Comparison of radial immunodiffusion, turbidimetric immunoassay, and Brix refractometry for determining bovine colostrum quality

被引:1
|
作者
Westhoff, T. A. [1 ]
Behling-Kelly, E. L. [1 ]
Mann, S. [1 ]
机构
[1] Cornell Univ, Coll Vet Med, Dept Populat Med & Diagnost Sci, Ithaca, NY 14853 USA
来源
JDS COMMUNICATIONS | 2024年 / 5卷 / 06期
基金
美国食品与农业研究所;
关键词
IMMUNOGLOBULIN-G CONCENTRATION; IMMUNOTURBIDIMETRY; ACCURACY; IGG;
D O I
10.3168/jdsc.2024-0604
中图分类号
S8 [畜牧、 动物医学、狩猎、蚕、蜂];
学科分类号
0905 ;
摘要
Determining the concentration of IgG in colostrum is critical for assessment of colostrum quality. On-farm use of a Brix refractometer to estimate colostrum IgG concentration is widespread, whereas radial immunodiffusion (RID) is the laboratory reference method. Turbidimetric immunoassay (TIA) might offer an alternative method to quantify IgG in colostrum, but the agreement with RID, as well as critical thresholds to determine high-quality colostrum, remain uncertain. The objective of this study was to determine the level of agreement between RID, Brix %, and TIA for evaluation of colostrum quality. Composite colostrum samples (n = 58) from Holstein cows were evaluated using a digital Brix refractometer at the time of collection and stored at -20 degrees C until analysis. The concentration of IgG was determined using RID and TIA. Data were analyzed using Passing-Bablok regression and Bland-Altman plots. Critical thresholds for TIA and Brix measurements to identify colostrum with an IgG concentration >= 50 and >= 100 g/L based on the reference method were determined using logistic regression and receiver operating characteristic curves. Results revealed that both TIA (Kendall's'r = 0.91) and Brix % ('r = 0.78) had a strong correlation with RID. Passing-Bablok regression identified a systematic (6.91 [4.33 to 8.98] g/L) and proportional (0.69 [0.67 to 0.72] g/L) bias between RID and TIA. The optimum thresholds to identify samples with an IgG concentration >= 50 and >= 100 g/L were 40.6 g/L (area under the curve [AUC]: 1.0; sensitivity (Se): 100; specificity [Sp]: 100) and 85.8 g/L (AUC: 0.99; Se: 96.6; Sp: 96.6) for TIA and 18.4% (AUC: 1.0; Se: 100; Sp: 100) and 25.8% (AUC: 0.99; Se: 82.8; Sp: 93.1) for Brix %, respectively. Using the identified thresholds, our results show that both Brix and TIA were highly accurate for identifying high-quality colostrum, but because of a proportional bias, direct comparison of IgG concentration results obtained by RID and TIA are cautioned.
引用
收藏
页数:6
相关论文
共 27 条
  • [21] Comparison of two commercial radial immunodiffusion assays for detection of bovine immunoglobulin G in newborn calves
    Ameri, Mehrdad
    Wilkerson, Melinda J.
    JOURNAL OF VETERINARY DIAGNOSTIC INVESTIGATION, 2008, 20 (03) : 333 - 336
  • [22] ASSESSMENT OF NEW RADIOIMMUNOASSAY KIT FOR DETERMINING URINARY ALBUMIN AT LOW CONCENTRATIONS - COMPARISON WITH RADIAL IMMUNODIFFUSION
    WATTS, GF
    ALBANO, JDM
    BENNETT, JE
    MORRIS, RW
    SHAW, KM
    POLAK, A
    JOURNAL OF CLINICAL PATHOLOGY, 1986, 39 (10) : 1151 - 1154
  • [23] A COMPARISON OF THE IMMUNODIFFUSION TEST, THE NEUTRALIZATION TEST AND ENZYME-IMMUNOASSAY FOR THE DETECTION OF ANTIBODIES TO INFECTIOUS BOVINE-RHINOTRACHEITIS
    SPIECK, M
    WOERNLE, H
    TIERARZTLICHE UMSCHAU, 1986, 41 (12): : 958 - 965
  • [24] QUANTITATION OF BOVINE IMMUNOGLOBULINS - COMPARISON OF SINGLE RADIAL IMMUNODIFFUSION, ZINC-SULFATE TURBIDITY, SERUM ELECTROPHORESIS, AND REFRACTOMETER METHODS
    PFEIFFER, NE
    MCGUIRE, TC
    BENDEL, RB
    WEIKEL, JM
    AMERICAN JOURNAL OF VETERINARY RESEARCH, 1977, 38 (05) : 693 - 698
  • [25] Diagnostic utility of measuring serum amyloid A with a latex agglutination turbidimetric immunoassay in bovine mastitis: Comparison with haptoglobin and alpha 1 acid glycoprotein
    Otsuka, Marina
    Sugiyama, Mieko
    Ito, Takaaki
    Tsukano, Kenji
    Oikawa, Shin
    Suzuki, Kazuyuki
    JOURNAL OF VETERINARY MEDICAL SCIENCE, 2021, 83 (02): : 329 - 332
  • [26] A COMPETITIVE ENZYME-IMMUNOASSAY SUBCLASS((R)) FOR THE DETERMINATION OF TOTAL IGG-SUBCLASS LEVELS IN HUMAN SERUM - COMPARISON WITH SINGLE RADIAL IMMUNODIFFUSION
    MARANON, F
    CASANOVAS, M
    BERRENS, L
    OLLES, JM
    DIEGUEZ, MA
    JOURNAL OF IMMUNOASSAY, 1994, 15 (02): : 147 - 156
  • [27] MEASUREMENT OF NEONATAL EQUINE IMMUNOGLOBULINS FOR ASSESSMENT OF COLOSTRAL IMMUNOGLOBULIN TRANSFER - COMPARISON OF SINGLE RADIAL IMMUNODIFFUSION WITH ZINC-SULFATE TURBIDITY TEST, SERUM ELECTROPHORESIS, REFRACTOMETRY FOR TOTAL SERUM-PROTEIN, AND SODIUM-SULFITE PRECIPITATION TEST
    RUMBAUGH, GE
    ARDANS, AA
    GINNO, D
    TROMMERSHAUSENSMITH, A
    JOURNAL OF THE AMERICAN VETERINARY MEDICAL ASSOCIATION, 1978, 172 (03): : 321 - 324