
    Tucker, Joseph D.
    Easterbrook, Philippa
    DIAGNOSTICS, 2022, 12 (05)
  • [27] Diagnostic Accuracy of Point-of-Care Ultrasound for Intussusception in Children Presenting to the Emergency Department: A Systematic Review and Meta-analysis
    Lin-Martore, Margaret
    Kornblith, Aaron E.
    Kohn, Michael A.
    Gottlieb, Michael
    WESTERN JOURNAL OF EMERGENCY MEDICINE, 2020, 21 (04) : 1008 - 1016
  • [28] Diagnostic accuracy of point-of-care devices for detection of anemia in children in community settings: a systematic review and meta-analysis
    Panda, Prateek Kumar
    Sharawat, Indar Kumar
    Pradhan, Pranita
    Malik, Vivek Singh
    Singh, Meenu
    EUROPEAN JOURNAL OF PEDIATRICS, 2024, 184 (01)
  • [29] The Clinical Utility of Point-of-Care Tests for Influenza in Ambulatory Care: A Systematic Review and Meta-analysis
    Lee, Joseph Jonathan
    Verbakel, Jan Y.
    Goyder, Clare Rosemary
    Ananthakumar, Thanusha
    Tan, Pui San
    Turner, Phillip James
    Hayward, Gail
    Van den Bruel, Ann
    CLINICAL INFECTIOUS DISEASES, 2019, 69 (01) : 24 - 33
  • [30] Accuracy of Point-of-care Ultrasonography for Diagnosing Acute Appendicitis: A Systematic Review and Meta-analysis
    Fields, J. Matthew
    Davis, Joshua
    Alsup, Carl
    Bates, Amanda
    Au, Arthur
    Adhikari, Srikar
    Farrell, Isaac
    ACADEMIC EMERGENCY MEDICINE, 2017, 24 (09) : 1124 - 1136