Bullet characterization using Photon-Counting detector CT: A phantom with intact bullets

被引:0
|
作者
Hardy, Joey C. A. [1 ]
Crombag, Genevieve A. J. C. [1 ,2 ]
Peters, Nicky H. G. M. [1 ]
Hermsen, Rob [3 ]
Willigers, Jef L. [1 ]
Nobel, J. Martijn [1 ,2 ,4 ]
Wildberger, Joachim E. [1 ,5 ]
Flohr, Thomas G. [1 ,6 ]
Postma, Alida A. [1 ,7 ]
机构
[1] Maastricht Univ, Dept Radiol & Nucl Med, Med Ctr, POB 5000, NL-6202 AZ Maastricht, Netherlands
[2] Maastricht Univ, Care & Publ Hlth Res Inst CAPHRI, Med Ctr, POB 616, NL-6200 MD Maastricht, Netherlands
[3] Netherlands Forens Inst, POB 24044, NL-2490 AA The Hague, Netherlands
[4] Maastricht Univ, GROW Sch Oncol & Reprod, Med Ctr, POB 616, NL-6200 MD Maastricht, Netherlands
[5] Maastricht Univ, Cardiovasc Res Inst Maastricht CARIM, POB 616, NL-6200 MD Maastricht, Netherlands
[6] Siemens Healthineers AG, Siemensstr 3, D-91301 Forchheim, Germany
[7] Maastricht Univ, Mental Hlth & Sci MHaNa Res Inst, POB 616, NL-6200 MD Maastricht, Netherlands
关键词
Photon-counting detector CT; PCD-CT; Dual-energy ratio; UHR; Forensic Radiology; Criminal investigation; Bullet; COMPUTED-TOMOGRAPHY;
D O I
10.1016/j.ejrad.2024.111898
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVES: Photon-counting detector CT (PCD-CT) is expected to substantially improve and expand CTimaging applicability due to its intrinsic spectral capabilities, increased spatial resolution, reduced electronic noise, and improved image contrast. The current study aim is to evaluate PCD-CT efficacy in characterizing bullets based on their dimensions, shape, and material composition. MATERIALS AND METHODS: This is an observational phantom study examining 11 unfired, intact bullets of various common calibers, placed in ballistic gelatin. Ultra-high resolution and spectral images were acquired on a clinical PCD-CT-scanner. CT-measurements of the dimensions (length and diameter) were independently determined by 2 readers and compared to previously obtained manual caliper measurements. Bullet shape (round nose, flat nose, or spitzer bullet) was assessed using 3D-volume rendered (3D-VR) CT-image reconstruction. Bullet composition was examined based on dual-energy ratios (DER) which were color-coded accordingly and overlaid on high resolution CT-images. RESULTS: Compared to caliper measurements, mean differences (SD) in bullet diameter were + 0.40 mm (0.16) and + 0.38 mm (0.13) for readers 1 and 2; mean differences in length were + 0.49 mm (0.19) and + 0.45 mm (0.20). The observed proportion of accurately categorized 3D-VR reconstructions was 90.9 % (10/11) for both readers with moderate interrater agreement (Cohens kappa: 0.59, P = 0.004). DER color-coded images showed clear distinction between jacket and core and enabled correct identification of bullets with and without jackets. CONCLUSIONS: These results indicate that PCD-CT is a promising tool for reliable radiological characterization of bullets.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Photon-Counting Detector CT
    Marth, Adrian A.
    Goller, Sophia S.
    Kajdi, Georg W.
    Marcus, Roy P.
    Sutter, Reto
    INVESTIGATIVE RADIOLOGY, 2024, 59 (08) : 545 - 553
  • [2] Discrimination of Hemorrhage and Contrast Media in a Head Phantom on Photon-Counting Detector CT Data
    Risch, Franka
    Berlis, Ansgar
    Kroencke, Thomas
    Schwarz, Florian
    Maurer, Christoph J.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2024, 45 (02) : 183 - 187
  • [3] The technical development of photon-counting detector CT
    Cynthia H. McCollough
    Kishore Rajendran
    Shuai Leng
    Lifeng Yu
    Joel G. Fletcher
    Karl Stierstorfer
    Thomas G. Flohr
    European Radiology, 2023, 33 : 5321 - 5330
  • [4] The technical development of photon-counting detector CT
    McCollough, Cynthia H.
    Rajendran, Kishore
    Leng, Shuai
    Yu, Lifeng
    Fletcher, Joel G.
    Stierstorfer, Karl
    Flohr, Thomas G.
    EUROPEAN RADIOLOGY, 2023, 33 (08) : 5321 - 5330
  • [5] AJR Forum on Photon-Counting Detector CT
    Dane, Bari
    Amrhein, Timothy J.
    Kay, Fernando
    Schwartz, Fides R.
    Toia, Giuseppe V.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2024, 223 (06)
  • [6] The Future Arrived Photon-Counting Detector CT
    Alkadhi, Hatem
    Runge, Val
    INVESTIGATIVE RADIOLOGY, 2023, 58 (07) : 439 - 440
  • [7] Advanced Neuroimaging With Photon-Counting Detector CT
    Abel, Frederik
    Schubert, Tilman
    Winklhofer, Sebastian
    INVESTIGATIVE RADIOLOGY, 2023, 58 (07) : 472 - 481
  • [8] Pediatric Applications of Photon-Counting Detector CT
    Cao, Joseph
    Bache, Steve
    Schwartz, Fides R.
    Frush, Donald
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2023, 220 (04) : 580 - 589
  • [9] Characterization of a GaAs photon-counting detector for mammography
    Ghammraoui, Bahaa
    Gkoumas, Spyridon
    Glick, Stephen J.
    JOURNAL OF MEDICAL IMAGING, 2021, 8 (03)
  • [10] An introduction to photon-counting detector CT (PCD CT) for radiologists
    Nakamura, Yuko
    Higaki, Toru
    Kondo, Shota
    Kawashita, Ikuo
    Takahashi, Isao
    Awai, Kazuo
    JAPANESE JOURNAL OF RADIOLOGY, 2023, 41 (03) : 266 - 282