Point-of-Care Tests for Preeclampsia: Systematic Review and Meta-Analysis of Diagnostic Test Accuracy Studies

被引:0
|
作者
Elbarbary, Nouran [1 ]
Pritsini, Filippa [2 ]
Kazi, Ayisha [1 ]
Wang, Chao [3 ]
Thilaganathan, Baskaran [1 ]
Bhide, Amarnath [1 ]
机构
[1] St Georges Univ Hosp, Fetal Med Unit, London, England
[2] Kings Coll Univ Hosp, Obstet & Gynaecol Dept, LONDON, England
[3] Kingston Univ, Fac Hlth Sci Social Care & Educ, London, England
关键词
glycosylated fibronectin; point of care; preeclampsia; PLACENTAL GROWTH-FACTOR; ANGIOGENIC FACTORS; WOMEN; SPECIFICITY; SENSITIVITY; MODEL;
D O I
10.1111/1471-0528.18040
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
BackgroundPreeclampsia is a common condition associated with significant maternal and foetal complications. The diagnosis of preeclampsia is based on clinical criteria, with recent introduction of angiogenic markers as an aid to clinical triage. Several biomarkers are now available in a point-of-care test format, which provide swift results to support clinical decision-making.ObjectivesTo determine sensitivity and specificity of available point-of-care tests used for preeclampsia prediction.Search StrategySystematic searches of databases (PubMed/Medline, Ovid Embase) from inception till May 2024 were done to identify relevant studies. Selection criteria: we included studies reporting on the diagnostic test accuracy of any point-of-care test for short-term prediction of preeclampsia in the second or third trimester.Data Collection and AnalysisData were extracted using pre-designed template, and statistical analysis was performed to pool sensitivity and specificity and a hierarchal summary receiver operating characteristic curve model was used. Quality of included studies and risk of bias were assessed following the QUADAS-2 tool.Main ResultsWe identified 17 studies that met the inclusion criteria, six of which described the use of glycosylated fibronectin, five with Congo red, two with placental growth factor (PlGF) and one study each investigated nephrin, misfolded protein, CD44/FKBPL ratio and inositol phosphoglycan-P. Meta-analysis was possible only for glycosylated fibronectin with a pooled sensitivity of 0.80 (95% CI: 0.51-0.94) and a specificity of 0.84 (95% CI: 0.71-0.93). Five studies were included in meta-analysis, all of which had a low risk of bias on the QUADAS assessment.ConclusionsThese findings suggest that the point-of-care glycosylated fibronectin testing might be beneficial in clinical triage for preeclampsia in an at-risk population.
引用
收藏
页码:414 / 425
页数:12
相关论文
共 50 条
  • [1] Systematic Review and Meta-Analysis of Diagnostic Test Accuracy Studies Evaluating Point-of-Care Tests of Coagulopathy in Cardiac Surgery
    Wozniak, Marcin J.
    Abbasciano, Riccardo
    Monaghan, Alexandra
    Lai, Florence Y.
    Corazzari, Claudio
    Tutino, Cassandra
    Kumar, Tracy
    Whiting, Penny
    Murphy, Gavin J.
    TRANSFUSION MEDICINE REVIEWS, 2021, 35 (01) : 7 - 15
  • [2] Point-of-care tests for urinary tract infections: protocol for a systematic review and meta-analysis of diagnostic test accuracy
    Navarro, David Fraile
    Sullivan, Frank
    Azcoaga-Lorenzo, Amaya
    Santiago, Virginia Hernandez
    BMJ OPEN, 2020, 10 (06): : e033424
  • [3] A systematic review and meta-analysis of the diagnostic accuracy of point-of-care tests for the detection of hyperketonemia in dairy cows
    Tatone, Elise H.
    Gordon, Jessica L.
    Hubbs, Jessie
    LeBlanc, Stephen J.
    DeVries, Trevor J.
    Duffield, Todd F.
    PREVENTIVE VETERINARY MEDICINE, 2016, 130 : 18 - 32
  • [4] SYSTEMATIC REVIEW AND META-ANALYSIS OF THE DIAGNOSTIC ACCURACY OF LEPTOSPIROSIS LATERAL FLOW IGM POINT-OF-CARE TESTS
    Maze, Michael
    Sharples, Katrina
    Rubach, Matthew
    Crump, John
    AMERICAN JOURNAL OF TROPICAL MEDICINE AND HYGIENE, 2018, 99 (04): : 156 - 156
  • [5] Diagnostic Accuracy of Point-of-Care Tests for Hepatitis C Virus Infection: A Systematic Review and Meta-Analysis
    Khuroo, Mehnaaz Sultan
    Khuroo, Naira Sultan
    Khuroo, Mohammad Sultan
    PLOS ONE, 2015, 10 (03):
  • [6] Diagnostic Accuracy of Rapid Point-of-Care Tests for Detecting Active Syphilis: A Systematic Review and Meta-Analysis
    Angel-Muller, Edith
    Grillo-Ardila, Carlos Fernando
    Amaya-Guio, Jairo
    Torres-Montanez, Nicolas
    SEXUALLY TRANSMITTED DISEASES, 2021, 48 (12) : E202 - E208
  • [7] Diagnostic accuracy of point-of-care ultrasound for shock: a systematic review and meta-analysis
    Yoshida, Takuo
    Yoshida, Takuya
    Noma, Hisashi
    Nomura, Takeshi
    Suzuki, Akihiro
    Mihara, Takahiro
    CRITICAL CARE, 2023, 27 (01)
  • [8] Diagnostic accuracy of point-of-care ultrasound for shock: a systematic review and meta-analysis
    Takuo Yoshida
    Takuya Yoshida
    Hisashi Noma
    Takeshi Nomura
    Akihiro Suzuki
    Takahiro Mihara
    Critical Care, 27
  • [9] The diagnostic accuracy of isothermal nucleic acid point-of-care tests for human coronaviruses: A systematic review and meta-analysis
    Subsoontorn, Pakpoom
    Lohitnavy, Manupat
    Kongkaew, Chuenjid
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [10] The diagnostic accuracy of isothermal nucleic acid point-of-care tests for human coronaviruses: A systematic review and meta-analysis
    Pakpoom Subsoontorn
    Manupat Lohitnavy
    Chuenjid Kongkaew
    Scientific Reports, 10