The effect of temperature-dependent drug viscosity on needle-free jet injection

被引:1
|
作者
McKeage, James William [1 ]
Full, Hazel Janet [1 ]
Tan, Andrew Zheng Hao [1 ]
Taberner, Andrew James [1 ,2 ]
机构
[1] Univ Auckland, Auckland Bioengn Inst, Auckland, New Zealand
[2] Univ Auckland, Fac Engn, Dept Engn Sci, Auckland, New Zealand
关键词
Jet Injection; Viscosity; Viscous heating; Subcutaneous; Temperature dependence; Biotherapeutics; SUBCUTANEOUS DELIVERY;
D O I
10.1016/j.ijpharm.2024.124777
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Highly viscous drugs cannot be delivered through a needle. Typically, this means that these drugs are formulated at lower concentrations, demanding higher delivery volumes, which often must be delivered intravenously. Jet injection may provide an important solution for viscous drug delivery. Jet injection is a needle-free drug delivery technique whereby a liquid drug is formed into a hair-thin (similar to 200 mu m) high-speed (>100 m/s) jet that penetrates and delivers itself into tissue. While it may seem that it would be just as difficult to form a viscous drug into a high-speed jet as it is to force it down a needle, this is not the case. Recent work has revealed that 'viscous- heating' during jet injection can result in significant temperature increase, and resultant viscosity decrease, in a thin outer-layer of the jet; this phenomenon effectively results in the drug 'self-lubricating' as it passes through a jet injection orifice. Despite the potential for this finding to revolutionise the subcutaneous delivery of high- viscosity drugs, little further work in this area has since been reported on. In this work we develop finite element models of needle-free injection to investigate how viscous heating affects jet production, how heat exchange with the orifice material influences this process, and to what extent jet production is affected by the initial temperature of the fluid. We then conduct novel high-speed measurements of jet and orifice temperature changes due to viscous heating. We find that viscous heating is responsible for approximately doubling the speed of jets that can be produced with very viscous fluid (1 Pa.s) at room temperature. The thermal conductivity of the orifice can transfer heat away from the perimeter of the jet, and thus reduce the lubricating effect of viscous heating. We then show that by preheating 99 % glycerol (1 Pa.s) from 7 degrees C to 37 degrees C the jet speed can be increased 6-fold. We also demonstrate the successful delivery of a very viscous glycerol solution using preheated jet injection into ex vivo porcine tissue. Given that 99 % glycerol is 10- to 100-fold more viscous than current protein therapeutics, our findings demonstrate the potential for jet injection, with or without additional drug preheating, to deliver drug formulations, needle-free, that are much more viscous than those currently delivered through needles.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Effect of orientation angle for needle-free jet injection
    Lawal, Idera
    Valente, Daniel de Castro Araujo
    Khusnatdinov, Emil
    Elliott, Brian
    Carruth, Breanna
    Penttila, Clayton
    Marston, Jeremy
    INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2024, 664
  • [2] Formulating for Needle-Free Jet Injection
    Challener, Cynthia A.
    BIOPHARM INTERNATIONAL, 2015, 28 (04) : 38 - 41
  • [3] Rotatable Orifice for Needle-Free Jet Injection
    Tan, Andrew Z. H.
    Taberner, Andrew J.
    McKeage, James W.
    2023 45TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY, EMBC, 2023,
  • [4] Dynamic control of needle-free jet injection
    Park, Kinam
    JOURNAL OF CONTROLLED RELEASE, 2009, 135 (02) : 103 - 103
  • [5] Current trends in needle-free jet injection: an update
    Barolet, Daniel
    Benohanian, Antranik
    CLINICAL COSMETIC AND INVESTIGATIONAL DERMATOLOGY, 2018, 11 : 231 - 238
  • [6] Jet injection needle-free dental anaesthesia: Initial findings
    Brunton, Paul A.
    McLean, Mitten
    Vedagiri, Senthilkumar
    McKeage, James
    Ruddy, Bryan
    Weatherly, Kate
    White, David
    Taberner, Andrew
    Loch, Carolina
    JOURNAL OF DENTISTRY, 2022, 122
  • [7] Optimal Voice Coil Actuators for Needle-free Jet Injection
    Ruddy, Bryan P.
    Hunter, Ian W.
    Taberner, Andrew J.
    2014 36TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2014, : 2144 - 2148
  • [8] Effect of injection pressure and fluid volume and density on the jet dispersion pattern of needle-free injection devices
    Grant, Tyler M.
    Stockwell, Kevin D.
    Morrison, Jason B.
    Mann, Danny D.
    BIOSYSTEMS ENGINEERING, 2015, 138 : 59 - 64
  • [9] Needle-free injection technology
    不详
    EXPERT REVIEW OF MEDICAL DEVICES, 2006, 3 (01) : 17 - 17
  • [10] Optimization of Portable Electronically Controlled Needle-Free Jet Injection Systems
    Ruddy, Bryan P.
    Dixon, Alex William
    Williams, Rhys Michael James
    Taberner, Andrew James