Sensitivity-enhanced temperature sensor with parallel dual fabry-perot interferometers structure based on harmonic Vernier effect

被引:0
|
作者
Zuo, Cheng [1 ,2 ,3 ]
Wu, Kaiyang [1 ,2 ,3 ]
Luo, Jiatong [4 ]
Guang, Dong [1 ,2 ,3 ]
Zhu, Jun [1 ,2 ,3 ]
Wu, Xuqiang [1 ,2 ,3 ]
Shi, Jinhui [1 ,2 ]
Yu, Benli [1 ,2 ,3 ]
机构
[1] Anhui Univ, Informat Mat & Intelligent Sensing Lab Anhui Prov, Hefei 230601, Peoples R China
[2] Anhui Univ, Key Lab Optoelect Informat Acquisit & Manipulat, Minist Educ, Hefei 230601, Peoples R China
[3] Anhui Univ, Sch Phys & Optoelect Engn, Hefei 230601, Peoples R China
[4] Anhui Zhibo Optoelect Technol Co Ltd, Chuangxin Blvd 2800, Hefei 230088, Peoples R China
关键词
Temperature sensor; Harmonic vernier effect; Fabry-perot interferometer; Polarization maintaining photonic crystal fiber; FIBER SENSOR;
D O I
10.1016/j.optcom.2024.131363
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
A sensitivity-enhanced temperature sensor with a parallel dual Fabry-Perot interferometers (FPIs) structure based on the harmonic Vernier effect is proposed and experimentally demonstrated. The sensing FPI is fabricated by fusion splicing a multi-hundred-micron long polarization maintaining photonic crystal fiber (PMPCF) tip with a single mode fiber (SMF). The reference FPI is fabricated by inserting two SMFs into the ends of a single-pore capillary. The length of the air cavity in the reference FPI is controlled and optimized to create a harmonic Vernier effect, thereby achieving significant sensitization of the sensor sensitivity and modulation of the amplification factor. Experimental results show that the temperature sensitivity of the single sensing FPI is 11.9 p.m./degrees C from 40 degrees C to 400 degrees C, and the temperature sensitivities of the parallel dual FPIs based on the harmonic Vernier effect are-408.95 p.m./degrees C,-723.23 p.m./degrees C, and-1.93 nm/degrees C, respectively. The proposed sensor has a simple structure, high sensitivity, and excellent stability, making it have certain application prospects in high temperature measurement fields such as aerospace and metallurgy.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Sensitivity-enhanced temperature sensor with cascaded fiber optic Sagnac interferometers based on Vernier-effect
    Shao, Li-Yang
    Luo, Yuan
    Zhang, Zhiyong
    Zou, Xihua
    Luo, Bin
    Pan, Wei
    Yan, Lianshan
    OPTICS COMMUNICATIONS, 2015, 336 : 73 - 76
  • [32] A Sensitivity-Enhanced Fiber Optic Fabry-Perot Acoustic Sensor Based on Grooved Diaphragm
    Niu, Xiling
    Huang, Yi
    Zhang, Lina
    Wang, Liangjie
    Hu, Chengyong
    Deng, Chuanlu
    Wu, Peng
    Lu, Yuncai
    Li, Qun
    Zhang, Qi
    Zhang, Xiaobei
    Wang, Tingyun
    IEEE PHOTONICS TECHNOLOGY LETTERS, 2023, 35 (08) : 422 - 425
  • [33] Fabry-Perot Temperature Sensor Based on Virtual Vernier Sensitization
    Zhang, Cheng
    Ma, Xuehui
    Zhao, Junfa
    Shen, Zhenqian
    Wu, Jixuan
    Yang, Jing
    CHINESE JOURNAL OF LASERS-ZHONGGUO JIGUANG, 2023, 50 (13):
  • [34] Simultaneous temperature and bending sensor based on Fabry-Perot interferometer with Vernier effect
    Zhang, Shaoxian
    Zhou, Ai
    Yuan, Libo
    OPTICAL FIBER TECHNOLOGY, 2021, 66
  • [35] Ultra-sensitive relative humidity sensor formed by two parallel Fabry-Perot interferometers and Vernier effect
    Shu, Yukun
    Jiang, Chao
    Deng, Longfeng
    Hu, Chuanju
    Gao, Jiawei
    Li, Li
    Li, Hong
    Sun, Simei
    INFRARED PHYSICS & TECHNOLOGY, 2024, 137
  • [36] High-sensitivity fiber temperature and pressure sensor based on fabry-perot interferometry and Vernier effect
    Ma, Chaoqun
    Chen, Yanxia
    Qu, Wenwen
    Peng, Donghong
    Bai, Xuanyao
    Liu, Shuangqiang
    Luo, Le
    OPTICS AND LASER TECHNOLOGY, 2025, 181
  • [37] High sensitivity temperature and pressure sensor based on cascaded Fabry-Perot and Sagnac interferometers
    Chen, Hai-lin
    Zhu, Xi-ping
    Jiang, Chao
    Li, Hong
    Guo, Xiao-shan
    Sun, Si-mei
    INSTRUMENTATION SCIENCE & TECHNOLOGY, 2022, 50 (04) : 422 - 436
  • [38] High sensitivity temperature and pressure sensor based on cascaded Fabry-Perot and Sagnac interferometers
    Chen, Hai-lin
    Zhu, Xi-ping
    Jiang, Chao
    Li, Hong
    Guo, Xiao-shan
    Sun, Si-mei
    Instrumentation Science and Technology, 2022, 50 (04): : 422 - 436
  • [39] High-sensitivity gas pressure sensor with low temperature cross-talk based on Vernier effect of cascaded Fabry-Perot interferometers
    Tian, Peixuan
    Guan, Chunying
    Xiong, Ziyang
    Gao, Shan
    Ye, Peng
    Yang, Jing
    He, Xuelan
    Shi, Jinhui
    Yuan, Libo
    OPTICAL FIBER TECHNOLOGY, 2023, 75
  • [40] Multiparameter Sensing of the Vernier Effect Based on Cascaded Sagnac and Fabry-Perot Interferometers
    Cheng, Ao
    Wang, Chaoqi
    Xu, Jiadong
    Dai, Shixun
    Zheng, Yu
    IEEE SENSORS JOURNAL, 2024, 24 (12) : 19090 - 19097