Ultrasound Derived Inferior Vena Cava Diameter and Collapsibility Index to Predict Central Venous Pressure Prior and After A Fluid Challenge in Spontaneous Breathing Preoperative Patients

被引:0
|
作者
Talreja, Neha Gopal [1 ]
Shetty, Vijay [1 ]
机构
[1] Fortis Hosp Mulund Goregaon Link Rd, Mumbai 400078, Maharashtra, India
关键词
Central venous pressure (CVP); collapsibility index (CI); inferior vena cava (IVC) diameters; passive leg raising (PLR); RIGHT ATRIAL PRESSURE; NONINVASIVE ESTIMATION; EUROPEAN-ASSOCIATION; AMERICAN-SOCIETY; RIGHT-HEART; RESPONSIVENESS; VOLUME; ECHOCARDIOGRAPHY; ULTRASONOGRAPHY; GUIDELINES;
D O I
10.21608/ASJA.2024.250976.1021
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: Central venous pressure (CVP) is indicator of preload and used to determine intravascular volume status. An invasive method such as central venous catheter placement is required in order to measure CVP. However, it is associated with many complications. Instead, sonographic measurement of inferior vena cava (IVC) represents effective and noninvasive method of estimating CVP and recommendations are provided by the American Society of Echocardiography (ASE). There are various methods to calculate and estimate CVP using ultrasound. One of the ultrasonographic (US) technique for obtaining the JVP from a high-resolution B-mode sonogram sequences (US-JVP), recording the changes in IJV-CSA (cross section area) over the cardiac cycle (CC) has been proposed which appears to have potential as an approach for estimating CVP. Patients and Methods: It is a prospective double blinded observational study conducted at tertiary hospital among 40 consenting patients. Results: We found that 27 patients (67.5%) had correct prediction of CVP by USG with measured CVP after transducing central venous catheter at baseline (supine position). Similarly, 19 patients (47.5%) had correct prediction of CVP with measured CVP after passive leg raising. We found that 14 patients (35%) had 10% rise in mean arterial pressure on passive leg raising. We denoted these patients as Responders. We found that both responders and non-responders had poor correlation with CVP prediction. Also IVC diameters and collapsibility index did not predict the fluid responsiveness of the patients. Spearman correlation coefficient was used to study correlation between two quantitative variables. In our study, we found a strong positive correlation between predicted CVP (determined by USG parameters) and measured CVP (determined by transducing central venous catheter on monitor) at baseline (supine position) and after passive leg raising. Multivariate regression analysis was done to find the significant predictor of CVP which was found to be IVC maximum diameter (p value 0.01) determined by USG. Conclusion: Bedside USG in preoperative patients can be used as a simple and reliable method to calculate IVC diameters and collapsibility index to predict CVP. It requires minimal training and correlates well with real time transduced CVP. In our study of 40 patients we aimed to study the ability of the ultrasound guided measurements of the Inferior Vena Cava in predicting the Central Venous Pressure (CVP). A strong positive correlation was found between the predicted CVP and measured/transduced CVP in supine position 8 (baseline) and after passive leg raising. On multivariate regression analysis, the IVC maximum diameter determined by USG was found to be the significant predictor of CVP. No significant correlation was noted between IVC parameters, Collapsibility index and CVP values to predict fluid responsive nature of the patients.
引用
收藏
页数:10
相关论文
共 42 条
  • [41] Assessment of fluid responsiveness using pulse pressure variation, stroke volume variation, plethysmographic variability index, central venous pressure, and inferior vena cava variation in patients undergoing mechanical ventilation: a systematic review and meta-analysis
    Chaves, Renato Carneiro de Freitas
    Barbas, Carmen Silvia Valente
    Queiroz, Veronica Neves Fialho
    Neto, Ary Serpa
    Deliberato, Rodrigo Octavio
    Pereira, Adriano Jose
    Timenetsky, Karina Tavares
    Silva Junior, Joao Manoel
    Takaoka, Flavio
    de Backer, Daniel
    Celi, Leo Anthony
    Correa, Thiago Domingos
    CRITICAL CARE, 2024, 28 (01)
  • [42] Combination of Inferior Vena Cava Diameter, Hepatic Venous Flow, and Portal Vein Pulsatility Index: Venous Excess Ultrasound Score (VEXUS Score) in Predicting Acute Kidney Injury in Patients with Cardiorenal Syndrome: A Prospective Cohort Study
    Bhardwaj, Vimal
    Vikneswaran, Gunaseelan
    Rola, Philippe
    Raju, Siddharth
    Bhat, Rammohan S.
    Jayakumar, Arunkumar
    Alva, Arjun
    INDIAN JOURNAL OF CRITICAL CARE MEDICINE, 2020, 24 (09) : 783 - 789