The effect of temperature-dependent drug viscosity on needle-free jet injection

被引:1
|
作者
McKeage, James William [1 ]
Full, Hazel Janet [1 ]
Tan, Andrew Zheng Hao [1 ]
Taberner, Andrew James [1 ,2 ]
机构
[1] Univ Auckland, Auckland Bioengn Inst, Auckland, New Zealand
[2] Univ Auckland, Fac Engn, Dept Engn Sci, Auckland, New Zealand
关键词
Jet Injection; Viscosity; Viscous heating; Subcutaneous; Temperature dependence; Biotherapeutics; SUBCUTANEOUS DELIVERY;
D O I
10.1016/j.ijpharm.2024.124777
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Highly viscous drugs cannot be delivered through a needle. Typically, this means that these drugs are formulated at lower concentrations, demanding higher delivery volumes, which often must be delivered intravenously. Jet injection may provide an important solution for viscous drug delivery. Jet injection is a needle-free drug delivery technique whereby a liquid drug is formed into a hair-thin (similar to 200 mu m) high-speed (>100 m/s) jet that penetrates and delivers itself into tissue. While it may seem that it would be just as difficult to form a viscous drug into a high-speed jet as it is to force it down a needle, this is not the case. Recent work has revealed that 'viscous- heating' during jet injection can result in significant temperature increase, and resultant viscosity decrease, in a thin outer-layer of the jet; this phenomenon effectively results in the drug 'self-lubricating' as it passes through a jet injection orifice. Despite the potential for this finding to revolutionise the subcutaneous delivery of high- viscosity drugs, little further work in this area has since been reported on. In this work we develop finite element models of needle-free injection to investigate how viscous heating affects jet production, how heat exchange with the orifice material influences this process, and to what extent jet production is affected by the initial temperature of the fluid. We then conduct novel high-speed measurements of jet and orifice temperature changes due to viscous heating. We find that viscous heating is responsible for approximately doubling the speed of jets that can be produced with very viscous fluid (1 Pa.s) at room temperature. The thermal conductivity of the orifice can transfer heat away from the perimeter of the jet, and thus reduce the lubricating effect of viscous heating. We then show that by preheating 99 % glycerol (1 Pa.s) from 7 degrees C to 37 degrees C the jet speed can be increased 6-fold. We also demonstrate the successful delivery of a very viscous glycerol solution using preheated jet injection into ex vivo porcine tissue. Given that 99 % glycerol is 10- to 100-fold more viscous than current protein therapeutics, our findings demonstrate the potential for jet injection, with or without additional drug preheating, to deliver drug formulations, needle-free, that are much more viscous than those currently delivered through needles.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Needle-free jet injection of intact phospholipid vesicles across the skin: a feasibility study
    Michele Schlich
    Francesco Lai
    Sergio Murgia
    Donatella Valenti
    Anna Maria Fadda
    Chiara Sinico
    Biomedical Microdevices, 2016, 18
  • [32] Design of a Linear Permanent Magnet Transverse Flux Motor for Needle-free Jet Injection
    Do, Nick N. L.
    Taberner, Andrew J.
    Ruddy, Bryan P.
    2019 12TH INTERNATIONAL SYMPOSIUM ON LINEAR DRIVES FOR INDUSTRY APPLICATIONS (LDIA), 2019,
  • [33] Sensorless position control of voice-coil motors for needle-free jet injection
    Mckeage, James W.
    Williams, Rhys M. J.
    Ruddy, Bryan P.
    Nielsen, Poul M. F.
    Taberner, Andrew J.
    PROCEEDINGS OF THE 2015 6TH INTERNATIONAL CONFERENCE ON AUTOMATION, ROBOTICS AND APPLICATIONS (ICARA), 2015, : 426 - 429
  • [34] A Linear Permanent Magnet Synchronous Motor for Large Volume Needle-Free Jet Injection
    Do, Nick N. L.
    Taberner, Andrew James
    Ruddy, Bryan P.
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2019, 55 (02) : 1437 - 1446
  • [35] Needle-free jet injection of intact phospholipid vesicles across the skin: a feasibility study
    Schlich, Michele
    Lai, Francesco
    Murgia, Sergio
    Valenti, Donatella
    Fadda, Anna Maria
    Sinico, Chiara
    BIOMEDICAL MICRODEVICES, 2016, 18 (04)
  • [36] Needle-free jet injection of hyaluronic acid improves skin remodeling in a mouse model
    Kwon, Tae-Rin
    Seok, Joon
    Jang, Ji-Hye
    Kwon, Min Kyung
    Oh, Chang Taek
    Choi, Eun Ja
    Hong, Hyuck Ki
    Choi, Yeon Shik
    Bae, Joonho
    Kim, Beom Joon
    EUROPEAN JOURNAL OF PHARMACEUTICS AND BIOPHARMACEUTICS, 2016, 105 : 69 - 74
  • [37] Conceptualisation of a novel electromechanical system for small-volume needle-free jet injection
    Mohizin, Abdul
    Kim, Jung Kyung
    ENGINEERING APPLICATIONS OF COMPUTATIONAL FLUID MECHANICS, 2023, 17 (01)
  • [38] Dynamic control of needle-free jet injection (vol 135, pg 103, 2009)
    Park, Kinam
    JOURNAL OF CONTROLLED RELEASE, 2009, 138 (01) : 87 - 87
  • [39] EFFECTS OF NOZZLE DIAMETER AND INJECTION VOLUME OF DRUG ON PERFORMANCE OF A NEEDLE-FREE INJECTOR
    Zhu, Yang
    Kang, Can
    Zhang, Chunli
    Li, Haifei
    PROCEEDINGS OF ASME 2021 INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION (IMECE2021), VOL 5, 2021,
  • [40] Drug injection and dispersion characteristics of an air-powered needle-free injector
    Zhu, Yang
    Kang, Can
    Cai, Wei
    Huang, Chao
    MEDICAL ENGINEERING & PHYSICS, 2022, 109