Direct detection of doxorubicin in whole blood using a hydrogel-protected electrochemical aptamer-based biosensor

被引:1
|
作者
Luo, Songjia [1 ]
Wu, Qingliu [1 ]
Wang, Lu [1 ,2 ]
Qu, Hao [1 ,3 ]
Zheng, Lei [1 ,4 ]
机构
[1] Hefei Univ Technol, Sch Food & Biol Engn, Hefei 230009, Peoples R China
[2] Hefei Univ Technol, Engn Res Ctr Bioproc, Minist Educ, Hefei 230009, Peoples R China
[3] Anhui Prov Int Sci & Technol Cooperat Base Major M, Hefei 230009, Peoples R China
[4] Hefei Univ Technol, Intelligent Interconnected Syst Lab Anhui Prov, Hefei 230009, Peoples R China
基金
中国国家自然科学基金;
关键词
Hydrogel; Electrochemical aptamer-based biosensor; Doxorubicin detection; Whole blood; Anti-biofouling; PLATFORM; GRAPHENE;
D O I
10.1016/j.talanta.2024.127289
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Electrochemical aptamer-based biosensors (EABs) have been developed for multiple important biomarkers for their convenient and real-time features. However, the application of EABs in complex biological fluids has been limited by the rapid loss of sensitivity and selectivity due to inactivation and biofouling of aptamer probes and electrodes. To address this issue, we report the preparation of a simple hydrogel-protected aptamer-based biosensor (HP-EAB) for direct detection of Doxorubicin (DOX) in whole blood. The aptamer provides excellent selectivity for the electrochemical sensor, allowing the prepared sensor to accurately detect DOX in a 50-fold diluted whole blood sample. The agarose hydrogel coating on the electrode surface allows the passage of small molecules while hindering the adsorption of biomolecules from the whole blood matrix to the electrode surface. The experimental results show that the prepared HP-EAB has high stability compared with the unprotected EAB, and the HP-EAB maintains excellent detection performance after 7 days of storage. The hydrogel coating can effectively reduce the non-specific response to the whole blood matrix and prolong the life-time of the sensor. When used to detect DOX in rabbit whole blood, the HP-EAB exhibited excellent detection performance with a detection limit of 25.9 nM (S/N = 3) and a detection range of 0.1 mu M-50 mu M. The developed HPEAB provides an excellent platform for the rapid and accurate determination of important analytes in complex biological fluids.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] DNA aptamer-based sensitive electrochemical biosensor for NAD (H) detection
    Guo, Wenfei
    Wang, Haiyuan
    Wang, Zhaoyang
    Wu, Fandi
    He, Yao
    Liu, Yuan
    Deng, Yan
    Bing, Tao
    Qiu, Liping
    Tan, Weihong
    BIOSENSORS & BIOELECTRONICS, 2025, 271
  • [22] An RNA aptamer-based electrochemical biosensor for sensitive detection of malachite green
    Wang, Hongzhi
    Wang, Yu
    Liu, Su
    Yu, Jinghua
    Xu, Wei
    Guo, Yuna
    Huang, Jiadong
    RSC ADVANCES, 2014, 4 (105): : 60987 - 60994
  • [23] A Rapid and Sensitive Aptamer-Based Electrochemical Biosensor for Direct Detection of Escherichia Coli O111
    Luo, Caihui
    Lei, Yaning
    Yan, Li
    Yu, Tianxiao
    Li, Qing
    Zhang, Decai
    Ding, Shijia
    Ju, Huangxian
    ELECTROANALYSIS, 2012, 24 (05) : 1186 - 1191
  • [24] Detection of kanamycin by using an aptamer-based biosensor using silica nanoparticles
    Khabbaz, Ladan Saadat
    Hassanzadeh-Khayyat, Mohammad
    Zaree, Pouya
    Ramezani, Mohammad
    Abnous, Khalil
    Taghdisi, Seyed Mohammad
    ANALYTICAL METHODS, 2015, 7 (20) : 8611 - 8616
  • [25] Colorimetric Detection of Hemoglobin by Aptamer-Based Biosensor
    Teniou, Ahlem
    Rhouati, Amina
    Madi, Ibrahim Alaa Eddine
    Mouhoub, Riane
    Catanante, Gaelle
    Mashifana, Tebogo
    Vasseghian, Yasser
    Berkani, Mohammed
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2023, 62 (11) : 4704 - 4712
  • [26] An aptamer-based biosensor for sensitive thrombin detection
    Yang, Hui
    Ji, Ji
    Liu, Yun
    Kong, Jilie
    Liu, Baohong
    ELECTROCHEMISTRY COMMUNICATIONS, 2009, 11 (01) : 38 - 40
  • [27] An aptamer-based electrochemiluminescent biosensor for ATP detection
    Yao, Wu
    Wang, Lun
    Wang, Haiyan
    Zhang, Xiaolei
    Li, Ling
    BIOSENSORS & BIOELECTRONICS, 2009, 24 (11): : 3269 - 3274
  • [28] Application of Aptamer-based Biosensor in Bisphenol A Detection
    Huang, Lei
    Wang, Xin
    Liu, Sha
    Gao, Zhi-Xian
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2021, 49 (02) : 172 - 183
  • [29] A multivalent aptamer-based electrochemical biosensor for biomarker detection in urinary tract infection
    Naseri, Maryam
    Halder, Arnab
    Mohammadniaei, Mohsen
    Prado, Marta
    Ashley, Jon
    Sun, Yi
    ELECTROCHIMICA ACTA, 2021, 389
  • [30] A Disposable Electrochemical Sensor for the Direct Detection of Doxorubicin in Whole Blood
    Wang, Shi
    Huang, Ziwei
    Liu, Min
    Ding, Hong
    SENSOR LETTERS, 2012, 10 (1-2) : 117 - 121