Volunteer Responder Recruitment, Voluntary Deployment of Automated External Defibrillators, and Coverage of Out-of-Hospital Cardiac Arrest in Denmark

被引:0
|
作者
Bo, Nanna [1 ,2 ]
Juul Grabmayr, Anne [2 ,4 ]
Folke, Fredrik [2 ,3 ,4 ]
Jakobsen, Louise Kollander [2 ,4 ]
Kjolbye, Julie Samsoe [2 ,4 ]
Sodergren, Shaun Theodor Florentz [1 ,2 ,4 ]
Bundgaard Ringgren, Kristian [6 ,8 ]
Andelius, Linn [2 ,3 ]
Torp-Pedersen, Christian [5 ,6 ]
Tofte Gregers, Mads C. [2 ]
Malta Hansen, Carolina [2 ,3 ,4 ,7 ]
机构
[1] Univ Copenhagen, Fac Hlth & Med Sci, Copenhagen, Denmark
[2] Univ Copenhagen, Copenhagen Emergency Med Serv, Copenhagen, Denmark
[3] Univ Copenhagen, Herlev & Gentofte Hosp, Dept Cardiol, Copenhagen, Denmark
[4] Univ Copenhagen, Dept Clin Med, Copenhagen, Denmark
[5] Univ Copenhagen, North Zealand Hosp, Dept Cardiol, Copenhagen, Denmark
[6] Univ Copenhagen, Dept Publ Hlth, Rigshosp, Copenhagen, Denmark
[7] Univ Copenhagen, Dept Cardiol, Rigshosp, Copenhagen, Denmark
[8] North Denmark Reg Hosp, Dept Anaesthesia & Intens Care, Copenhagen, Denmark
来源
关键词
automated external defibrillators; cardiopulmonary resuscitation; out-of-hospital cardiac arrest; sudden cardiac death; volunteer responders; PUBLIC LOCATIONS; DISPATCH; LAYPERSONS;
D O I
10.1161/JAHA.124.036363
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: A volunteer responder program to out-of-hospital cardiac arrest (OHCA) was implemented stepwise in Denmark (2017-2020). This study assessed automated external defibrillator (AED) and volunteer responder coverage of historical OHCAs in Denmark. Methods: Non-emergency medical services witnessed OHCAs (2016-2020) from the Danish Cardiac Arrest Registry with known location and AEDs from the Danish AED network were included. Volunteer responders with an exact location were identified using the volunteer responder server. A historical OHCA was defined as covered when >= 4 volunteer responders and >= 1 AED were <500 m range. Coverage was examined according to location (public or home), time of day (noon or midnight), and volunteer responder background (lay people or health care professionals). Results: A total of 22 330 OHCAs and 22 418 AEDs (387 AEDs/100 000 inhabitants) were included. At noon, 34 180 volunteer responders (589 volunteer responders/100 000 inhabitants) were identified as available. During daytime, OHCA coverage was 56% (95% CI, 55.9-57.2, n=12 625) decreasing to 30% (95% CI, 29.8-31.0, n=6793) when including only volunteer responders with a health care background. There was no significant difference in coverage according to time of day or location of arrest. OHCA coverage was 85% (95% CI, 84.2-86.0, n=6153) 4 years after implementation (first area included). Conclusion: Regardless of time of day, more than half of all OHCAs were covered by volunteer responders and AEDs in Denmark. Excluding lay volunteers would almost halve the coverage. Our results indicate successful recruitment of volunteer responders and deployment of AEDs with great potential for improving bystander defibrillation.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Inappropriate analyses of automated external defibrillators used during out-of-hospital cardiac arrests
    Ballesteros Pena, Sendoa
    ATENCION PRIMARIA, 2013, 45 (04): : 193 - 198
  • [42] Lay Responder Care for an Adult with Out-of-Hospital Cardiac Arrest
    Brady, William J.
    Mattu, Amal
    Slovis, Corey M.
    NEW ENGLAND JOURNAL OF MEDICINE, 2019, 381 (23): : 2242 - 2251
  • [43] Failure of cardiac rhythm analysis by automated external defibrillator in an out-of-hospital cardiac arrest
    Cmorej, P. Ch.
    Smrzova, E.
    Mach, J.
    ANESTEZIOLOGIE A INTENZIVNI MEDICINA, 2018, 29 (03): : 135 - 138
  • [44] Surviving out-of-hospital cardiac arrest: just a matter of defibrillators?
    Zorzi, Alessandro
    Gasparetto, Nicola
    Stella, Federica
    Bortoluzzi, Andrea
    Cacciavillani, Luisa
    Basso, Cristina
    JOURNAL OF CARDIOVASCULAR MEDICINE, 2014, 15 (08) : 616 - 623
  • [45] The effect of the GoodSAM volunteer first-responder app on survival to hospital discharge following out-of-hospital cardiac arrest
    Smith, Christopher M.
    Lall, Ranjit
    Fothergill, Rachael T.
    Spaight, Robert
    Perkins, Gavin D.
    EUROPEAN HEART JOURNAL-ACUTE CARDIOVASCULAR CARE, 2022, 11 (01) : 20 - 31
  • [46] Factors predicting survival of out-of-hospital cardiac arrest managed with semiautomatic external defibrillators in Galicia
    Soto-Araujo, Lorena
    Costa-Parcero, Manuel
    Dolores Gonzalez-Gonzalez, Maria
    Sanchez-Santos, Luis
    Antonio Iglesias-Vazquez, Jose
    Rodriguez-Nunez, Antonio
    EMERGENCIAS, 2015, 27 (05): : 307 - 312
  • [48] Health inequalities in cardiopulmonary resuscitation and use of automated electrical defibrillators in out-of-hospital cardiac arrest
    Zahra, Syeda Anum
    Choudhury, Rozina Yasmin
    Naqvi, Rameez
    Boulton, Adam J.
    Chahal, C. Anwar A.
    Munir, Sabrina
    Carrington, Mafalda
    Ricci, Fabrizio
    Khanji, Mohammed Y.
    CURRENT PROBLEMS IN CARDIOLOGY, 2024, 49 (05)
  • [49] Dispatcher nurses' experiences of handling drones equipped with automated external defibrillators in suspected out-of-hospital cardiac arrest - a qualitative study
    Hanna, Dalby-Pedersen
    Erika, Bergstrom
    Ellinor, Berglund
    Sofia, Schierbeck
    Leif, Svensson
    Anette, Nord
    Jacob, Hollenberg
    Andreas, Claesson
    SCANDINAVIAN JOURNAL OF TRAUMA RESUSCITATION & EMERGENCY MEDICINE, 2024, 32 (01):
  • [50] Analysis of bystander CPR quality during out-of-hospital cardiac arrest using data derived from automated external defibrillators
    Fernando, Shannon M.
    Vaillancourt, Christian
    Morrow, Stanley
    Stiell, Ian G.
    RESUSCITATION, 2018, 128 : 138 - 143