Bullet characterization using Photon-Counting detector CT: A phantom with intact bullets

被引:0
|
作者
Hardy, Joey C. A. [1 ]
Crombag, Genevieve A. J. C. [1 ,2 ]
Peters, Nicky H. G. M. [1 ]
Hermsen, Rob [3 ]
Willigers, Jef L. [1 ]
Nobel, J. Martijn [1 ,2 ,4 ]
Wildberger, Joachim E. [1 ,5 ]
Flohr, Thomas G. [1 ,6 ]
Postma, Alida A. [1 ,7 ]
机构
[1] Maastricht Univ, Dept Radiol & Nucl Med, Med Ctr, POB 5000, NL-6202 AZ Maastricht, Netherlands
[2] Maastricht Univ, Care & Publ Hlth Res Inst CAPHRI, Med Ctr, POB 616, NL-6200 MD Maastricht, Netherlands
[3] Netherlands Forens Inst, POB 24044, NL-2490 AA The Hague, Netherlands
[4] Maastricht Univ, GROW Sch Oncol & Reprod, Med Ctr, POB 616, NL-6200 MD Maastricht, Netherlands
[5] Maastricht Univ, Cardiovasc Res Inst Maastricht CARIM, POB 616, NL-6200 MD Maastricht, Netherlands
[6] Siemens Healthineers AG, Siemensstr 3, D-91301 Forchheim, Germany
[7] Maastricht Univ, Mental Hlth & Sci MHaNa Res Inst, POB 616, NL-6200 MD Maastricht, Netherlands
关键词
Photon-counting detector CT; PCD-CT; Dual-energy ratio; UHR; Forensic Radiology; Criminal investigation; Bullet; COMPUTED-TOMOGRAPHY;
D O I
10.1016/j.ejrad.2024.111898
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVES: Photon-counting detector CT (PCD-CT) is expected to substantially improve and expand CTimaging applicability due to its intrinsic spectral capabilities, increased spatial resolution, reduced electronic noise, and improved image contrast. The current study aim is to evaluate PCD-CT efficacy in characterizing bullets based on their dimensions, shape, and material composition. MATERIALS AND METHODS: This is an observational phantom study examining 11 unfired, intact bullets of various common calibers, placed in ballistic gelatin. Ultra-high resolution and spectral images were acquired on a clinical PCD-CT-scanner. CT-measurements of the dimensions (length and diameter) were independently determined by 2 readers and compared to previously obtained manual caliper measurements. Bullet shape (round nose, flat nose, or spitzer bullet) was assessed using 3D-volume rendered (3D-VR) CT-image reconstruction. Bullet composition was examined based on dual-energy ratios (DER) which were color-coded accordingly and overlaid on high resolution CT-images. RESULTS: Compared to caliper measurements, mean differences (SD) in bullet diameter were + 0.40 mm (0.16) and + 0.38 mm (0.13) for readers 1 and 2; mean differences in length were + 0.49 mm (0.19) and + 0.45 mm (0.20). The observed proportion of accurately categorized 3D-VR reconstructions was 90.9 % (10/11) for both readers with moderate interrater agreement (Cohens kappa: 0.59, P = 0.004). DER color-coded images showed clear distinction between jacket and core and enabled correct identification of bullets with and without jackets. CONCLUSIONS: These results indicate that PCD-CT is a promising tool for reliable radiological characterization of bullets.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] Evaluation of the ear ossicles with photon-counting detector CT
    Yuka Takahashi
    Fumiyo Higaki
    Akiko Sugaya
    Yudai Asano
    Katsuhide Kojima
    Yusuke Morimitsu
    Noriaki Akagi
    Toshihide Itoh
    Yusuke Matsui
    Takao Hiraki
    Japanese Journal of Radiology, 2024, 42 : 158 - 164
  • [22] Multicolour imaging with spectral photon-counting CT: a phantom study
    Si-Mohamed S.
    Bar-Ness D.
    Sigovan M.
    Tatard-Leitman V.
    Cormode D.P.
    Naha P.C.
    Coulon P.
    Rascle L.
    Roessl E.
    Rokni M.
    Altman A.
    Yagil Y.
    Boussel L.
    Douek P.
    European Radiology Experimental, 2 (1)
  • [23] Phantom study of layered sensor module for photon-counting BMD detector
    Jangwon Byun
    Yonghoon Kim
    Jiwon Seo
    Eunhye Kim
    Kihyun Kim
    Ajin Jo
    Wonho Lee
    Hyun Woo Cho
    Jichul Seo
    Beomjun Park
    Physical and Engineering Sciences in Medicine, 2023, 46 : 1553 - 1562
  • [24] Using Dual-source Photon-counting Detector CT to Simultaneously Quantify Fat and Iron Content: A Phantom Study
    Hao, Wanting
    Xu, Zhihan
    Lin, Huimin
    Yan, Fuhua
    ACADEMIC RADIOLOGY, 2024, 31 (10) : 4119 - 4128
  • [25] Phantom study of layered sensor module for photon-counting BMD detector
    Byun, Jangwon
    Kim, Yonghoon
    Seo, Jiwon
    Kim, Eunhye
    Kim, Kihyun
    Jo, Ajin
    Lee, Wonho
    Cho, Hyun Woo
    Seo, Jichul
    Park, Beomjun
    PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2023, 46 (04) : 1553 - 1562
  • [26] Photon-Counting Detector CT-Based Vascular Calcium Removal Algorithm Assessment Using a Cardiac Motion Phantom
    Allmendinger, Thomas
    Nowak, Tristan
    Flohr, Thomas
    Klotz, Ernst
    Hagenauer, Junia
    Alkadhi, Hatem
    Schmidt, Bernhard
    INVESTIGATIVE RADIOLOGY, 2022, 57 (06) : 399 - 405
  • [27] Phantom-based radiomics feature test–retest stability analysis on photon-counting detector CT
    Alexander Hertel
    Hishan Tharmaseelan
    Lukas T. Rotkopf
    Dominik Nörenberg
    Philipp Riffel
    Konstantin Nikolaou
    Jakob Weiss
    Fabian Bamberg
    Stefan O. Schoenberg
    Matthias F. Froelich
    Isabelle Ayx
    European Radiology, 2023, 33 : 4905 - 4914
  • [28] Stability and accuracy of fat quantification on photon-counting detector CT with various scan settings: A phantom study
    Zhang, Xu
    Bao, Shouyu
    Wang, Mengzhen
    Xu, Zhihan
    Yan, Fuhua
    Yang, Wenjie
    EUROPEAN JOURNAL OF RADIOLOGY, 2024, 177
  • [29] Lesion Detectability and Radiation Dose in Spiral Breast CT With Photon-Counting Detector Technology A Phantom Study
    Shim, Sojin
    Saltybaeva, Natalia
    Berger, Nicole
    Marcon, Magda
    Alkadhi, Hatem
    Boss, Andreas
    INVESTIGATIVE RADIOLOGY, 2020, 55 (08) : 515 - 523
  • [30] Robustness of radiomics among photon-counting detector CT and dual-energy CT systems: a texture phantom study
    Zhu, Lan
    Dong, Haipeng
    Sun, Jing
    Wang, Lingyun
    Xing, Yue
    Hu, Yangfan
    Lu, Junjie
    Yang, Jiarui
    Chu, Jingshen
    Yan, Chao
    Yuan, Fei
    Zhong, Jingyu
    EUROPEAN RADIOLOGY, 2025, 35 (02) : 871 - 884