High-efficient white blood cell separation from whole blood using cascaded inertial microfluidics

被引:3
|
作者
Cha, Haotian [1 ]
Kang, Xiaoyue [2 ]
Yuan, Dan [2 ]
de Villiers, Belinda [3 ]
Mak, Johnson [3 ]
Nam-Trung Nguyen [1 ]
Zhang, Jun [1 ,4 ]
机构
[1] Griffith Univ, Queensland Micro & Nanotechnol Ctr, Nathan, Qld 4111, Australia
[2] Univ Queensland, Sch Mech & Min Engn, Brisbane, Qld 4072, Australia
[3] Griffith Univ, Inst Glyc, Gold Coast, Australia
[4] Griffith Univ, Sch Engn & Built Environm, Nathan, Qld 4111, Australia
基金
澳大利亚研究理事会;
关键词
HIGH-THROUGHPUT; PLASMA; CLASSIFICATION; EXTRACTION; CHIP;
D O I
10.1016/j.talanta.2024.127200
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
White blood cells (WBCs) are a crucial component of the human immune system. WBCs contain invaluable information about the health status of the human body. Therefore, separating WBCs is indispensable for the diagnosis of many diseases in clinical setting. The low ratio of WBCs to red blood cells in whole blood has made the isolation of WBCs challenging. As the conventional single-stage microfluidic technology cannot provide sufficient separation purity. We used a cascaded inertial microfluidic chip by consecutively connecting two sinusoidal channels to enhance the purity of WBCs after single processing. The improvement was in part due to the diversion of the sample at the end of the first stage separation, resulting in a lower flow rate in the second stage of processing within the cascaded device. We embedded concave micro-obstacles in sinusoidal channels to adjust their effective working flow rate range and enable the proper operation of both channels simultaneously. Using polystyrene beads mixture (5 and 10 mu m) with a primary ratio of 1000 to 1, a single processing step through our cascaded chip improved the purity of 10-mu m particles with more than three orders of magnitude of enrichment (from 0.08 % to 99.83 %) with a flow rate of 560 mu L/min (Re = 77). Using diluted whole blood ( x 1/10), we achieved 307-fold enrichment of WBCs (0.14 %-43.017 %) in a single process which was accompanied with similar to 3 orders of magnitude background removal of RBCs (from 4.8 x 10(8) to 5.7 x 10(5) counts/mL). This cascaded manner chip has the capacity to achieve high-efficiency separation of blood cells for clinical diagnosis.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] High-Yielding Separation and Collection of Plasma from Whole Blood Using Passive Filtration
    Baillargeon, Keith R.
    Murray, Lara P.
    Deraney, Rachel N.
    Mace, Charles R.
    ANALYTICAL CHEMISTRY, 2020, 92 (24) : 16245 - 16252
  • [42] Design and Performance Analysis of Spiral Microchannels for Efficient Particle Separation Using Inertial Microfluidics
    Ozyilmaz, Eda
    Ilis, Gamze Gediz
    MICROMACHINES, 2025, 16 (03)
  • [43] Functional inactivation of human white blood cells in whole blood products using the Mirasol system for whole blood
    Fast, L.
    Marschner, S.
    DiLeone, Gilbert
    Doane, S.
    Fitzpatrick, C.
    Goodrich, R.
    TRANSFUSION, 2008, 48 (02) : 160A - 160A
  • [44] Spiral Inertial Microfluidic Devices for Continuous Blood Cell Separation
    Nivedita, Nivedita
    Ligrani, Phillip
    Papautsky, Ian
    MICROFLUIDICS, BIOMEMS, AND MEDICAL MICROSYSTEMS X, 2012, 8251
  • [45] Fetal cells from maternal blood: High density gradient versus magnetic separation from whole blood
    Bohmer, RM
    Stroh, H
    Bianchi, DW
    AMERICAN JOURNAL OF HUMAN GENETICS, 2002, 71 (04) : 564 - 564
  • [46] Robust and efficient separation of white blood cells from blood using a microfluidic chip with a pair of linearly tapered crossflow filter arrays
    Huang, Yuanding
    Chen, Ping
    Niu, Meng
    Peng, Weng Kung
    MICROCHIMICA ACTA, 2025, 192 (01)
  • [47] FLOW CYTOMETRY FOR WHITE BLOOD-CELL COUNTS IN WHOLE-BLOOD AND BLOOD COMPONENTS
    RADTKE, H
    LINDENAU, S
    HOLBACH, B
    NEUMANN, S
    KIESEWETTER, H
    INFUSIONSTHERAPIE UND TRANSFUSIONSMEDIZIN, 1995, 22 : 112 - 114
  • [48] A capillary dielectrophoretic chip for real-time blood cell separation from a drop of whole blood
    Liao, Shu-Hsien
    Chang, Ching-Yu
    Chang, Hsien-Chang
    BIOMICROFLUIDICS, 2013, 7 (02):
  • [49] Microfluidic Pipette Tip for High-Purity and High-Throughput Blood Plasma Separation from Whole Blood
    Kim, Byeongyeon
    Oh, Sein
    You, Dongwon
    Choi, Sungyoung
    ANALYTICAL CHEMISTRY, 2017, 89 (03) : 1439 - 1444
  • [50] Rapid separation of bacteria from primary nasal samples using inertial microfluidics
    Shrestha, Jesus
    Bazaz, Sajad Razavi
    Ding, Lin
    Vasilescu, Steven
    Idrees, Sobia
    Soderstrom, Bill
    Hansbro, Philip M.
    Ghadiri, Maliheh
    Warkiani, Majid Ebrahimi
    LAB ON A CHIP, 2022, 23 (01) : 146 - 156