OXYTETRACYCLINE ELECTROCHEMICAL DETERMINATION AT DISPOSABLE PENCIL GRAPHITE ELECTRODE

被引:0
|
作者
Preda, Daniel [1 ]
Matei, Anca [2 ]
Cheregi, Mihaela-Carmen [2 ]
Iorgulescu, Emilia-Elena [2 ]
Radu, Gabriel-Lucian [1 ]
David, Gabriela-Iulia [2 ]
机构
[1] Natl Univ Sci & Technol POLITEHN Bucharest, Dept Chem Engn & Biotechnol, Bucharest, Romania
[2] Univ Bucharest, Fac Chem, Dept Analyt Chem & Phys Chem, Bucharest, Romania
关键词
oxytetracycline; electroanalysis; disposable electrode; voltammetry; ELECTROPHORESIS-MASS SPECTROMETRY; RESIDUES; TETRACYCLINE;
D O I
暂无
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Oxytetracycline (OTC) is a broad-spectrum antibiotic that belongs to the tetracycline class. It is utilized in both human and veterinary medicine to treat a variety of bacterial infections and as a feed additive for animals. Therefore, there is an increased need in the development of simple, rapid and reliable methods for this antibiotic determination in various matrices. This work presents OTC voltammetric analysis at the disposable, cheap pencil graphite electrode (PGE). The voltammetric response was investigated at different types of working electrodes emphasized that the highest sensitivity was exhibited by PGE using HB type pencil leads. Electrochemical pretreatment of the PGE did not bring any improvement in OTC oxidation signal. The effect of solution pH on the voltammetric behavior of OTC was examined using both cyclic voltammetry (CV) and differential pulse voltammetry (DPV) in Britton-Robinson Buffer (BRB) solutions with pH values ranging from 2.00 to 11.00. The oxidation was irreversible, resulting a diffusion- controlled process that was dependent on pH and involved an equal number of electrons and protons. The highest signal was observed at pH 4.56. Applying DPV on HB PGE, the oxidation peak of the analyte increased linearly with its concentration in the range 1.00 x 10-6 to 3.60 x 10-4 mol/L. The method's limit of detection was calculated to be 6.80 x 10-7 mol /L OTC. The applicability of the developed DPV method using HB PGE was tested by quantification the antibiotic from veterinary pharmaceutical preparations. Employing the standard addition method, the obtained mean recovery was 103.12%.
引用
收藏
页码:135 / 146
页数:12
相关论文
共 50 条
  • [21] Disposable Pencil Graphite Electrode for Diosmin Voltammetric Analysis
    David, Iulia Gabriela
    Oancea, Alexandra-Gabriela
    Buleandra, Mihaela
    Popa, Dana Elena
    Iorgulescu, Emilia Elena
    Ciobanu, Adela Magdalena
    MICROMACHINES, 2021, 12 (04)
  • [22] Disposable Pencil Graphite Electrode for Ciprofloxacin Determination in Pharmaceutical Formulations by Square Wave Voltammetry
    Alves, Guilherme Figueira
    Lisboa, Thalles Pedrosa
    de Faria, Lucas Vinicius
    de Farias, Davi Marques
    Costa Matos, Maria Auxiliadora
    Matos, Renato Camargo
    ELECTROANALYSIS, 2021, 33 (02) : 543 - 549
  • [23] Electrochemical Characterization and Determination of Tramadol drug using Graphite Pencil Electrode
    Patil, Deepa G.
    Gokavi, Naveen M.
    Bagoji, Atmanand M.
    Nandibewoor, Sharanappa T.
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2016, 8 (01): : 78 - 91
  • [24] Electrochemical characterization and determination of paclitaxel drug using graphite pencil electrode
    Gowda, Jayant I.
    Nandibewoor, Sharanappa T.
    ELECTROCHIMICA ACTA, 2014, 116 : 326 - 333
  • [25] SIMPLE VOLTAMMETRIC ANALYSIS OF SULFAMETHOXAZOLE AT A DISPOSABLE PENCIL GRAPHITE ELECTRODE
    David, Iulia Gabriela
    Panait, Andreea Laura
    Buleandra, Mihaela
    Popa, Dana Elena
    Cheregi, Mihaela C.
    REVUE ROUMAINE DE CHIMIE, 2022, 67 (03) : 177 - 183
  • [26] Novel voltammetric investigation of dipyridamole at a disposable pencil graphite electrode
    David, Iulia Gabriela
    Iordache, Lorelei
    Popa, Dana Elena
    Buleandra, Mihaela
    David, Victor
    Iorgulescu, Emilia-Elena
    TURKISH JOURNAL OF CHEMISTRY, 2019, 43 (04) : 1109 - 1122
  • [27] Voltammetric Investigation of Ferulic Acid at Disposable Pencil Graphite Electrode
    David, Iulia Gabriela
    Popa, Dana Elena
    Buleandra, Mihaela
    Codreanu, Silvia Nicoleta
    Croitoru, Lorelei
    Iordache, Laura Andreea
    Noor, Hassan
    MICROMACHINES, 2023, 14 (10)
  • [28] Preparation of Activated Disposable Pencil Graphite Electrode for the Selective and Sensitive Determination of a Fluoroquinolone Antibiotic: Levofloxacin
    Gurbuz, Mustafa
    Ozcan, Ayca Atilir
    Ozcan, Ali
    CURRENT PHARMACEUTICAL ANALYSIS, 2018, 14 (03) : 247 - 254
  • [29] Electrochemical determination of anticancer drug fulvestrant at dsDNA modified pencil graphite electrode
    Dogan-Topal, Burcu
    Ozkan, Sibel A.
    ELECTROCHIMICA ACTA, 2011, 56 (12) : 4433 - 4438
  • [30] Electrochemical Determination of Paracetamol by a Novel Derivative of Formazan Modified Pencil Graphite Electrode
    Gorcay, Hakan
    Turkoglu, Gulsen
    Sahin, Yucel
    Berber, Halil
    IEEE SENSORS JOURNAL, 2014, 14 (08) : 2529 - 2536