Accuracy and precision of non-invasive thermometers compared with the pulmonary artery temperature: a cross-sectional study

被引:0
|
作者
de Carvalho, Rafael Lima Rodrigues [1 ,2 ]
Victoriano, Mariana Avendanha [1 ,3 ]
Campos, Camila Claudia [1 ,4 ]
Vassallo, Paula Frizera [1 ,5 ]
Nobre, Vandack [1 ,6 ]
Ercole, Flavia Falci [1 ,7 ]
机构
[1] Univ Fed Minas Gerais, Belo Horizonte, MG, Brazil
[2] Univ Fed Bahia UFBA, Nursing Sch, Salvador, BA, Brazil
[3] Proz Educ, Sao Paulo, SP, Brazil
[4] Fac Anhanguera, Belo Horizonte, MG, Brazil
[5] Univ Fed Minas Gerais UFMG, Hosp Clin, Gen Intens Therapy, Belo Horizonte, MG, Brazil
[6] Univ Fed Minas Gerais UFMG, Med Sch, Belo Horizonte, MG, Brazil
[7] Univ Fed Minas Gerais UFMG, Sch Nursing, Belo Horizonte, MG, Brazil
来源
SAO PAULO MEDICAL JOURNAL | 2024年 / 142卷 / 06期
关键词
Thermometers; Fever; Temporal Arteries; CORE TEMPERATURE; THERAPEUTIC HYPOTHERMIA;
D O I
10.1590/1516-3180.2023.0409.R1.05062024
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: Temperature fluctuations are critical indicators of a patient's condition in intensive care units (ICUs). While invasive methods offer a more reliable measurement of core temperature, they carry greater risks of complications, limiting their use in most situations. This underscores the need for research evaluating the reliability of non-invasive temperature monitoring methods. OBJECTIVES: This study aimed to assess the accuracy and precision of four non-invasive temperature measurement techniques compared to pulmonary artery temperature, considered the gold standard. DESIGN AND SETTING: We conducted a cross-sectional clinical study with repeated measures in the ICUs at Hospital das Cl & iacute;nicas da Universidade Federal de Minas Gerais and Hospital Fel & iacute;cio Rocho, Belo Horizonte, Brazil. METHODS: All patients admitted with a pulmonary artery catheter were included. We simultaneously recorded temperatures from the pulmonary artery, axillary area, oral cavity, temporal artery, and tympanic membrane. Bland-Altman plots were employed to assess the agreement between the different temperature measurements. RESULTS: A total of 48 patients participated, with a mean age of 54 years. Females comprised 66.67% of the sample. Compared to pulmonary artery temperature, the accuracy and precision (mean and standard deviation) of the non-invasive methods were: axillary (-0.42 degrees C, 0.59 degrees C), oral (-0.30 degrees C, 0.37 degrees C), tympanic membrane (-0.21 degrees C, 0.44 degrees C), and temporal artery (-0.25 degrees C, 0.61 degrees C). Notably, in patients with abnormal body temperature (non-normothermic), only oral and tympanic membrane methods maintained their accuracy and precision. CONCLUSIONS: The non-invasive thermometers evaluated in this study demonstrated acceptable accuracy and precision (within the clinically relevant threshold of 0.5 degrees C) compared to pulmonary artery temperature. Among the non-invasive methods, the tympanic membrane measurement proved to be the most reliable, followed by the oral method.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] Comparison of conventional and non-invasive diagnostic tools for detecting Plasmodium falciparum infection in southwestern Cameroon: a cross-sectional study
    Apinjoh, Tobias O.
    Ntasin, Veronica N.
    Tataw, Phil Collins C.
    Ntui, Vincent N.
    Njimoh, Dieudonne L.
    Cho-Ngwa, Fidelis
    Achidi, Eric A.
    INFECTIOUS DISEASES OF POVERTY, 2021, 10 (01)
  • [42] Precision of non-invasive temperature measurement by diffuse reflectance spectroscopy
    Wang, ZZ
    Kwan, SL
    Pearsall, TP
    Booth, J
    Beard, BT
    Johnson, SR
    DIAGNOSTIC TECHNIQUES FOR SEMICONDUCTOR MATERIALS PROCESSING II, 1996, 406 : 69 - 74
  • [43] Non-invasive detection of microvascular changes in a paediatric and adolescent population with type 1 diabetes: a pilot cross-sectional study
    Hosking, Sarah P. M.
    Bhatia, Rani
    Crock, Patricia A.
    Wright, Ian
    Squance, Marline L.
    Reeves, Glenn
    BMC ENDOCRINE DISORDERS, 2013, 13
  • [44] Non-invasive detection of microvascular changes in a paediatric and adolescent population with type 1 diabetes: a pilot cross-sectional study
    Sarah P M Hosking
    Rani Bhatia
    Patricia A Crock
    Ian Wright
    Marline L Squance
    Glenn Reeves
    BMC Endocrine Disorders, 13
  • [45] Knowledge and Attitude Regarding Non-Invasive Prenatal Testing (NIPT) among Women: A Cross-Sectional Study in Saudi Arabia
    Bahkali, Nedaa Mohammed
    Eissa, Ghaida Abdullah
    Shaheen, Abdulaziz Mohammed Bashar
    Sanedi, Abdullah Mohammed
    Bahkali, Duaa Mohammed
    CLINICAL AND EXPERIMENTAL OBSTETRICS & GYNECOLOGY, 2023, 50 (10):
  • [46] Non-Invasive Metabolic and Structural Retinal Markers in Patients with Giant Cell Arteritis and Polymyalgia Rheumatica: A Cross-Sectional Study
    Lowater, Simon J.
    Ellingsen, Torkell J.
    Pedersen, Jens K.
    Wied, Jimmi
    Grauslund, Jakob
    Byg, Keld-Erik
    METABOLITES, 2022, 12 (09)
  • [47] Comparison of conventional and non-invasive diagnostic tools for detecting Plasmodium falciparum infection in southwestern Cameroon: a cross-sectional study
    Tobias O. Apinjoh
    Veronica N. Ntasin
    Phil Collins C. Tataw
    Vincent N. Ntui
    Dieudonne L. Njimoh
    Fidelis Cho-Ngwa
    Eric A. Achidi
    Infectious Diseases of Poverty, 10
  • [48] Improving Accuracy, Precision, and Efficiency in Analysis of Osteon Cross-sectional Shape
    Mears, Chad S.
    Litton, Scott M.
    Phippen, Colton M.
    Langston, Tanner D.
    Keenan, Kendra E.
    Skedros, John G.
    AMERICAN JOURNAL OF PHYSICAL ANTHROPOLOGY, 2015, 156 : 223 - 223
  • [49] NON-INVASIVE STUDY OF THE CAROTID-ARTERY
    BAIRD, RN
    WOODCOCK, JP
    LANCET, 1981, 1 (8218): : 500 - 500
  • [50] Precision and accuracy of measuring finger motion with a depth camera: a cross-sectional study of healthy participants
    Lv, Lulu
    Yang, Jiantao
    Gu, Fanbin
    Fan, Jingyuan
    Zhu, Qingtang
    Liu, Xiaolin
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2023, 48 (05) : 453 - 458