Development of a CLYC-based wide dose rate range portable neutron-gamma detector

被引:2
|
作者
Huang, Yuliang [1 ,2 ]
Zhao, Keqing [1 ,2 ]
Shan, Chenyu [3 ]
Feng, Changqing [1 ,2 ]
Wang, Yichao [1 ,2 ]
Wang, Ziqi [1 ,2 ]
Chang, Kang [3 ]
Liu, Feng [3 ]
Xie, Wenzhang [3 ]
Liu, Shubin [1 ,2 ]
机构
[1] Univ Sci & Technol China, State Key Lab Particle Detect & Elect, Hefei 230026, Peoples R China
[2] Univ Sci & Technol China, Dept Modern Phys, Hefei 230026, Peoples R China
[3] China Nucl Power Technol Res Inst Co Ltd, Beijing, Peoples R China
关键词
Portable detector; CLYC; Gamma-ray; Neutron; Mixing field detection; SCINTILLATION PROPERTIES; DISCRIMINATION;
D O I
10.1016/j.apradiso.2024.111629
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
This paper describes the development of a portable neutron-gamma detector for environmental radiation monitoring based on the CLYC crystal. It can function as a gamma spectrometer, gamma dosimeter, and thermal neutron counter. The upper measurement limit of gamma dose rate is approximately 6 mSv/h by using the proposed current mode in CLYC crystal and PMT. Meanwhile, the detector has a gamma energy resolution of 4.86% at 662 keV, and a figure of merit (FOM) of 3.32 +/- 0.04 for gamma and neutron pulse shape discrimination. In the initial phase of applications, the detector was used to measure the gamma and neutron radiation levels around the beamline of the associated Proton beam Experiment Platform (APEP) and R-dump room at the China Spallation Neutron Source (CSNS).
引用
收藏
页数:12
相关论文
共 36 条
  • [11] Study on Gamma Spectrometer Design of Wide Dose Rate Range
    Zhou, Huanyin
    Li, Jianwei
    Xu, Feiyan
    Xie, Yanhui
    Hu, Jiewei
    Wu, Feifei
    2024 5TH INTERNATIONAL CONFERENCE ON COMPUTER ENGINEERING AND APPLICATION, ICCEA 2024, 2024, : 837 - 840
  • [12] A WIDE RANGE GAMMA-RAY DOSE RATE METER
    SRDOC, D
    HEALTH PHYSICS, 1966, 12 (12): : 1803 - +
  • [13] A portable and wide energy range semiconductor-based neutron spectrometer
    Hoshor, C. B.
    Oakes, T. M.
    Myers, E. R.
    Rogers, B. J.
    Currie, J. E.
    Young, S. M.
    Crow, J. A.
    Scott, P. R.
    Miller, W. H.
    Bellinger, S. L.
    Sobering, T. J.
    Fronk, R. G.
    Shultis, J. K.
    McGregor, D. S.
    Caruso, A. N.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 803 : 68 - 81
  • [14] Neutron-gamma pulse shape discrimination for organic scintillation detector 2D CNN based classification
    Karmakar, Annesha
    Pal, Anikesh
    Kumar, G. Anil
    Bhavika
    Vivek
    Tyagi, Mohit
    APPLIED RADIATION AND ISOTOPES, 2025, 217
  • [15] A method for determining density based on gamma ray and fast neutron detection using a Cs2LiYCl6 detector in neutron-gamma density logging
    Zhang, Quanying
    Zhang, Feng
    Gardner, Robin P.
    Yan, Huizhong
    Wu, Guoli
    Tian, Lili
    Chen, Qian
    Ti, Yongzhou
    APPLIED RADIATION AND ISOTOPES, 2018, 142 : 77 - 84
  • [16] Design of a portable dose rate detector based on a double Geiger-Mueller counter
    Wang, Peng
    Tang, Xiao-Bin
    Gong, Pin
    Huang, Xi
    Wen, Liang-Sheng
    Han, Zhen-Yang
    He, Jian-Ping
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2018, 879 : 147 - 152
  • [17] A WIDE-RANGE NEUTRON DOSIMETER BASED ON A CR-39 TRACK DETECTOR
    LUSZIKBHADRA, M
    ALBERTS, WG
    DIETZ, E
    GULDBAKKE, S
    MATZKE, M
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1993, 22 (1-4): : 671 - 674
  • [18] DEVELOPMENT AND EVALUATION OF A NEUTRON-GAMMA MIXED-FIELD DOSIMETRY SYSTEM BASED ON A SINGLE THERMOLUMINESCENCE DOSIMETER
    HERMINGHUYSEN, KR
    BLUE, TE
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 353 (1-3): : 420 - 424
  • [19] Development of a Portable 10B-Based 3He Replacement Neutron Detector
    King, Michael J.
    Gozani, Tsahi
    Benetti, Robert
    Hilliard, Donald B.
    Benetti, Bryan
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2013, 60 (02) : 885 - 889
  • [20] DEVELOPMENT OF WIDE-ENERGY RANGE PERSONAL NEUTRON DOSIMETER USING CR-39 TRACK DETECTOR
    OHGUCHI, H
    NAKAMURA, T
    APPLIED RADIATION AND ISOTOPES, 1995, 46 (6-7) : 509 - 510