Bond Performance of GFRP Bars in Glass and Basalt Fiber-Reinforced Geopolymer Concrete Under Hinged Beam Tests

被引:0
|
作者
Erturkmen, Duygu [1 ]
Urunveren, Husamettin [2 ]
Beycioglu, Ahmet [2 ]
Ibadov, Nabi [3 ]
Aruntas, Hueseyin Yilmaz [4 ]
Garbacz, Andrzej [5 ]
机构
[1] Mersin Univ, Fac Engn, Dept Civil Engn, TR-33343 Mersin, Turkiye
[2] Adana Alparslan Turkes Sci & Technol Univ, Fac Engn, Dept Civil Engn, TR-01250 Adana, Turkiye
[3] Warsaw Univ Technol, Fac Civil Engn, Dept Prod Engn & Management Construct, Al Armii Ludowej 16, PL-00637 Warsaw, Poland
[4] Gazi Univ, Fac Technol, Dept Civil Engn, TR-06500 Ankara, Turkiye
[5] Warsaw Univ Technol, Fac Civil Engn, Dept Bldg Mat Engn, Al Armii Ludowej 16, PL-00637 Warsaw, Poland
关键词
GFRP bars; geopolymer concrete; chopped basalt fiber; chopped glass fiber; bond stress; hinged beam test; POLYMER BARS; BEHAVIOR; STRENGTH;
D O I
10.3390/ma18030498
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
In recent years, researchers have focused on the usability of fiber-reinforced polymer (FRP) bars due to their lightweight, corrosion-resistant, and eco-friendly characteristics. Geopolymers, as low-carbon alternatives to traditional binders, aim to reduce CO2 emissions in concrete production. The bond strength between FRP bars and concrete is critical for the load-bearing capacity and deformation characteristics of reinforced elements. The objectives of this work are to investigate the bond performance of GFRP bars in chopped glass and basalt fiber-added geopolymer concrete using hinged beam tests. Since the hinged beam test accurately represents the behavior of real bending elements, this test method was selected as a main bonding test. Initially, three geopolymer mixtures with Ms modulus values of 1.2, 1.3, and 1.4 were prepared and tested. The mixture with a modulus of 1.2 Ms, achieving a compressive strength of 56.53 MPa, a flexural strength of 3.54 MPa, and a flow diameter of 57 cm, was chosen for beam production due to its optimal workability and strength. After mechanical and workability tests, SEM analysis was performed to evaluate its internal structure. For evaluating the bond performance of GFRP bars, 12 geopolymer beam specimens were prepared, incorporating varying fiber types (chopped glass fiber or basalt fiber) and embedment lengths (5 & Oslash; or 20 & Oslash;). Hinged beam tests revealed that the bond strengths of glass and basalt fiber-added mixtures were up to 49% and 37% higher than that of the control geopolymer concrete, respectively. It was concluded that incorporating fibers positively influenced the bond between geopolymer concrete and GFRP bars, with glass fibers proving more effective than basalt fibers. These findings enhance the understanding of bond mechanisms between GFRP bars and geopolymer concrete, emphasizing their potential for sustainable and durable construction in both industrial and scientific applications.
引用
收藏
页数:24
相关论文
共 50 条
  • [31] Bond behavior of recycled tyre steel fiber reinforced concrete and basalt fiber-reinforced polymer bars under static and fatigue loading conditions
    Soltanzadeh, Fatemeh
    Edalat-Behbahani, Ali
    Pereira, Eduardo N. B.
    JOURNAL OF BUILDING ENGINEERING, 2023, 70
  • [32] Structural Performance of Lightweight Aggregate Concrete Reinforced by Glass or Basalt Fiber Reinforced Polymer Bars
    Abed, Mohammed A.
    Anagreh, Aysha
    Tosic, Nikola
    Alkhabbaz, Ola
    Alshwaiki, Majd Eddin
    Cerny, Robert
    POLYMERS, 2022, 14 (11)
  • [33] Bond Behavior of Basalt Fiber-Reinforced Polymer Bars Embedded in Concrete Under Mono-tensile and Cyclic Loads
    Xia Liu
    Xin Wang
    Kangyu Xie
    Zhishen Wu
    Feng Li
    International Journal of Concrete Structures and Materials, 2020, 14
  • [34] Bond Behavior of Basalt Fiber-Reinforced Polymer Bars Embedded in Concrete Under Mono-tensile and Cyclic Loads
    Liu, Xia
    Wang, Xin
    Xie, Kangyu
    Wu, Zhishen
    Li, Feng
    INTERNATIONAL JOURNAL OF CONCRETE STRUCTURES AND MATERIALS, 2020, 14 (01)
  • [35] Bond Behavior of Basalt Fiber-Reinforced Polymer Bars Embedded in Concrete Under Mono-tensile and Cyclic Loads
    Liu, Xia
    Wang, Xin
    Xie, Kangyu
    Wu, Zhishen
    Li, Feng
    10TH INTERNATIONAL CONFERENCE ON FRP COMPOSITES IN CIVIL ENGINEERING (CICE 2020/2021), 2022, 198 : 158 - 180
  • [36] Investigation on performance of basalt fiber-reinforced concrete under fatigue load
    Li, Zhennan
    Yu, Feng
    Dai, Xiaoqian
    Shen, Aiqin
    Wang, Xiushan
    MATERIALS AND STRUCTURES, 2025, 58 (03)
  • [37] Research on the bond performance between glass fiber reinforced polymer (GFRP) bars and Ultra-high performance concrete(UHPC)
    Xiao, Jie
    Liu, Lingfei
    Zeng, Hehui
    Zhai, Keyi
    Fu, Jundong
    Jiang, Haibo
    Pang, Lei
    JOURNAL OF BUILDING ENGINEERING, 2024, 98
  • [38] Concrete Contribution to Shear Strength of Beams Reinforced with Basalt Fiber-Reinforced Bars
    El Refai, Ahmed
    Abed, Farid
    JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2016, 20 (04)
  • [39] A Study of the Shear Behavior of Concrete Beams with Synthetic Fibers Reinforced with Glass and Basalt Fiber-Reinforced Polymer Bars
    Duarte, Isabela Oliveira
    Forti, Nadia Cazarim da Silva
    Pimentel, Lia Lorena
    Jacintho, Ana Elisabete Paganelli Guimaraes de Avila
    BUILDINGS, 2024, 14 (07)
  • [40] Bond Performance between Fiber-Wrapped Ribbed Basalt Fiber-Reinforced Polymer Bars and Seawater Sea-Sand Concrete
    Lin, Min
    Weng, Chenyue
    Xiao, Hesheng
    Zeng, Dong
    Zhang, Baifa
    Chen, Xiaopan
    He, Shaohua
    Li, Lijuan
    BUILDINGS, 2024, 14 (01)