Pediatric IOL power calculation: Factors and considerations

被引:0
|
作者
Rathod, Aishwarya [1 ]
Khokhar, Sudarshan [1 ]
Rani, Deeksha [1 ]
机构
[1] AIIMS, Dr Rajendra Prasad Ctr Ophthalm Sci, New Delhi, India
关键词
IOL formula; IOL power calculation; ocular biometry; pediatric IOL power; INTRAOCULAR-LENS IMPLANTATION; INFANT-APHAKIA-TREATMENT; CATARACT-SURGERY; VISUAL OUTCOMES; CALCULATION FORMULAS; MYOPIC SHIFT; AXIAL LENGTH; REFRACTIVE OUTCOMES; CONTACT-LENS; 1ST YEAR;
D O I
10.4103/IJO.IJO_1205_24
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
This narrative review aims to compare and document various studies on pediatric intraocular lens (IOL) power calculation, highlighting the differences from adult IOL power calculations and assessing the need for accurate ophthalmic biometry and targeted refraction to improve visual outcomes and reduce amblyopia risk. A comprehensive search of the PubMed database was conducted using keywords such as "pediatric cataract surgery," "IOL power calculation," "ocular biometry," and "IOL formulas." Relevant articles were identified by evaluating titles and abstracts, followed by full-text examination. References were reviewed for thorough coverage. Pediatric eyes pose unique challenges for IOL power calculation due to smaller size, changing axial length, and corneal curvature. Accurate biometry, particularly axial length and keratometry, is crucial. Studies comparing IOL formulas, primarily developed for adults, show varying prediction errors in pediatric cases. Newer-generation formulas such as Barrett's Universal II and Kane demonstrate superior accuracy compared to older formulas (e.g., SRK/T). Undercorrection strategies account for myopic shifts due to eye growth, but consensus on the best formula and target refraction is lacking. Premium IOLs, such as multifocal and toric, offer benefits but require further long-term evaluation. Accurate IOL power calculation is critical for optimal visual outcomes in pediatric cataract surgery. While newer IOL formulas show promise, the unpredictable nature of eye growth and myopic shifts complicates long-term predictions. Premium IOLs offer potential advantages but necessitate careful consideration. Continuous advancements in IOL technology and personalized approaches to target refraction are essential to improve the quality of life of pediatric patients.
引用
收藏
页码:312 / 319
页数:8
相关论文
共 50 条
  • [41] Calculation of iris-claw IOL power for correction of late in-the-bag IOL complex dislocation
    Valentín Huerva
    Francisco J. Ascaso
    Isabel Caral
    Andrzej Grzybowski
    BMC Ophthalmology, 17
  • [42] Calculation of iris-claw IOL power for correction of late in-the-bag IOL complex dislocation
    Huerva, Valentin
    Ascaso, Francisco J.
    Caral, Isabel
    Grzybowski, Andrzej
    BMC OPHTHALMOLOGY, 2017, 17
  • [43] IOL calculation concepts
    Langenbucher, Achim
    ACTA OPHTHALMOLOGICA, 2019, 97
  • [44] Consistent IOL calculation
    Preussner, PR
    Wahl, J
    Lahdo, H
    Findl, O
    OPHTHALMOLOGE, 2001, 98 (03): : 300 - 304
  • [45] COMPUTERIZED IOL CALCULATION
    OLSEN, T
    THIM, K
    CORYDON, L
    ACTA OPHTHALMOLOGICA, 1990, 68 : 37 - 39
  • [46] Monte-Carlo simulation of a thick lens IOL power calculation
    Langenbucher, Achim
    Szentmary, Nora
    Cayless, Alan
    Gatinel, Damien
    Debellemaniere, Guillaume
    Wendelstein, Jascha
    Hoffmann, Peter
    ACTA OPHTHALMOLOGICA, 2024, 102 (01) : e42 - e52
  • [47] THE EFFECT OF STANDARDIZED KERATOPLASTY TECHNIQUE ON IOL POWER CALCULATION FOR THE TRIPLE PROCEDURE
    MATTAX, JB
    MCCULLEY, JP
    ACTA OPHTHALMOLOGICA, 1989, 67 : 24 - 29
  • [48] Estimation of Posterior Corneal Power for IOL Calculation After Myopic LASIK
    Srivannaboon, Sabong
    Rakpanichmanee, Thanapat
    Cheng, Arthur C. K.
    Fam, Han-Bor
    JOURNAL OF REFRACTIVE SURGERY, 2008, 24 (09) : 946 - 952
  • [49] Corneal Anterior Power Calculation for an IOL in Post-PRK Patients
    De Bernardo, Maddalena
    Iaccarino, Stefania
    Cennamo, Michela
    Caliendo, Luisa
    Rosa, Nicola
    OPTOMETRY AND VISION SCIENCE, 2015, 92 (02) : 190 - 195
  • [50] IOL Power Calculation in an Unusual Long Fellow Eye: A Case Report
    Camellin, Umberto
    Franchina, Francesco
    Meduri, Alessandro
    Aragona, Pasquale
    OPTICS, 2023, 4 (03): : 396 - 401