Shear Behaviour of V-shape Webbed Steel Fibre Reinforced Concrete Beams

被引:0
|
作者
Visser, Divan [1 ]
Boshoff, William P. [2 ]
机构
[1] Stellenbosch Univ, Stellenbosch, South Africa
[2] Pretoria Univ, Pretoria, South Africa
关键词
Shear capacity; Steel fibres; Fibre reinforced concrete; Self compacting concrete; STRENGTH;
D O I
10.1007/978-3-030-83719-8_42
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Asymmetrical three-point bending tests were performed on beams with four different types of V-shaped/tapered webs (V-beams) containing various percentages of steel fibres by volume (0, 0.6 and 1%) as well as longitudinal reinforcement in the form of two 16 mm diameter steel bars. The test results revealed that the ultimate shear capacity increases significantly with increasing fibre content and larger web cross-sectional areas. The normalised shear stresses at ultimate resistance are relatively constant for the various types of V-beams indicating that shear capacity is highly dependent on the entire cross-sectional area of the web. An average increase in shear strength of 49% for beams containing 0.6% fibres and 74% for beams containing 1% steel fibres was observed for V-beams when compared to their reference beams containing no fibres. Furthermore, the results show that the widely used assumption where shear is resisted entirely by an effective rectangular cross-sectional area calculated as the product of the narrowest part of the beam (bbww) and the effective depth (dd) can result in over-conservative shear predictions for V-beams.
引用
收藏
页码:483 / 491
页数:9
相关论文
共 50 条
  • [31] Shear behaviour of reinforced phyllite concrete beams
    Adom-Asamoah, Mark
    Afrifa, Russell Owusu
    MATERIALS & DESIGN, 2013, 43 : 438 - 446
  • [32] Shear strength model for fibre reinforced polymer shear reinforced concrete beams
    Kang, Su-Min
    Choi, Kyoung-Kyu
    PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-STRUCTURES AND BUILDINGS, 2013, 166 (03) : 139 - 152
  • [33] Shear behaviour of steel fibre reinforced self-consolidating concrete beams based on the modified compression field theory
    Ding, Yining
    Zhang, Fasheng
    Torgal, Fernando
    Zhang, Yulin
    COMPOSITE STRUCTURES, 2012, 94 (08) : 2440 - 2449
  • [34] Seismic behaviour of steel coupling beams linking reinforced concrete shear walls
    Park, WS
    Yun, HD
    ENGINEERING STRUCTURES, 2005, 27 (07) : 1024 - 1039
  • [35] Comparison of shear behaviour of concrete beams reinforced with GFRP bars and steel bars
    Halvonik, Jaroslav
    Borzovic, Viktor
    Laniova, Dagmar
    STRUCTURES, 2022, 43 : 657 - 668
  • [36] Shear capacity of steel fibre reinforced concrete coupling beams using conventional reinforcements
    Cai, Gaochuang
    Zhao, Jun
    Degee, Herve
    Vandoren, Bram
    ENGINEERING STRUCTURES, 2016, 128 : 428 - 440
  • [37] Shear strength and deformation of steel fibre-reinforced concrete beams after fire
    Antonius
    Karlinasari, Rinda
    Purwanto
    Widhianto, Aref
    ADVANCES IN CONCRETE CONSTRUCTION, 2020, 10 (02) : 105 - 111
  • [38] Assessment of shear-resisting mechanisms of steel-fibre-reinforced concrete beams
    Negi, Bichitra Singh
    Jain, Kranti
    PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-STRUCTURES AND BUILDINGS, 2021, 176 (09) : 649 - 665
  • [39] Shear retrofitting of reinforced concrete beams with steel fiber reinforced concrete
    Ruano, Gonzalo
    Isla, Facundo
    Pedraza, Rodrigo Isas
    Sfer, Domingo
    Luccioni, Bibiana
    CONSTRUCTION AND BUILDING MATERIALS, 2014, 54 : 646 - 658
  • [40] Behaviour of fibre-reinforced concrete beams on grade
    Briggs, Michael A.
    Thompson, Adrian
    Valsangkar, Arun J.
    INTERNATIONAL JOURNAL OF PHYSICAL MODELLING IN GEOTECHNICS, 2016, 16 (04) : 152 - 159