Accuracy and precision of non-invasive thermometers compared with the pulmonary artery temperature: a cross-sectional study

被引:0
|
作者
de Carvalho, Rafael Lima Rodrigues [1 ,2 ]
Victoriano, Mariana Avendanha [1 ,3 ]
Campos, Camila Claudia [1 ,4 ]
Vassallo, Paula Frizera [1 ,5 ]
Nobre, Vandack [1 ,6 ]
Ercole, Flavia Falci [1 ,7 ]
机构
[1] Univ Fed Minas Gerais, Belo Horizonte, MG, Brazil
[2] Univ Fed Bahia UFBA, Nursing Sch, Salvador, BA, Brazil
[3] Proz Educ, Sao Paulo, SP, Brazil
[4] Fac Anhanguera, Belo Horizonte, MG, Brazil
[5] Univ Fed Minas Gerais UFMG, Hosp Clin, Gen Intens Therapy, Belo Horizonte, MG, Brazil
[6] Univ Fed Minas Gerais UFMG, Med Sch, Belo Horizonte, MG, Brazil
[7] Univ Fed Minas Gerais UFMG, Sch Nursing, Belo Horizonte, MG, Brazil
来源
SAO PAULO MEDICAL JOURNAL | 2024年 / 142卷 / 06期
关键词
Thermometers; Fever; Temporal Arteries; CORE TEMPERATURE; THERAPEUTIC HYPOTHERMIA;
D O I
10.1590/1516-3180.2023.0409.R1.05062024
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: Temperature fluctuations are critical indicators of a patient's condition in intensive care units (ICUs). While invasive methods offer a more reliable measurement of core temperature, they carry greater risks of complications, limiting their use in most situations. This underscores the need for research evaluating the reliability of non-invasive temperature monitoring methods. OBJECTIVES: This study aimed to assess the accuracy and precision of four non-invasive temperature measurement techniques compared to pulmonary artery temperature, considered the gold standard. DESIGN AND SETTING: We conducted a cross-sectional clinical study with repeated measures in the ICUs at Hospital das Cl & iacute;nicas da Universidade Federal de Minas Gerais and Hospital Fel & iacute;cio Rocho, Belo Horizonte, Brazil. METHODS: All patients admitted with a pulmonary artery catheter were included. We simultaneously recorded temperatures from the pulmonary artery, axillary area, oral cavity, temporal artery, and tympanic membrane. Bland-Altman plots were employed to assess the agreement between the different temperature measurements. RESULTS: A total of 48 patients participated, with a mean age of 54 years. Females comprised 66.67% of the sample. Compared to pulmonary artery temperature, the accuracy and precision (mean and standard deviation) of the non-invasive methods were: axillary (-0.42 degrees C, 0.59 degrees C), oral (-0.30 degrees C, 0.37 degrees C), tympanic membrane (-0.21 degrees C, 0.44 degrees C), and temporal artery (-0.25 degrees C, 0.61 degrees C). Notably, in patients with abnormal body temperature (non-normothermic), only oral and tympanic membrane methods maintained their accuracy and precision. CONCLUSIONS: The non-invasive thermometers evaluated in this study demonstrated acceptable accuracy and precision (within the clinically relevant threshold of 0.5 degrees C) compared to pulmonary artery temperature. Among the non-invasive methods, the tympanic membrane measurement proved to be the most reliable, followed by the oral method.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] NEW APPROACH TO NON-INVASIVE CORONARY-ARTERY VISUALIZATION USING CROSS-SECTIONAL ECHOCARDIOGRAPHY
    OGAWA, S
    AKAISHI, M
    OHNISHI, S
    MORI, H
    MURAYAMA, A
    AKIZUKI, S
    HOSHINO, T
    NAKAZAWA, H
    HANDA, S
    NAKAMURA, Y
    DREIFUS, LS
    JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION, 1979, 43 (07): : 688 - 688
  • [2] Measurement of non-invasive rectal and ear temperature in inpatients 18 years old: A cross-sectional comparative study
    Jorgensen, Lone
    Boll, Birgitte
    Rosenkilde, Kristina Fischer
    Bruun, Niels Henrik
    Pedersen, Preben Ulrich
    Norgaard, Marianne Wetendorff
    ZEITSCHRIFT FUR EVIDENZ FORTBILDUNG UND QUALITAET IM GESUNDHEITSWESEN, 2025, 192 : 36 - 41
  • [3] Non-invasive assessment of peri-implant mucosal thickness: A cross-sectional study
    Couso-Queiruga, Emilio
    Raabe, Clemens
    Belser, Urs C.
    Buser, Daniel
    Avila-Ortiz, Gustavo
    Rodrigues, Diogo Moreira
    Chappuis, Vivianne
    JOURNAL OF PERIODONTOLOGY, 2023, 94 (11) : 1315 - 1323
  • [4] Diagnostic accuracy of simple tools in monitoring patients with chronic hypoventilation treated with non-invasive ventilation; a prospective cross-sectional study
    Aarrestad, Sigurd
    Qvarfort, Magnus
    Kleiven, Anne Louise
    Tollefsen, Elin
    Skjonsberg, Ole Henning
    Janssens, Jean-Paul
    RESPIRATORY MEDICINE, 2018, 144 : 30 - 35
  • [5] NON-INVASIVE ESTIMATION BY CROSS-SECTIONAL ECHOCARDIOGRAPHY OF MYOCARDIAL DAMAGE IN CARDIOMYOPATHY
    TANAKA, M
    NITTA, S
    NITTA, K
    SOGO, Y
    YAMAMOTO, A
    KATAHIRA, Y
    SATO, N
    OHKAWAI, H
    TEZUKA, F
    BRITISH HEART JOURNAL, 1985, 53 (02): : 137 - 152
  • [6] Helicobacter pylori is no longer a surface colonizing non-invasive pathogen: An observational cross-sectional study
    Samal, Subash Chandra
    Bhat, Sunil Jee
    Panigrahi, Manas Kumar
    Chouhan, Mohd. Imran
    Kumar, Chandan
    Nayak, Hemanta Kumar
    Mishra, Pravin Kumar
    JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2019, 34 : 204 - 204
  • [7] Saliva sample as a non-invasive specimen for the diagnosis of coronavirus disease 2019: a cross-sectional study
    Pasomsub, E.
    Watcharananan, S. P.
    Boonyawat, K.
    Janchompoo, P.
    Wongtabtim, G.
    Suksuwan, W.
    Sungkanuparph, S.
    Phuphuakrat, A.
    CLINICAL MICROBIOLOGY AND INFECTION, 2021, 27 (02) : 285.e1 - 285.e4
  • [8] Non-invasive endothelial function assessment in patients with neurofibromatosis type 1: a cross-sectional study
    Rodrigues, Luiza O.
    Rodrigues, Luiz Oswaldo C.
    Castro, Luisa Lima
    Rezende, Nilton A.
    Ribeiro, Antonio Luiz P.
    BMC CARDIOVASCULAR DISORDERS, 2013, 13
  • [9] Non-invasive endothelial function assessment in patients with neurofibromatosis type 1: a cross-sectional study
    Luiza O Rodrigues
    Luiz Oswaldo C Rodrigues
    Luisa Lima Castro
    Nilton A Rezende
    Antonio Luiz P Ribeiro
    BMC Cardiovascular Disorders, 13
  • [10] Accuracy and precision of a novel non-invasive core thermometer
    Kimberger, O.
    Thell, R.
    Schuh, M.
    Koch, J.
    Sessler, D. I.
    Kurz, A.
    BRITISH JOURNAL OF ANAESTHESIA, 2009, 103 (02) : 226 - 231